Search

3960 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 553
    Names
    Loading...
  • 132
    Manufacturer
    Loading...
  • 59
    Made in
    Loading...
  • 108
    Additional
    Loading...
View:
3960 products
Liquid thermostat THERMOTEST-100
Liquid thermostat THERMOTEST-100
The operating temperature range is -30...+105 °C. The stability and uniformity of the temperature in the working bath is not worse than ± 0.01 ° C without the use of a leveling unit. Bath volume 13 l Overall dimensions 450x700x810 mm The open part of the bath is 90 mm Bath depth 430 mm Weight 70 kg Power consumption 3.5 kW
Produced in: Tomsk
Measuring Cylinder 3-100-2
Measuring Cylinder 3-100-2
from 130 ₽
Designed for dispensing volatile liquids. The applied scale of brown or white colors is completely resistant to any influences. TU 9464-013-52876351-2014, GOST 1770-74, pack of 5 pieces, MiniMedProm Manufactured according to specifications 9464-013-52876351-2014 in accordance with the technical requirements of GOST 1770-74. The products are made of chemical laboratory glass according to GOST 21400. Version 3, accuracy class 2. RU No. RZN 2016/4740 of 10/25/2021
MiniMed
Suponevo
Produced in: Bryansk region
Hinged cabinet LAB-M NSH-1 80.35.70
Hinged cabinet LAB-M NSH-1 80.35.70
Furniture for laboratory work. Mounted storage cabinet Length, mm: 800 Depth, mm: 350 Height, mm: 700 PACKAGE CONTENTS the case is white melamine with a thickness of 16 mm, the ABS edge is dark gray two compartments. The left compartment with a swing door, the right one is open the facade of the left compartment is white melamine with a dark gray ABS edge in the right compartment there is 1 built–in shelf, in the left compartment there is 1 easily removable shelf with the possibility of rearrangement at 5 levels in height the permissible load on the shelf is 20 kg.
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Exhaust cabinet LAB-M SHV ME 90.74.210 TR
Exhaust cabinet LAB-M SHV ME 90.74.210 TR
Furniture for laboratory work. All-metal exhaust cabinet Working surface: Trespa TopLab 6mm, on a substrate of wood-containing material (plywood 15mm, melamine 16mm). Overall dimensions: Length, mm: 900 Depth, mm: 740 Height, mm: 2100 equipment Working box front anti–spill side - acid–resistant polished stainless steel AISI 316 housing - metal painted with white powder paint (RAL 9016) guide posts – aluminum profile painted with dark gray powder paint (RAL 7011) 2 dependent lifting screens – tempered glass in aluminum frames, lifting 0-710mm, do not change the dimensions of the cabinet when lifting.
LOIP
Saint Petersburg
Produced in: Saint Petersburg
AD-42IP Acoustic Flaw Detector
AD-42IP Acoustic Flaw Detector
from 442 500 ₽
It is especially effective for use in products made of composite materials (including with honeycomb filler). Distinctive features: The AD-42 IP is a compact acoustic system sensitive to changes in mechanical impedance caused by product defects. The indication of the device indicates that there are voids, non-adhesives, delaminations or changes in the structure of composite materials (including with honeycomb filler and laminated plastics) under the sensor. The device is used to monitor various materials and their combinations. The energy consumption of the unit is low because the converter is switched on when the sensor is placed on the monitored product. Being light enough, the device allows you to perform monitoring in hard-to-reach places or in confined spaces. The results of the control can be stored in the built-in non-volatile memory and transferred to a PC. Converters Options: - 3 types of converters for various tasks Emitters: - 1 or 2 on each converter Switching-on: - The converters are switched on when they are placed on a controlled object. Technical characteristics: Weight, kg: 0.73 Dimensions, mm: 210x150x70 Power supply: 4 AA batteries Work without recharging the battery, h: 8 Battery discharge visual indication The defect alarm is visual on the converter and audible on the instrument panel (or) in headphones.
