Search

60 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 1
    Names
    Loading...
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • 18
    Applying
    Loading...
  • Names
    Loading...
  • 11
    Manufacturer
  • 10
    Made in
  • 8
    Additional
View:
60 products
P3-34 Electromagnetic field parameter meter
P3-34 Electromagnetic field parameter meter
from 37 500 ₽
It is designed for measuring the electromagnetic energy flux density, the average square values of the electric and magnetic field strengths in the continuous generation mode.
Produced in: Moscow
UShS "Tapirus" with cover and supports
UShS "Tapirus" with cover and supports
from 25 500 ₽
The UShS TapiRus is designed to replace numerous templates and devices used in visual and measuring quality control of welded joints. It is approved as a means of measuring the geometric parameters of welded joints and surface defects during visual and measuring control (VIC) and supplied with verification. It allows you to determine most of the geometric parameters of welded joints and surface defects: the width and convexity of the seam, the depth of the cut, the amount of edge displacement, the angle of the angular seam, the angle of the bevel and the gap, etc. Equipped with supports that allow you to uniquely position the template on a curved surface. To carry out measurements with an error of 0.1 mm, scales with a vernier are applied to the TapiRUS surface. It contains a number of gauges for assessing the smooth transition from the deposited to the base metal, the size of the cathets, radii and angles of cutting edges. Equipped with a probe with a replaceable measuring needle to determine the size of gaps and heights / depressions. The development, preparation for production and manufacture of TapiRus were carried out exclusively in digital format. The latest laser and additive technologies are used in the production of TapiRUS: high-precision laser cutting machines in inert gas; five-axis CNC machining centers; ultra-precise color laser engraving of the entire product assembled; laser stereolithography (SLA) is a technology of layer–by-layer synthesis of a material from a liquid photopolymer. Advantages Easy to install. Accurate positioning along the normal to the surface of the object of control and stability of the position when performing measurements. Functionality. Measurement of most geometric parameters of welded joints and surface defects. Measurement accuracy. The measurement error on the template scales does not exceed 0.1 mm. Modernity. Online calculator ergonomic accessories smart version. More detailed information can be found on the website tapirus.info MEASURED PARAMETERS AND DEFECTS VIC at the stage of input control wall thickness depth of corrosion ulcers on the base metal the depth of corrosion ulcers on the weld the depth of scratches (risks), a bully on the base metal edge bevel angle the amount of blunting geometric parameters of the dent VIC during assembly (preparation for assembly) edge offset withdrawal (angularity) of edges the gap in the cutting the height of the potholders angular displacement VIC in the welding process (surfacing) edge offset height of the root (filling) layer withdrawal (angularity) of edges angular displacement VIC of finished welded joints (structures) edge offset angular displacement the height of the reinforcement of the seam the height of the bulge (when welding elements of different thickness) the width of the reinforcement of the seam withdrawal (angularity) of edges the depth of the sinking between the rollers incomplete filling of the cutting edges scaliness of the seam surface smooth transition undercut depth seam crater depth technical specifications Measured parameter Scale Range,mm Error, mm Depth, mm H 0...20 ±0.1 (in the range 0...10 on), ± 0.5 (in the range over 10...20) Height, mm H 0...6 ±0.1 Width, mm W 0...55 ±0.1 (in the range 0...10 on), ± 0.5 (in the range over 10...20) Clearance, mm N 0...5 ±0.1 Dullness, mm F, G 0...25 ±0.5 Specifications Overall dimensions, mm, no more (without supports) 115x85x15 ± 0.5 (with supports) 115x85x42 ±0.5 Average time to failure, cycles, at least 55,000 Weight, kg, not more than 0.22 Average service life, at least 1 year
Produced in: Moscow
measuring air-thermal installation  ASESH-8-2
measuring air-thermal installation ASESH-8-2
1 supp.
