NPF "META-KHROM"

NPF "META-KHROM"

73 products
View:
Telephone number:
Address:
Russia, Yoshkar-Ola, null, 100null
Адрес:
Russia, Yoshkar-Ola, null, 100null
  • Selected: 0
    Applying
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • 7
    Applying
  • 30
    Names
    Loading...
  • 1
    Manufacturer
  • 2
    Made in
  • 13
    Additional
View:
71 products
CRYSTAL-2000 CHROMATOGRAPH
CRYSTAL-2000 CHROMATOGRAPH
Technical characteristics: DETECTOR - TYPE OF CHROMATOGRAPH - DETECTION LIMIT, G/S (G/ML) -STANDARD DEVIATION, % - LEVEL OF FLUCTUATIONAL NOISES, A (V) -DRIFT, А/H (V/H) FID Crystall-2000 5×10⁻¹² 2 2×10⁻¹⁴ 4×10 ⁻¹³ TCD Crystall-2000 (5×10⁻⁹) 2 (2×10⁻⁷) (2×10⁻⁵) ADC Crystall-2000 5×10⁻¹⁴ 4 1×10⁻¹² 8×10⁻¹¹ FPD-Р Crystall-2000 2×10⁻¹² 6 2×10⁻¹¹ 4×10⁻¹⁰ FPD-S Crystall-2000 2×10⁻¹¹ 10 2×10⁻¹¹ 4×10⁻¹⁰
Produced in: Yoshkar-Ola, Mari El
AIR GENERATOR
AIR GENERATOR
In addition to air compressors of the type "KOV-4", a pure air generator of the type "GCHV" is produced. Our equipment undergoes thorough quality control, which is confirmed by certificates of conformity. The device is used to provide clean air supply to gas analyzers and flame ionization detectors of chromatographs. Technical specifications: Air capacity reduced to normal conditions, l/min, not less than 2.0 Outlet air pressure, 2.5 atm Outlet pressure stability, no more than 0.05 atm Output concentration of hydrocarbons, ppm, not more than 0.1 Concentration of water vapor at 200C and 100kPa, ppm, no more than 10 The value of the power consumption, not more than 200 VA Dimensions (width×depth×height), mm 210×440×360 Weight, not more than, kg 11
Produced in: Yoshkar-Ola, Mari El
LABORATORY INSTALLATION FOR MODELING THE PROCESS OF THERMAL CONTACT CRACKING. MKUB.413224.029
LABORATORY INSTALLATION FOR MODELING THE PROCESS OF THERMAL CONTACT CRACKING. MKUB.413224.029
Laboratory installation for modeling the process of thermal contact cracking (TCC) of heavy oil residues (TNO) (heavy oil fuel oil, tar and semi-tar, asphalt of the process of de-asphalting of high-viscosity oils, cracking residue or pitch, heavy gas oil, natural bitumen, etc.) with a movable solid coolant. technical specifications Operating pressure range, MPa 0÷4 Reactor operating temperature range, 0C 50÷800 Reactor inner diameter, mm, 31 Reactor length, mm, 875 Number of thermostatically controlled independent zones 4 Length of each independent isothermal zone of the furnace, mm 200 The length of the full isothermal zone of the furnace, mm 800 Thermocouple Pocket Availability The type of furnace is Casement The power consumed by each independent thermostatically controlled zone of the furnace, W 720 Power consumed by all four zones of the furnace, W 2880 The discreteness of the temperature setting, 0C 1 The flow range of the liquid pump, ml/min 0.1-10 The maximum pressure of the high-pressure liquid pump, not less than 20 MPa Flow range N2, l/min 0÷20 Pressure in the low pressure lines N2 and air, MPa ≤0.6 Operating temperature range of the evaporator-mixer of raw materials, sup>0C 50÷500 Actuation pressure of mechanical safety valves, MPa 3 Maximum pressure in the raw material container, 0.1 MPa Supply voltage 230-240V 60Hz The power consumption of the installation is not more than 3.5 kW The discreteness of the temperatures and flow rates displayed on the displays is 0.1 Installation weight without cabinet, kg 100 Overall dimensions of the installation, mm 1900x865x550 Overall dimensions of the cabinet, mm 2000x880x800 The technical characteristics of the purchased units used in the installation are given in the technical documentation for these units supplied with the installation The length of the supply pipelines, m 10 The coolant of the refrigerator "tosol"
Produced in: Yoshkar-Ola, Mari El
TRANSFORMER OIL INPUT DEVICE
TRANSFORMER OIL INPUT DEVICE
When determining the total gas content (air) and humidity of transformer oil, direct injection of transformer oil into the evaporator of the chromatograph is used. The sample volume is up to 25 µl, the evaporator temperature is 250-350 °C. The main problem with such an input is the protection of the chromatographic column from transformer oil. For this purpose, a special evaporator is used with the possibility of oil accumulation at the bottom of the evaporator and its subsequent discharge, and a replaceable pre-column that protects the column from oil residues that have passed the evaporator. technical specifications The volume of the evaporator is 10 ml. The number of replaceable pre—columns in the device kit is 5. The temperature of the evaporator is from 250 to 350 °C. The possibility of draining the transformer oil accumulated in the evaporator.
