TEKHNOYAKS

TEKHNOYAKS

61 products
View:
Telephone number:
Address:
Russia, Moscow, null, 30null
Адрес:
Russia, Moscow, null, 30null
  • Selected: 0
    Applying
  • Selected: 0
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
    All filters
    • 6
      Applying
    • 16
      Names
    • 1
      Manufacturer
    • 1
      Made in
    • 0
      Additional
      View:
      51 products
      High-frequency signal generator G4-232
      High-frequency signal generator G4-232
      A remote frequency converter with coaxial output extends the frequency range up to 37.5 GHz. The included coaxial-waveguide transitions and the ability to connect a small frequency converter directly to the user's device expand the scope of the device. The generator is capable of operating both independently and as part of automated measuring systems with USB and IEEE-488 (CPC) interfaces. Technical specifications The frequency range at the output of the base unit is from 5 to 20 GHz The frequency range at the output of the frequency converter is from 5 to 37.5 GHz Frequency tuning discreteness 0.001 Hz The main error of the frequency setting is ± 3x10-7 Hz The range of setting the signal power level at the output of the base unit is from minus 110 to 13 dBm The range of setting the signal power level at the output of the frequency converter is from 0 to 13 dBm The basic error of setting the reference power level is ± (1.0 – 2.0) dB Metrological characteristics of the generator in the FM operation mode: - frequency range of the modulating signal: LF from 1 Hz to 20 kHz RF from 10 Hz to 100 kHz - frequency deviation setting range (taking into account the carrier frequency value): LF from 1 Hz to 200 kHz RF from 10 Hz to 10000 kHz - the main error of the frequency deviation setting is ± (5 – 18)% Metrological characteristics of the generator in AM operation mode: - frequency range of the modulating signal from 0.05 to 5.0 kHz - the range of setting the amplitude modulation coefficient from 1 to 50 % - the basic error of setting the amplitude modulation coefficient: internal ± (0.15 M + 0.2)% external ± (0.20 M + 0.5)% Metrological characteristics of the generator in the IM operation mode: - the duration range of modulating pulses from 100 ns to 20 s - the range of the modulating pulse repetition period from 140 ns to 30 s - the difference in the duration of the output RF pulses from the duration of the modulating pulses ± 100 ns Operating temperature range from minus 10°C to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 150 VA Overall dimensions, mm 498x136x487 Weight, not more than 20 kg
      Produced in: Moscow
      Spectrum Analyzer SK4-105
      Spectrum Analyzer SK4-105
      The spectrum analyzer is capable of working both independently and as part of automated measuring systems with USB and ETHERNET interfaces. Technical specifications Frequency range from 9 kHz to 20 GHz The basic error of frequency measurement is ± (3-10'7hG + 0.2 Hz) Viewing bands 0; 10 Hz - 20 GHz Bandwidth minus 3 dB from 1 Hz to 8 MHz Self-noise level from minus 156 to 145 dB MW/Hz The basic level measurement error is ± (1.2-1.8) dB The relative level of interference caused by intermodulation distortions of the 3rd order from minus 50 to 65 dB The relative level of interference caused by combination distortions from minus 60 to 80 dB Amplitude scales linear, quadratic, logarithmic (0.1- 20) dB/div The frequency range of the tracking generator is from 1 MHz to 8 GHz Operating temperature range from 5 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 85 VA Overall dimensions, mm 420x213x172 Weight, not more than 8 kg
      Produced in: Moscow
      UCHX2-78
      UCHX2-78
      Basic properties: Wide frequency range; Sufficiently large output power; High level of suppression of side harmonics of the input signal; Low phase noise value; Relatively simple technical solutions: - synchronization and frequency stabilization, - stabilization and adjustment of the output power level, - implementation of amplitude and frequency modulation modes; Do not require external bias diodes. Operating conditions: Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical characteristics Input/output frequency range, GHz 26,78-39,17 / 53,57-78,33 Losses (max.), dB 15 Input power level, dBm 15-21 Unevenness of output power (Rvh. = 20 dBm), dB ± 2.0 The level of parasitic harmonics of the input signal at the output (min.), dBn 20 Output VSWR (max.) 2.0 Connector type: • Input Coax. 2.4/1.0 mm (plug/socket) • Output Waveguide 3,759x1,88 mm (50-75GGo) Overall dimensions, mm 26x20x20 Weight, g 50
      Produced in: Moscow
      High-frequency signal generator G4-229
      High-frequency signal generator G4-229
