TEKHNOYAKS

TEKHNOYAKS

61 products
View:
Telephone number:
Website: tehnojaks.com
Address:
Russia, Moscow, 30
Website: tehnojaks.com
Address:
Russia, Moscow, 30
  • Selected: 0
    Applying
  • Selected: 0
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
    All filters
    • 6
      Applying
    • 15
      Names
    • 1
      Manufacturer
    • 1
      Made in
    • 0
      Additional
      View:
      51 products
      Universal frequency meter Ch3-86A
      Universal frequency meter Ch3-86A
      The frequency meter is capable of operating both independently and as part of automated measuring systems with an interface such as USB, RS-232 or IEEE-488 (CPC). Technical specifications Frequency and period of sinusoidal and video pulse signals (input A) 0.005 Hz - 100 MHz Frequency of sinusoidal and video pulse signals (input to) 0.01 Hz - 100 MHz Frequency of continuous sinusoidal oscillations (input C) (0.1 - 1) GHz Frequency of continuous sinusoidal oscillations (input D) (0.6 - 17.85) GHz Pulse duration 10 ns - 10000 s The duration of the front, the decay of the pulses is 5 ns - 100 microseconds Time interval from 0 to 10000 s The frequency ratio of the two signals is up to 109 The average value of the carrier frequency of the pulse-modulated (IM) signal (input D) (0.6 - 17.85) GHz Frequency measurement resolution 2x10-10 s/Rng Phase difference of two synchronous sinusoidal signals from minus 180° to 180° Measurement error of the phase difference of two synchronous sinusoidal signals ± 0.36° (from 1 kHz to 1 MHz)±3.6° (above 1 MHz) Input signal level: •for sinusoidal signal (inputs A, B) (0.03 - 7.0) V •for video pulse signal (inputs A, B) (0.1 - 10.0) V •for a sinusoidal signal (input C) (0.03 - 1.0) V •for sinusoidal and IM signals (input D) 30 MW - 5 MW Input resistance •Inputs A, B (50±2.5) ohms; (1±0.1) MOm/100 pF •inputs C, D (50±2.5) ohms Nominal frequency value of the reference quartz oscillator 10 MHz Relative error in the frequency of the quartz oscillator, no more than ± 2x10-7 in 12 months Operating temperature range from minus 10 to 50 °C AC power supply 220 V, 50 Hz; 220 V, 400 Hz Power consumption, no more than 50 VA Overall dimensions, mm 229x136x435.5 Weight, not more than 7.5 kg
      Produced in: Moscow
      DC power supply B5-79/1
      DC power supply B5-79/1
      The source is capable of operating both independently and as part of automated measuring systems with interfaces such as RS-232 and ETHERNET Technical specifications Output voltage setting range from 0 to 60 V Output current setting range from 0.2 to 10 A Electrical output power, not less than 300 W The main error of the output voltage setting is ± 100 mV The main error of the output current setting is ± 100 mA Additional error in setting the output voltage caused by a deviation of the mains voltage from the nominal value by ± 10% ± (0.0001 · Uust + 1 mV) Additional error in setting the output voltage caused by a change in the load current from 0.9 of the maximum value to zero ± (0.0002 · Uust + 5 mV) Additional error in setting the output current caused by a deviation of the mains voltage from the nominal value by ± 10% ± (0.0002 · Iust + 2 mA) Additional error in setting the output current caused by a change in the load voltage from 0.9 of the maximum value to zero ± (0.0005 · Iust + 5 mA) Instability of the output voltage for any 10 minutes during 8 hours of continuous operation, no more than ± 50 mV Instability of the output current for any 10 minutes during 8 hours of continuous operation, no more than ± 50 mA Operating temperature range from 10 to 50 °C AC power supply 220 V, 50 Hz Power consumption, no more than 500 VA Overall dimensions, mm 240x128x313 Weight, not more than 6.0 kg
      Produced in: Moscow
      PKV-IB-7,2×3,4
      PKV-IB-7,2×3,4
      Basic properties Wide frequency range; Small VSWR values. Operating conditions Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 7.2×3.4 Type of coaxial connector (according to GOST RV 51914-2002) IB Frequency range, GHz 25.96-37.50 VSWR 1.35
      Produced in: Moscow
      Universal mobile complex for verification and repair of measuring instruments
      Universal mobile complex for verification and repair of measuring instruments
      The complex is equipped with air conditioning, heating and ventilation systems to create and maintain a set temperature level (20-25) ° C in the container body, at an outdoor temperature from minus 40 ° C to 40 ° C. Operating conditions Ambient air temperature from minus 40 to 40 ° C; Relative humidity up to 95 % at tº= 30 ° C; Atmospheric pressure from 84.0 to 106.7 kPa (from 630 to 800 mm Hg); General-purpose power supply: alternating three-phase current with a frequency of (50 ± 1) Hz with a RMS voltage value in each phase (380 ± 38) V. A set of functionally related working standards, special equipment and automation tools allows you to implement complex metrological maintenance of measuring instruments at automated (automated) and non-automated (RM) workplaces
