Search

3941 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 550
    Item names
    Loading...
  • 132
    Manufacturer
    Loading...
  • 59
    Made in
    Loading...
  • 109
    Additional
    Loading...
View:
3941 products
Mounted shelf LAB-1200 NSv
Mounted shelf LAB-1200 NSv
Furniture for laboratory work. Mounted shelving Length, mm: 1200 Depth, mm: 330 Height, mm: 690 PACKAGE CONTENTS case – melamine 16mm thick 1 built-in shelf suspension fasteners included
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Software and hardware complex with a set of sensors for physics classrooms
Software and hardware complex with a set of sensors for physics classrooms
The software and hardware complex with a set of sensors for physics classrooms is designed to measure physical quantities during demonstration work on various sections of physics, as well as to perform experimental work on physics. The set of units of the measuring system is compatible with a PC, has software with an instruction manual. The sensor kit includes 10 sensors for measuring the following physical quantities: - temperature sensor DTV-1 (measuring range -200C + 1100 S); - air humidity sensor DTV-1 (measuring range 10-100%); - pressure sensor DD-1 (measuring range 0-700 kPa); - acceleration sensor DUIMP-1 (measuring range - 4 – + 4 g); - permanent magnetic field induction sensor DUIMP-1 (- 8 – + 8 Gs); - illumination sensor DSCH-1 (measuring range 1 -60 000 lux); - distance sensor DR-1 (measuring range 0.04 – 4.0 m); - angular velocity sensor DUPUS-1 (remote) (measuring range 0 – 210 0/ c); - rotation angle sensor DUPUS-1 (measuring range ±3600); - flame temperature sensor DTP-1 (measuring range 100 – 11000 S).
MNIPI
Minsk
Produced in: Belarus, Minsk
Furnace control cabinet SHUP-100-1
Furnace control cabinet SHUP-100-1
Designation SHUP-100-1 Switching power, kW 100 Automatic switch, A 200 Supply network voltage, V/Hz 380
Produced in: Tula
NVDM-250 High vacuum Diffusion Pump
NVDM-250 High vacuum Diffusion Pump
The operation of the NVDM-250 diffusion pump is based on the capture and transfer of the pumped gas by a steam jet flowing from the slit gaps of the steam line nozzles towards the outlet flange. The oil reflector of the NVDM-250 diffusion pump is a flange with a cooling tube passing through it, soldered to a cap located in the center of the flange. The NVDM-250 open-type diffusion pump heater is a metal housing with a ceramic base laid in it with a heating element in the form of a spiral made of nichrome wire. During the operation of the pump, it is necessary to monitor the flow rate and temperature of the cooling water, the level of the working fluid and its temperature. Replacement or refilling of the working fluid depends on the operating mode of the pump (inlet pressure, pumping duration, etc.) and the composition of the pumped medium. Therefore, the time after which the working fluid is replaced or refilled can be from 100 to 1000 or more hours. A large flow rate of the working fluid is observed when the pump is operating in the range of inlet pressures from 6.6 × 10-2 to 13.3 Pa (from 5 ×10-4 to 1 ×10-1 mmHg). Water at the inlet to the cooling systems of the housing and oil reflector must be supplied with a pressure of no more than 0.5 MPa (5 kgf / cm2) and temperature from plus 4°C to plus 25°C. The recommended cooling water consumption is 100+15 l/h and is regulated by the outlet water temperature, which should not exceed plus 400C. The water drain should be free (with a jet break). Not allowed: operation of the pump without water cooling, exceeding the maximum exhaust pressure of 33.3 Pa (0.25 mmHg) The level of the working fluid during operation, at which the parameters of the pump NVDM-250 are provided, must correspond to min 8mm, max 13mm. The volume of the filled working fluid is 0.55 l
Produced in: Kazan
Vacuum tube MiniMed without filler, 7 ml, 13×100 mm, red, PET, pack.100 pcs,Minimed
Vacuum tube MiniMed without filler, 7 ml, 13×100 mm, red, PET, pack.100 pcs,Minimed
from 649 ₽
Tubes without fillers are used for the study of blood serum in biochemical, immunological and serological tests. Material for research............... blood serum Scope of application............................ blood serum research in biochemistry, immunology, serology Centrifugation................................ 1000 - 1500 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Sink LAB-M MO ME 75.60.90 PP
Sink LAB-M MO ME 75.60.90 PP
Furniture for laboratory work. Table-sink on a support pedestal made of metal LAB-M MO ME 75.60.90 PP Width: 750 Depth: 600 Height: 900 Equipment: table top – a single module made of polypropylene. Attention! It is not recommended to use it for work with oil and petroleum products (fuel oil, bitumen, etc.) The inner size of the bowl – 500*400*290 mm
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Spectroanalytical generator "Ball lightning"
Spectroanalytical generator "Ball lightning"
The generator is designed to produce an electric arc and spark discharge in atomic emission spectral analysis installations. The generator is designed specifically for use in spectral analysis of samples of complex composition for simultaneous determination of impurity and alloying components in a wide range of concentrations.
