TEKHNOYAKS

TEKHNOYAKS

61 products
View:
Telephone number:
Address:
Russia, Moscow, null, 30null
Адрес:
Russia, Moscow, null, 30null
  • Selected: 0
    Applying
  • Selected: 0
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
    All filters
    • 6
      Applying
    • 16
      Names
    • 1
      Manufacturer
    • 1
      Made in
    • 0
      Additional
      View:
      51 products
      Mobile laboratory of measuring equipment PLIT-A2-4/1M
      Mobile laboratory of measuring equipment PLIT-A2-4/1M
      The complex is equipped with air conditioning, heating and ventilation systems to create and maintain a preset temperature level (20 ...25) ° C in the van body, at an outdoor temperature from minus 40 ° C to 40 ° C. PLIT-A2-4/1M is equipped with a removable diesel electric unit with a capacity of 16 kW, which ensures the functioning of all systems in autonomous mode. A set of functionally related working standards, special equipment and automation tools allows you to implement comprehensive metrological maintenance of measuring instruments at workplaces
      Produced in: Moscow
      High-frequency signal generator G4-230
      High-frequency signal generator G4-230
      The generator is capable of operating both autonomously and as part of automated measuring systems with USB and IEEE-488 (CPC) interfaces. Technical specifications Frequency range from 5 to 17.85 GHz Frequency tuning discreteness 0.001 Hz The main error of the frequency setting is ± 3x10-7 Hz The range of setting the output signal power level at the main output is from minus 110 to 13 dBm The basic error of setting the reference power level is ± 1.0 dB Instability of the output signal power level for any 15-minute time interval of no more than 0.1 dB Metrological characteristics of the generator in the FM operation mode: - frequency range of the modulating signal: low frequency from 1 Hz to 20 kHz RFM from 10 to 100 kHz - frequency deviation setting range (taking into account the carrier frequency value): low frequency from 1 Hz to 100 kHz RFM from 50 to 10000 kHz - the main error of the frequency deviation setting is ± (3 – 18)% Metrological characteristics of the generator in AM operation mode: - frequency range of the modulating signal from 0.05 to 5.0 kHz - the range of setting the amplitude modulation coefficient from 1 to 50 % - the main error in setting the amplitude modulation coefficient: Internal ± (0.15M + 0.2)% External ± (0.20M + 0.5)% Metrological characteristics of the generator in the IM operation mode: - the duration range of modulating pulses from 100 ns to 20 s - the range of the modulating pulse repetition period from 140 ns to 30 s - the difference in the duration of the output RF pulses from the duration of the modulating pulses ± 100 ns Operating temperature range from minus 10 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 150 VA Overall dimensions, mm 498x136x487 Weight, not more than 15 kg
      Produced in: Moscow
      Universal frequency meter Ch3-89
      Universal frequency meter Ch3-89
      The frequency meter is able to work both independently and as part of automated measuring systems with interfaces such as USB or RS-232. Technical specifications Frequency and period of sinusoidal signals (inputs A, B) 0.001 Hz - 150 MHz Frequency of video pulse signals (inputs A, B) 0.001 Hz - 100 MHz Frequency of continuous sinusoidal oscillations (input C) (0.1 - 1) GHz Frequency of continuous sinusoidal oscillations (input D) (1 - 37.5) GHz Carrier frequency of a continuous signal with frequency modulation (FM) (input D) Fh = (1 - 18) GHz, Fm = 100 Hz-100 kHz; frequency deviation from 10 kHz to 10 MHz Carrier frequency of a continuous signal with amplitude modulation (AM) (input D) Fh = (1 - 18) GHz, Fm = 100 Hz - 100 kHz; AM factor up to 100% Carrier frequency of a continuous radio pulse sequence (IM) signal (input D) Fn = (1-37.5) GHz, from 0.15 microseconds to 1ms, Fsl from 100 Hz to 3 MHz, from 2 to 103 Pulse duration 10 ns – 0.1 s Time interval from -10 to 10 s The duration of the front, the decay of the pulses is 5 ns - 100 microseconds Phase difference of two synchronous sinusoidal signals from minus 360° to 360° The measurement error of the phase difference of two synchronous sinusoidal signals is ± 0.36° (from 1 kHz to 1 MHz) ± 3.6° (above 1 MHz) Input signal level: •for sinusoidal signal (inputs A, B) (0.03 - 7.0) V •for video pulse signal (inputs A, B) (0.1 - 10.0) V •for a sinusoidal signal (input C) (0.03 - 1.0) V •for sinusoidal and IM signals (input D) 10 MW (from 1 to 8 GHz); 40 MW (sv. 8 to 18 GHz); 50 MW (sv. 18 to 37.5 GHz). The nominal frequency value of the reference quartz oscillator is 10 MHz Relative error in the frequency of the quartz oscillator, no more than ± 2x10-7 in 12 months Operating temperature range from 5 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 100 VhA Overall dimensions, mm 496x174x459 Weight, not more than 16 kg
      Produced in: Moscow