Wall-mounted low table LAB-PRO SPCn 90.80.75 KG-ESS
Wall-mounted low table LAB-PRO SPCn 90.80.75 KG-ESS
BASIC EQUIPMENT The base is a collapsible frame made of rectangular steel profile, painted with powder paint (RAL 7035) with the texture of shagreen leather Hidden fasteners Two easily removable rear screens (RAL 7035) and one non-removable (RAL 5023) Rear side boxes Adjustable supports (0-40 mm)
LOIP
Saint Petersburg
Produced in: Saint Petersburg
ND-1000 High vacuum diffusion pump
ND-1000 High vacuum diffusion pump
The working condition of the ND-1000 diffusion pump depends on the temperature of the working fluid in the pump boiler. During the initial filling, it is recommended to fill the maximum volume of the working fluid. The working fluid is "VACMA OIL 500" vacuum oil (under technical specifications TU 19.20.29-061-00218526-2019). The total amount of working fluid in the ND-1000 diffusion pump is a maximum of 23 liters, a minimum of 16 liters. The viewing window for visual inspection of the working fluid has marks of its maximum and minimum amounts. During normal operation of the pump, the level of the working fluid practically does not change. The temperature of the working fluid when the pump is operating at the maximum residual pressure is about 240°C to 255°C. It is recommended to monitor the operation of heaters in the ND-1000 diffusion pump using two temperature sensors. The temperature sensor must be installed in a special radiator socket above the heater. In the event that there is a loss of working fluid and an increase in the temperature of the radiators to 360 0C for the ND-1000 diffusion pump, the temperature sensor must give the command to automatically turn off the heaters. The subsequent activation of the pump heaters should not be automatic and should be performed only after cooling the system. Water at the inlet to the cooling systems of the housing and the oil reflector must be supplied with a pressure of 0.3 MPa (3 kgf/cm2) to 0.5 MPa (5 kgf/cm2) and a temperature of plus 4°C to plus 25°C. The recommended cooling water consumption for the housing is 1500 l/h, for the oil reflector 150 l / h and is regulated by the outlet water temperature, which should not exceed plus 40°C. The water drain should be free (with a jet break).
Produced in: Kazan
PLKS-02 Heating plate
PLKS-02 Heating plate
Laboratory heating plate with two heating sections and with the possibility of setting the temperature and heating time. The heating platforms are made of glass-ceramic. The size of the total heating surface: 440x284 mm. Heating temperature: 40-500 oC.
Produced in: Tomsk
Table top to table-cabinet LAB-PRO RP 90.80 SS
Table top to table-cabinet LAB-PRO RP 90.80 SS
Table top to the wall table on the support pedestal Material: STEEL (n/W steel with a side) Length, mm: 900 Depth, mm: 800
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Universal energy dispersive X-ray fluorescence spectrometer BRA-135F
Universal energy dispersive X-ray fluorescence spectrometer BRA-135F
The XRF analyzer BRA-135F is an energy dispersive spectrometer which can simultaneously determine the presence of up to twenty chemical elements - from 9F to 92U - in the analyzed sample. Samples can be in liquid, solid, powdered or deposited on a substrate. The analyzer captures concentrations from tenths of mg/kg. The model BRA-135F performs quantitative/semi-quantitative spectral analysis of steel and alloys. It also performs spectral analysis of oil, petroleum and other petroleum products, detecting in their composition even the smallest concentrations of impurities of various metals. The vacuum sample chamber and ultra-slim detector inlet provides a low detection limit in the range of light elements from 9F to 17Cl. The high-performance silicon drift detector (SDD) with an energy resolution of less than 135eV allows the separation of spectral lines of almost all elements, which makes the analysis of complex multicomponent substances (high-alloy steels, precision alloys, polymetallic ores, etc.) possible.
Burevestnik
Kolomyagi
Produced in: Saint Petersburg
Central Heating Unit Kit
Central Heating Unit Kit
The kit is designed to control the temperature and pressure of the coolant and archive the measured results for further documentation and analysis. The main purpose of the kit is to control the coolant parameter, monitor the pressure and pressure drop between the supply and return pipelines, and fix hydraulic shocks. Features of the CTP kit The CTP kit allows you to control the parameters of the coolant supply, temperature and pressure. The kit consists of a four-channel meter-recorder, which allows you to store 15,000 values in memory for each channel with an interval of 5 seconds. up to several hours, which allows you to take measurements and store data for up to 1 year. The CTP kit allows you to monitor temperature and pressure around the clock throughout the year, and if necessary, for a longer period. With the help of the CTP kit, we see all the dynamics of the development of the situation of changes in temperature and pressure of the coolant, including weekends (crimping, stopping, starting the heating network, operating modes). The kit allows you to increase the responsibility of personnel for compliance with technological regimes. There is a real-time indication that allows personnel to monitor the parameters of the supplied coolant. A set of TTP is usually installed at the border of responsibility, i.e. at the point where, according to the contract, the supplier is obliged to supply a certain amount of coolant with a specific temperature and pressure parameters.