      Produced in: Moscow
      FNCH-45
      FNCH-45
      Basic properties Low bandwidth losses; A wide barrage strip. Operating conditions Operating temperature range from minus 10 up to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 5.2×2.6 Bandwidth Fh-Fb at the level of -1 dB, GHz 37-45 The barrage band at the level of -30 dB, GHz 50-70 Bandwidth loss, 0.5-1.0 dB
      Produced in: Moscow
      VD-3.6×1.8
      VD-3.6×1.8
      A flexible waveguide is a piece of high-quality dielectric, which ends with transitions to standard waveguides with flanges. For ease of operation, the waveguide is protected by an elastic shell. Basic properties Manufacturability of the connection; Small losses and VSWR; Economy. Operating conditions Operating temperature range from 5 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 3.6×1.8 Flange type according to GOST RV 51914-2002 Frequency range, GHz 53.57-78.33 VSWR 1.25 Losses, 2.5 dB Length, mm* 500
      Produced in: Moscow
      Verification module PM-9
      Verification module PM-9
      The composition of the PM-9 calibration module: Universal voltmeter calibrator H4-12 (2 pcs.); Variable voltage calibrator H5-5A; A measure of the stress ratio H4-8; AC voltage voltmeter VK3-78A; Generator-calibrator of harmonic signals SK6-122; The meter-calibrator of the harmonic coefficient SK6-20A; AC power source B2-7 (2 pcs.); The measure of DC electrical resistance is multi-valued MS3070-2; The measure of DC electrical resistance is multi-valued MS3055; Decadal high-resistance resistance magazine M-109R; Single-digit electrical resistance measures MS3080 (0.001; 0.01; 0.1 ohms); Electrical resistance measures unambiguous MS3050M (1, 10, 100, 1000, 10000, 100000 Om); The measure of electrical resistance is unambiguous P4013; The measure of electrical resistance is unambiguous P4023; The measure of electrical resistance is unambiguous P4033; PC, printer; Basic load-bearing structures (BNC). Technical specifications Measuring ranges of electrical quantities: Constant electrical voltage DC from 1 MV to 1000 V AC alternating electric voltage in the frequency range of 10 Hz ... 1 MHz from 10 mV to 1000 V Alternating electric voltage high-frequency VRF in the frequency range of 10 Hz ... 2000 MHz from 10 mV to 100 V Harmonic coefficient in the frequency range of 10 Hz ... 200 kHz from 0.001 to 100 % Ranges of reproduction of electrical quantities: Constant electrical voltage DC from 1 nV to 1000 V AC alternating electric voltage in the frequency range of 10 Hz ... 1 MHz from 3 MV to 1000 V Alternating electric voltage high-frequency VRF in the frequency range of 1 MHz ... 2000 MHz from 3 MV to 3 V DC electric current from 1 µA to 20 A The power of alternating electric current in the frequency range from 0.1 Hz to 10 kHz from 1 µA to 20 A Electrical resistance from 0.001 ohms to 11 ohms Harmonic coefficient in the frequency range from 10 Hz to 200 kHz from 0.001 to 100 % Measurement errors of electrical quantities: Constant electrical voltage DC ± (0.0011 ... 4.0) % AC alternating electric voltage, in the frequency range 10 Hz ... 1 MHz ± (0.0055 ... 1.2) % Alternating electric voltage high-frequency VRF in the frequency range 1 MHz ... 2000 MHz ± (0.2 ... 6.0) % Harmonic coefficient in the frequency range from 10 Hz to 200 kHz ± (0.0008 ... 2.0) % Errors in the reproduction of electrical quantities: Constant electrical voltage DC ± (0.0011 ... 4.0) % AC alternating electric voltage in the frequency range 10 Hz ... 1 MHz ± (0.0055 ... 4.0) % Alternating electric voltage high-frequency VRF in the frequency range 1 MHz ... 2000 MHz ± (0.6 ... 10.0) % DC power ± (0.0033 ... 0.5) % The power of alternating electric current in the frequency range from 10 Hz to 10 kHz ± (0.055 ... 1.0) % Electrical resistance ± (0.001 ... 1.0) % Harmonic coefficient in the frequency range from 10 Hz to 200 kHz ± (0.006 ... 2.0) % General technical characteristics: The area occupied by the module is 6-12 m2 Weight, not more than 430 kg Power supply voltage from 198 to 242 V with a frequency of (50 ± 0.5) Hz Power consumption, no more than 2000 VA
      Produced in: Moscow
      FNCH-78
      FNCH-78
      Structurally, waveguide LPF 37-78 GHz are made on metal plates located in the center of the E-plane of the waveguide. These LFS can be used in conjunction with waveguide bandpass filters to increase the suppression of spurious signals and expand the upper band of the barrier. Basic properties Low bandwidth losses; A wide barrage strip. Operating conditions Operating temperature range from minus 10 up to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 3.6×1.8 Bandwidth Fh-Fb at the level of -1 dB, GHz 60-78 The barrier band at the level of -30 dB, GHz 85-120 Bandwidth loss, 0.5-1.2 dB