Implements a thermogravimetric (air-thermal) method for determining the mass fraction of moisture, based on measuring the mass of the sample of the analyzed substance before and after drying, followed by calculating the values of the mass fraction of moisture. Air-thermal measuring installations ASESH-8 are registered in the State Register of Measuring Instruments under No. 58526-14, have a certificate of approval of the type of measuring instruments OC.C.31.005 And No. 56847.The installations undergo initial verification and have the appropriate certificate. General characteristics: - The presence of two independent drying chambers. - Possibility of simultaneous determination of humidity of 12 samples: Each drying chamber of the installation consists of 6 independent cells. You can put 2 buckets in each cell. Total capacity of the ASES Installation-8-2 – 24 bucs. - Convenient access to the cells of the drying chamber: On the front side of the cabinet there are four doors for access to the cells. - Natural ventilation: The absence of rotating elements ensures absolute noiselessness of operation and a long service life. - Built-in timer: The ASESH-8-2 installation has 4 timers, by means of which the end of the drying process is monitored in each section with the output of an audible signal and a light indication. - The output to the operating mode is 30 minutes: The power of air-thermal installations is 1200 watts. When entering the operating mode, the power consumption is the same as that of similar cabinets with low power. SCOPE OF DELIVERY : 1. Installation of ASESH-8-2 2. AO-3 cooler 3. Auxiliary accessories 4. Air-heat control unit: 5. Interface unit for connecting a personal computer with a scale (available on request); 6. software for processing and archiving measurements of humidity determination data; The program allows you to: Set the operating temperature in the chambers via a personal computer Set the necessary parameters of the sample drying process according to the selected method Display all current processes (predrying, drying, cooling) and parameters (temperature, time) during the tests. To monitor the process by means of an electronic timer with the output of an audible signal. Record all weighing results. Perform humidity calculations in accordance with standardized methods. To calculate the humidity with pre-drying, the program uses formulas that allow you to get an accurate result. Archive and print test results. According to the test results of FSUE "UNIIM", it is recommended to use a laboratory mill of the BLIZZARD series for sample preparation. SCOPE OF APPLICATION: 1. Crop production, agriculture and forestry. 2. Products of meat, dairy, fish, flour-milling, feed and microbiological industries. 3. Food industry products. 4. Cellulose, paper, cardboard and products made from them. 5. Medicines, chemical and pharmaceutical products and medical products. 6. Building materials. 7. Products of the logging and sawmilling and woodworking industry. 8. Ground, soils, mineral fertilizers. Technical specifications: The measurement range of the mass fraction of moisture, % from 0.5 to 80 Operating temperature range, °C from 45 to 160 The error of setting and maintaining the temperature in the working area, ° C, not more than 2.0 Limits of permissible absolute error, % ± 0.5 Power consumption, V• A, not more than 1200 Overall dimensions, mm 240 × 260 × 640 Overall dimensions of the cell, mm 75 x 40 x 165 (depth) Weight, kg 28.4
GK EKAN
Saint Petersburg
Produced in: Saint Petersburg
Installation for measuring radio technical characteristics of dielectric materials
Installation for measuring radio technical characteristics of dielectric materials
Designed for: measurements of the relative permittivity and the tangent of the dielectric loss angle of materials at a frequency of 9 GHz in accordance with GOST R 8.623-2015 "GSI.
VNIIFTRI
Mendeleevo
Produced in: Mendeleevo, Moscow region
Electromagnetic radiation level meter P3-100
Electromagnetic radiation level meter P3-100
Broadband electromagnetic radiation meters P3-100 (hereinafter referred to as meters P3-100) are designed for measurements energy flux densities (PPE) in the frequency range from 300 MHz to 40 GHz; electric field strength (NEP) from 9 kHz to 300 MHz; magnetic field strength (NEP) from 9 kHz to 50 MHz.
NNPO im. M.V.Frunze
Nizhny Novgorod
Produced in: Nizhny Novgorod
UPN‑AT140 NEUTRON RADIATION CALIBRATION UNIT
UPN‑AT140 NEUTRON RADIATION CALIBRATION UNIT
The field of fast and thermal neutrons in a collimated beam Fast neutron field in “open” geometry using a screening cone according to ISO 8529-2 Drum source magazine with polyethylene and concrete protection at a depth of 1 meter Software control of the movement of sources and positioning of the mobile platform An alarm and blocking systems, radiation monitoring Control from the operator panel or computer with verification automation functions
Produced in: Belarus, Minsk