      The generator is capable of operating both independently and as part of automated measuring systems with USB and IEEE-488 (CPC) interfaces. Technical specifications Frequency range (RF output) from 9 kHz to 6 GHz Frequency range (LF outputs) from 0.001 Hz to 30 MHz Frequency tuning discreteness (RF output) 1 Hz Frequency tuning discreteness (LF outputs) 0.001 Hz The main error of the frequency setting is ± 3x10-7 Hz The range of setting the output signal power level at the main RF output is from minus 120 to 13 dBm The range of setting the signal amplitude at a load of 50 ohms (LF outputs) from 0.01 to 5 V The basic error of setting the reference power level (RF output) ± (0.5 – 1.0) dB The basic error of setting the amplitude of sinusoidal signals (LF outputs) ± (3 – 15)% Instability of the signal power level for any 15-minute time interval (RF output) no more than 0.1 dB Metrological characteristics of the generator in the FM operation mode: - frequency range of the modulating signal from 1 to 100 kHz - frequency deviation setting range (taking into account the carrier frequency value) from 12.5 to 4000 kHz - the basic error of setting the frequency deviation ± (10 – 20)% Metrological characteristics of the generator in AM operation mode: - frequency range of the modulating signal from 0.05 to 5.0 kHz - the range of setting the amplitude modulation coefficient from 1 to 100 % - the basic error of setting the amplitude modulation coefficient (when operating from an internal signal source) ± (0.15 M + 0.2)% Metrological characteristics of the generator in the IM operation mode: - the duration range of modulating pulses from 100 ns to 20 s - the range of the modulating pulse repetition period from 140 ns to 30 s - the difference in the duration of the output RF pulses from the duration of the modulating pulses ± 100 ns Operating temperature range from minus 10 to 40 °C AC power supply 220 V, 50 Hz Power consumption, not more than 100 VA Overall dimensions, mm 498x136x487 Weight, not more than 15 kg
      Produced in: Moscow
      Universal calibrator H4-20A
      Universal calibrator H4-20A
      The calibrator is capable of operating both independently and as part of automated measuring systems with interfaces such as RS-232 and ETHERNET. Technical specifications Ranges of reproduction of quantities: - constant electrical voltage from 500 MV to 1000 V - alternating electric voltage in the frequency range from 40 Hz to 2.5 kHz from 1 mV to 1000 V - the power of direct electric current from 10 µA to 50 A - the power of alternating electric current in the frequency range from 40 Hz to 2.5 kHz from 100 µA to 50 A - frequency of alternating electric voltage from 40 Hz to 2.5 kHz Errors in reproducing quantities: - constant electric voltage ± (0.02 – 2.4)% - alternating electric voltage in the frequency range from 40 Hz to 2.5 kHz ± (0.03 – 2.1)% - constant electric current ± (0.03 – 0.25)% - alternating electric current in the frequency range from 40 Hz to 2.5 kHz ± (0.04 -0.25)% - frequency of alternating electric voltage ± 0.02% The value of the phase shift between voltage and current with simultaneous ignition ± 2 ° General characteristics: Operating temperature range from 5 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 1000 VA Overall dimensions, mm 455x198x463 Weight, not more than 20 kg
      Produced in: Moscow
      PKV-IB-5,2×2,6
      PKV-IB-5,2×2,6
      Basic properties Wide frequency range; Small VSWR values. Operating conditions Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 5.2×2.6 Type of coaxial connector (according to GOST RV 51914-2002) IB Frequency range, GHz 37.50-50.00 VSWR 1.45
      Produced in: Moscow
      High-frequency signal generator G4-227
      High-frequency signal generator G4-227
      The generator is capable of operating both independently and as part of automated measuring systems with USB and IEEE-488 (CPC) interfaces. Technical specifications Frequency range from 9 kHz to 6 GHz Frequency tuning discreteness of 1 Hz The main error of the frequency setting is ± 3x10-7 Hz The range of setting the output signal power level at the main output is from minus 10 to 13 dBm The basic error of setting the reference power level is ± (0.5 – 1.0) dB Instability of the output signal power level for any 15-minute time interval of no more than 0.1 dB Metrological characteristics of the generator in the FM operation mode: - frequency range of the modulating signal from 1 to 100 kHz - frequency deviation setting range (taking into account the carrier frequency value) from 12.5 to 4000 kHz - the main error of the frequency deviation setting is ± (20 – 25)% Metrological characteristics of the generator in AM operation mode: - frequency range of the modulating signal from 0.05 to 5.0 kHz - the range of setting the amplitude modulation coefficient from 1 to 100 % - the basic error of setting the amplitude modulation coefficient ± (0.25 M + 0.2)% Metrological characteristics of the generator in the IM operation mode: - the duration range of modulating pulses from 300 ns to 20 s - the range of the modulating pulse repetition period from 340 ns to 30 s - the difference in the duration of the output RF pulses from the duration of the modulating pulses ± 200 ns Operating temperature range from minus 10 to 40 °C AC power supply 220 V, 50 Hz Power consumption, not more than 100 VA Overall dimensions, mm 498x136x487 Weight, not more than 13 kg
      Produced in: Moscow
      Measuring step attenuator D1-29