Produced in: Moscow
Laboratory electric furnace CHO-40
Laboratory electric furnace CHO-40
from 347 688 ₽
Designation SNO-40 Volume, l 40 The material of the working chamber is ceramic Heating 4 sides Power consumption, W, max 10000 Minimum operating temperature, 0C 100
Produced in: Tula
3VVN2-50 Water ring vacuum pump
3VVN2-50 Water ring vacuum pump
The 3VVN2-50(H) water ring vacuum pump is not intended for use in fire and explosion hazardous industries. The 3VVN2-50(H) vacuum water ring pump is manufactured in the climatic version of UHL 4 and O4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, meets the requirements of technical specifications TU 3648-053-00218526-2013, designed and manufactured taking into account the requirements of GOST R 52615-2006.
Produced in: Kazan
The bath for checking ariometers VPA
The bath for checking ariometers VPA
Allows you to simultaneously place up to 4 hydrometers and a thermometer. A low-temperature liquid thermostat is additionally required to ensure the temperature of the calibration liquid of 20 ±0.05 °. Overall dimensions 500x380x650 mm The open part of the bath is 135 mm Bath depth 490 mm Weight 27 kg
Produced in: Tomsk
Vacuum tube MiniMed with coagulation activator and separation gel, 5ml,13*100 mm, yellow-orange, PET,pack.100,
Vacuum tube MiniMed with coagulation activator and separation gel, 5ml,13*100 mm, yellow-orange, PET,pack.100,
from 1 210 ₽
Test tubes are used for blood sampling in biochemistry and immunology. During centrifugation, the gel forms a strong barrier for 48 hours between the clot and the serum. The gel tubes must be centrifuged no later than 2 hours after blood collection. Material for research............... blood serum Scope of application............................ serum research in biochemistry, immunology Centrifugation.............................. 1500-2000 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Laboratory flask
Laboratory flask
Designed for filtration, evaporation, distillation, distillation, distillation and synthesis in laboratory conditions. Variants of execution: P-2-100-22 P-2-100-34 TU 9464-019-29508133-2015 P-2-1000-42 TU 9464-019-29508133-2015 P-2-2000-50 TU 9464-019-29508133-2015 P-2-250-34 TU 9464-019-29508133-2015 P-2-3000-50 TU 9464-019-29508133-2015 P-2-4000-50 TU 9464-019-29508133-2015 P-2-50-22 TU 9464-019-29508133-2015 P-2-500-34 TU 9464-019-29508133-2015 P-2-5000-50 TU 9464-019-29508133-2015 P-2-6000-65 TU 9464-019-29508133-20155
MiniMed
Suponevo
Produced in: Bryansk region
Whiteness meter BARS
Whiteness meter BARS
1 supp.
The principle of operation is based on measuring the zonal reflection coefficient of a compacted-smoothed flour surface using a built-in standard. The laboratory white meter BARS is approved as a type of measuring instruments and is registered in the State Register of Measuring Instruments under No. 78409-20. All manufactured devices undergo primary verification and have the appropriate certificate. Due to the two-channel design of the device (the presence of two photometric units and a cuvette with two cells), parallel measurements of the whiteness of one flour sample are carried out simultaneously, the average value is calculated automatically, which significantly reduces the time of analysis. The sealing of the flour sample with a fixed force and pressing against the optical windows ensures the same measurement conditions and eliminates the influence of a subjective factor on the result. The automatic adjustment system based on the built-in standard allows to ensure long-term stability of the device without the need for manual adjustment. During operation, the standard is set to the working position by an additional drive. Mechanical damage or loss of the standard is excluded. The output to the operating mode is no more than 30 seconds. The determination of whiteness is carried out in 15 seconds. To determine the whiteness of flour, the operator needs to fill 2 compartments of the cuvette with the test sample of flour, install the cuvette in the device and start the measurement process. All the results of the whiteness definitions are stored in the archive. The operator has the opportunity to view the electronic measurement log.
GK EKAN
Saint Petersburg
Produced in: Saint Petersburg