      Produced in: Moscow
      Universal frequency meter Ch3-92
      Universal frequency meter Ch3-92
      The frequency meter is able to work both independently and as part of automated measuring systems with interfaces such as USB or RS-232. Technical specifications Frequency and period of sinusoidal signals (inputs A, B) 0.001 Hz - 300 MHz Frequency and period of video pulse signals (inputs A, B) 0.001 Hz - 300 MHz Frequency of continuous sinusoidal oscillations (input C) (0.3 – 37.5) GHz Pulse duration 10 ns - 1000 s The duration of the front, the decay of the pulses is 5 ns - 100 microseconds Time interval from -1000 to 1000 s Frequency measurement resolution 2x10-10 s/Rng The range of setting the trigger levels (inputs A, B) from minus 2.5 to 2.5 V The error of setting the trigger levels (inputs A, B) ± 0.05 V Input signal level: • for sinusoidal signal (inputs A, B) (0.03 - 10.0) V • for video pulse signal (inputs A, B) (0.1 - 10.0) V • for sinusoidal signal (input C) 50 MW - 5 MW Input resistance • Inputs A, B (50±2.5) ohms; (1±0.1) MOm/100 pF • Input With (50±2.5) ohms Nominal frequency value of the reference quartz oscillator 10 MHz Relative error in the frequency of the quartz oscillator, no more than ± 2x10-7 in 12 months Operating temperature range from minus 10 to 40 °C AC power supply 220 V, 50 Hz Power consumption, not more than 100 VA Overall dimensions, mm 299x136x436,5 Weight, not more than 8.5 kg
      Produced in: Moscow
      Generator of test pulses G9-1A
      Generator of test pulses G9-1A
      The generator is capable of operating both autonomously and as part of automated measuring systems with interfaces such as RS-232 and ITHERNET. Technical specifications The range of setting the pulse duration at the outputs: - τ1 from 100 ns to 10 s - t2 from 101 ns to 10.1 s - t3 from 10 ns to 3600 s The range of setting the time interval between the pulse fronts at outputs t1 and t2 (∆tx) is from 0 to 3600 s The main error in setting the pulse duration at outputs t1 and t2 ± (δ0 • t1,2 + 1•10-8 c) The basic error of setting the pulse duration at the output is τ3 ± (δ0 •τ3 + 2 •10-9 s) The main error in setting the duration of the time interval (∆tx): ∆tx from 0 to 1000 s ± (δ0 •∆tx + 2•10-10 s) ∆tx from 1000 to 3600 s ± (δ0 •∆tx + 2•10-9 s) Pulse amplitude at outputs τ1 , τ2 and τ3 at a load of 50 ohms, not less than 1.2 V The nominal frequency value of the reference quartz oscillator is 10 MHz Relative error in the frequency of the quartz oscillator (δ0 ), no more than ± 2x10-7 in 24 months The pulse repetition frequency setting range at outputs τ4 and τ5 is from 0.1 Hz to 300 MHz The main error in setting the pulse repetition frequency at outputs τ4 and τ5 ± δ0 •F = τ4.5 Pulse amplitude setting range at outputs τ4 and τ5 from 0.05 to 1 V The main error in setting the pulse amplitude at outputs τ4 and τ5 ± 20% Fixed values of pulse durations at the output of τ6 1 and 5 microseconds The basic error of setting the pulse duration at the output is τ6 ± (0.2•τ6 + 3 •10-7 s) The nominal value of the pulse repetition frequency at the output is τ6 100 kHz The main error in setting the pulse repetition frequency at the output is τ6 ± δ0 •F = τ6 Fixed values of the pulse amplitude at the output of τ6 minus 10 V; minus 2.5 V; 2.5 V; 10 V The main error in setting the pulse amplitude at the output is τ6 ± 20% Operating temperature range from 5°C to 40 °C AC power supply 220 V, 50 Hz Power consumption, not more than 100 VA Overall dimensions, mm 442x160x452 Weight, not more than 10 kg
      Produced in: Moscow
      DC power supply B5-80 (81, 82)
      DC power supply B5-80 (81, 82)
      The devices are used both independently and as part of automated systems when working with control from a PC via the RS 232; RS 485 interface. Technical specifications Operating temperature range from 5 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 400 VA Overall dimensions, mm 266x105x398 Weight, not more than 8 kg
      Produced in: Moscow
      Mobile laboratory of measuring equipment PLIT-A2-4/1M
      Mobile laboratory of measuring equipment PLIT-A2-4/1M
      The complex is equipped with air conditioning, heating and ventilation systems to create and maintain a preset temperature level (20 ...25) ° C in the van body, at an outdoor temperature from minus 40 ° C to 40 ° C. PLIT-A2-4/1M is equipped with a removable diesel electric unit with a capacity of 16 kW, which ensures the functioning of all systems in autonomous mode. A set of functionally related working standards, special equipment and automation tools allows you to implement comprehensive metrological maintenance of measuring instruments at workplaces
      Produced in: Moscow