      Measuring step attenuator D1-29
      The device replaces the devices for checking the attenuators D1-13A and D1-25. D1-29 is a step attenuator with a range of attenuation from 0 to 110 dB with a step of 10 dB, operating in the frequency range from 0 to 150 MHz. The device consists of a housing with damping cells and a switch with a counting device. The housing contains coaxial input and output connectors, as well as additional connectors "40 dB" and "80 dB", necessary for the verification of the device. Technical specifications Operating frequency range 0 – 150 MHz Difference attenuation setting range (after 10 dB) 0 – 110 dB Input electrical resistance to direct current 50 ± 0.1 ohms The output electrical resistance to direct current when connected to the load input is 50 ± 0.1 ohms 25 ± 0.1 ohms The main absolute error of the difference attenuation setting relative to the 0 dB mark at direct current ± (0.002 - 0.02) dB The main absolute error of the difference attenuation setting relative to the 10 dB mark in the frequency range up to 30 MHz ± (0.004 - 0.9) dB The main absolute error of the difference attenuation setting relative to the 10 dB mark in the frequency range over 30 to 150 MHz ± (0.09 - 3.0) dB The maximum permissible value of the electrical voltage (DC or AC) at the input of the attenuator 3 In the operating temperature range from 5 to 40 ° C Overall dimensions, mm 149x95x149 Weight, not more than 3 kg
      Produced in: Moscow
      DC power supply B5-83
      DC power supply B5-83
      The B5-83 DC power supply is designed to provide constant voltage and current to devices and equipment during the development, production, operation and repair of electronic devices. - Allows harsh operating conditions - Wide range of currents and voltages at a maximum power of 200 watts Technical specifications Output voltage setting range from 3 to 300 V Output current setting range from 0.05 to 2 A Electrical output power, not more than 200 watts The main error of the output voltage setting is ± 2 V The main error of setting the output current is ± 0.02 A Additional error in setting the output voltage caused by a deviation of the mains voltage from the nominal value by ± 10% ± (0.0001 · Uust + 3 mV) Additional error in setting the output voltage caused by a change in the load current from 0.9 of the maximum value to zero ± (0.0002 · Uust + 10 mV) Additional error in setting the output current caused by a deviation of the mains voltage from the nominal value by ± 10% ± (0.0002 · Iust + 1 mA) Additional error in setting the output current caused by a change in the load voltage from 0.9 of the maximum value to zero ± (0.0005 · Iust + 2 mA) The change in the output voltage in the voltage stabilization mode with a deviation of the ambient temperature in the operating temperature range by ± 10 ° C, not more than ± 250 mV Change of the output current in the current stabilization mode with a deviation of the ambient temperature in the operating temperature range by ± 10 ° C, not more than ± 10 mA Operating temperature range from minus 10 to 50 °C AC power supply 220 V, 50 Hz Power consumption, no more than 350 VA Overall dimensions, mm 240x128x313 Weight, not more than 5.5 kg
      Produced in: Moscow
      VD-7.2×3.4
      VD-7.2×3.4
      A flexible waveguide is a piece of high-quality dielectric, which ends with transitions to standard waveguides with flanges. For ease of operation, the waveguide is protected by an elastic shell. Basic properties Manufacturability of the connection; Small losses and VSWR; Economy. Operating conditions Operating temperature range from 5 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 7.2×3.4 Flange type according to GOST RV 51914-2002 Frequency range, GHz 25.95-37.50 VSWR 1.25 Losses, dB 2.0 Length, mm* 500
      Produced in: Moscow
      UCHX2-37
      UCHX2-37
      Basic properties: Wide frequency range; Sufficiently large output power; High level of suppression of side harmonics of the input signal; Low value of phase noise; Relatively simple technical solutions: - synchronization and frequency stabilization, - stabilization and adjustment of the output power level, - implementation of amplitude and frequency modulation modes; Do not require external bias diodes. Operating conditions: Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical characteristics Input/output frequency range, GHz 12,93-18,75 / 25,86-37,5 Losses (max.), dB 13 Input power level, dBm 15-21 Unevenness of output power (Rvh. = 20 dBm), dB ± 1.5 The level of parasitic harmonics of the input signal at the output (min.), dBn 20 Output VSWR (max.) 2.0 Connector type: • Input Coax. 3.5/1.5 mm (socket) • Output Waveguide 7.2x3.4 mm Overall dimensions, mm 29x24x24 Weight, g 60
      Produced in: Moscow
      PKV-IP-7,2×3,4
      PKV-IP-7,2×3,4
      Basic properties Wide frequency range; Small VSWR values. Operating conditions Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 7.2×3.4 Type of coaxial connector (according to GOST RV 51914-2002) IP Frequency range, GHz 25.96-37.50 VSWR 1.35
      Produced in: Moscow