Produced in: Kolomna, Moscow region
UCHX2-78
UCHX2-78
Basic properties: Wide frequency range; Sufficiently large output power; High level of suppression of side harmonics of the input signal; Low phase noise value; Relatively simple technical solutions: - synchronization and frequency stabilization, - stabilization and adjustment of the output power level, - implementation of amplitude and frequency modulation modes; Do not require external bias diodes. Operating conditions: Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical characteristics Input/output frequency range, GHz 26,78-39,17 / 53,57-78,33 Losses (max.), dB 15 Input power level, dBm 15-21 Unevenness of output power (Rvh. = 20 dBm), dB ± 2.0 The level of parasitic harmonics of the input signal at the output (min.), dBn 20 Output VSWR (max.) 2.0 Connector type: • Input Coax. 2.4/1.0 mm (plug/socket) • Output Waveguide 3,759x1,88 mm (50-75GGo) Overall dimensions, mm 26x20x20 Weight, g 50
Produced in: Moscow
Trace Searcher Success AG-308.60N
Trace Searcher Success AG-308.60N
from 205 800 ₽
A trace searching kit for finding underground utilities (cable lines, metal pipelines, and other communications made of conductive materials). The kit includes a receiver in the form of a monoblock with LED indication, as well as a generator with increased power up to 180 watts and a range of up to 5 km. Connection to the desired route is possible both by contact and contactless method.
Produced in: Kolomna, Moscow region
 Magnetometer - Measuring Residual Magnetization ION-3701 Conveyor
Magnetometer - Measuring Residual Magnetization ION-3701 Conveyor
It is a modern high-precision device (a variant of the ION-3701 device) and used for a wide range of tasks in areas where it is necessary to determine the magnitude of the magnetic field and residual magnetization in shop conditions, on the conveyor, during acceptance and inspection of parts and workpieces. It is equipped with a three-dimensional magnetic field sensor and has outstanding technical characteristics and extensive functionality.
NPP "ELEKTRONNYE PRIBORY"
Naberezhnye Chelny
Produced in: Tatarstan, Naberezhnye Chelny
Muffle furnace LF-9/11-G1
Muffle furnace LF-9/11-G1
Design features: Durable ceramic muffle; Closed heaters on four sides of the chamber; Microprocessor temperature controller; Conveniently located control panel and bright LED display; Ease of management and control; LED indicators of heater operation and protection operation; Automatic shutdown of heating when opening the door; The door opens up and faces the user with the cold side; Alarm when the current temperature exceeds the limits of the permissible range; Highly efficient thermal insulation of the housing; The furnace body is made of high-quality sheet steel and painted with heat-resistant powder paint. Technical specifications: Maximum heating temperature, °C +1100 Temperature stability in steady-state thermal mode, °C ± 10 Warm-up time to maximum temperature, no more than 120 min Dimensions of the working chamber, WxHxD, not less than 200x150x290 mm Overall dimensions, WxHxD, not more than 525x625x620 mm Rated supply voltage, 220 V Rated power, W 5500
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Vacuum drying cabinet with automatic control SNVS-210/5
Vacuum drying cabinet with automatic control SNVS-210/5
The series is designed for heat treatment according to pre-created programs. The presence of remote control and a number of software options allows you to use the product for long-term heat treatment modes. Vacuum drying cabinets can be used for: - gentle drying of thermo- and oxygen-sensitive substances, such as food, medicinal, cosmetic products; - complete removal of residual moisture from heat-sensitive components with a complex shape, such as components of electronic equipment, jewelry, watches and other precision mechanics; - removal of air when filling the molds with a compound, followed by solidification at a given temperature; - removing air from the product and replacing it with another necessary gas medium; - tempering, annealing or aging of metals with an appropriate processing temperature in a vacuum or protective environment; - drying of products after washing in flammable solvents (special version); - testing devices under low pressure conditions under various temperature conditions.
Produced in: Tula
MT-15 liquid thermostat
MT-15 liquid thermostat
The operating temperature range is +20...+150 °C. Stability and uniformity of temperature in the working bath is not worse than ± 0.02 °C Bath volume 20 l Overall dimensions 500x370x610 mm The open part of the bath is 230x280 mm Bath depth 190 mm Weight 25 kg Power consumption 2.2 kW
Produced in: Tomsk