Produced in: Novosibirsk
Multichannel analyzer of atomic emission spectra of MAES
Multichannel analyzer of atomic emission spectra of MAES
The MAES analyzer is a modern means of measuring the intensities of spectral lines and then calculating the concentrations of the elements to be determined.
Produced in: Novosibirsk
Vacuum tube MiniMed with sodium citrate 3.8%,1,8 ml,13*100 mm, blue, PET,pack.100 pcs
Vacuum tube MiniMed with sodium citrate 3.8%,1,8 ml,13*100 mm, blue, PET,pack.100 pcs
from 693 ₽
Vacuum tube MiniMed with sodium citrate 3.8%,1,8 ml,13*100 mm, blue, PET,pack.100 pcs
MiniMed
Suponevo
Produced in: Bryansk region
Muffle furnace LF-7/13-G2
Muffle furnace LF-7/13-G2
Design features: Programmable microprocessor temperature controller; Three programs of ten steps with the ability to set temperature, temperature change rates and exposure time; Manual heating mode with timer with sound notification and auto-off; Durable ceramic muffle; Semi-open heaters on four sides of the chamber; Backlit graphic display; Automatic shutdown of heating when opening the door; Sound and light alarm when the current temperature exceeds the limits of the permissible interval; Highly efficient thermal insulation of the housing; The furnace body is made of high-quality sheet steel and painted with heat-resistant powder paint. Technical specifications: Maximum heating temperature, °C +1300 Temperature stability in steady-state thermal mode, °C ± 10 Warm-up time to the maximum temperature, no more than 120 min Dimensions of the working chamber, WxHxD, not less than 200x110x285 mm Overall dimensions, WxHxD, not more than 505x565x655 mm Rated supply voltage, V 3300
LOIP
Saint Petersburg
Produced in: Saint Petersburg
LA-160 Nitrogen Vacuum trap
LA-160 Nitrogen Vacuum trap
The LA-160 nitrogen filling trap is installed on the inlet flange of the diffusion pump and is designed to reduce the flow of working fluid vapors into the pumped volume by condensing them on the elements of the freezing device cooled with liquid nitrogen.
Produced in: Kazan
Laboratory table low Mod. -600 SLL n "Laminate"
Laboratory table low Mod. -600 SLL n "Laminate"
from 16 178.84 ₽
The table is based on a reinforced O-shaped, collapsible metal frame made of steel shaped tube, rectangular and square cross-sections. The back wall is covered with a metal shield. The table is mounted on adjustable screw bearings, allowing the table to be installed horizontally, regarding the floor unevenness. Frame cover: high-quality powder-polymer paint perfectly protects the base of the table from the effects of any aggressive liquids. The cover of the frame is easily cleaned with disinfectant solutions. The working surface of the Laminate table is a waterproof chipboard plate covered with chemically resistant and heat-resistant plastic.
Produced in: Saint Petersburg