Produced in: Yoshkar-Ola, Mari El
WATER PURIFICATION DEVICES: SPECTRUM DEIONIZER
WATER PURIFICATION DEVICES: SPECTRUM DEIONIZER
The Spectrum deionizer makes it possible to obtain high–purity deionized water with a specific electrical conductivity of 0.06 - 0.1 mcm/cm and does not require connection to a municipal water supply line. Technical specifications The volume of water poured into the tank is 1.6 liters The specific electrical conductivity of the resulting water is 0.06 – 0.1 mcm/cm Water capacity of at least 6 liters/hour Filter life 700 liters
Produced in: Yoshkar-Ola, Mari El
PYROLYZER
PYROLYZER
The pyrolyzer is designed to simulate the pyrolysis process and synthesis gas production technical specifications Reactor operating temperature range, 0C 20÷1100 Reactor inner diameter, mm 22 Reactor length, mm 1350 Thermocouple pocket availability Length of the isothermal zone, mm 700 The type of furnace is Casement Number of thermostatically controlled independent zones 1 The discreteness of the temperature setting, 0C 1 The flow range of the liquid pump, ml/min 0.0048÷36 Supply voltage 220V 50Hz Power consumption not more than 3.3 kW The discreteness of the temperatures and flow rates displayed on the displays is 0.1 Installation weight without cabinet, kg 100 Overall dimensions, mm 1400 x 400 x 1250 Weight, kg 60
Produced in: Yoshkar-Ola, Mari El
GENERATOR OF STANDARD CHROMATOGRAMS (GSH-3)
GENERATOR OF STANDARD CHROMATOGRAMS (GSH-3)
The GSH-3 hardware and software complex is designed for verification of analog and digital measuring channels of the chromatograph and analog-to-digital converters (ADCs) intended for automation of old chromatographs. The device can be used in various sectors of the national economy, in factory and research laboratories. technical specifications The resolution and sampling rate of 1 DAC is 20 bits 10 Hz. The resolution and sampling rate of 2 DACs is 16 bits 20 Hz. The amount of ROM memory is 512 KB. The voltage output range (1 output) is from 0 to 5V. The current output signal range is from 1×10-14 to 1×10-7 A (2 outputs in the range of positive and negative voltages). The relative deviation of the average steady—state value of the current or voltage of the output channel from the set value is not more than 2%. The linearity error ±1 LSB (the least significant bit) is ± 4×10-7 V. Power consumption (without a personal computer), no more than — 10 VA. Overall dimensions (width × depth × height), not more than — 230×220 × 75 mm. Weight, not more than 1.4 kg.
Produced in: Yoshkar-Ola, Mari El
AUTOMATIC DIGITAL MULTI-CHANNEL PRESSURE MAINTENANCE SYSTEM IN THE VACUUM CHAMBER
AUTOMATIC DIGITAL MULTI-CHANNEL PRESSURE MAINTENANCE SYSTEM IN THE VACUUM CHAMBER
The system includes a digital ionization-thermocouple vacuum meter with a continuous pressure measurement range, automatic degassing of sensors and a digital gas flow meter containing two or more built-in precision gas flow regulators, with thermometric gas flow meters, which allows the device to operate in the mode of autonomous intake of specified gas flow rates, regardless of the inlet pressure. The letters in the diagram show: А — electronic unit of vacuum gauge B — 220V power wire С — thermocouple lamp D — ionization lamp E — the electronic control unit of the leak valve G — signal cables H — cable for data exchange with IBM J — IBM L — cable for data exchange between the units M — cable for connecting additional devices to the network N,O — working gases inlet P,R — output of the working gases.
Produced in: Yoshkar-Ola, Mari El
THERMAL DESORBER TDS-2
THERMAL DESORBER TDS-2
TDS-2 is a syringe (see Fig. 1), which is installed on the evaporator of the chromatograph. The device is equipped with a crane that cuts off the carrier gas line when removing the rod with the sorption tube from the thermal desorber. When the tap is open, the stem is lowered to the lower position and the sorption tube is inserted into the evaporator brought to the desired temperature. In the conditions of the upper position of the rod, it is also possible to displace air by purging the sorption tube with a carrier gas. Technical characteristics of TDS-2 The heating time to the desorption temperature is no more than 1 sec. The cooling time when moving to a cold zone is no more than 10 seconds. Outer diameter 5-0.1 mm Dimensions of the sorbent chamber: diameter 3.4+0.3 mm length 52 mm (470 µl) Volume (for solid samples) 90 µl Operating temperature ranges* from 50° to 400 °C Overall dimensions (height with the rod fully extended) 320 mm. Weight 0.325 kg.
Produced in: Yoshkar-Ola, Mari El
COOLING LPG SV
COOLING LPG SV
Device for dosing of liquefied gases is made for insertion of liquids and liquefied gases under the pressure of 7 MPa into the chromatograph. Injection of liquefied gas without de-gassing is provided by cooling of valve, and it greatly reduces inaccuracy of the analysis results. Cooling temperature is set by temperature regulator. Visual control of absence of de-gassing and flow control of the analyzed fluid is provided. Dose volume is form 0.2 to 2 mcl. Valve of VICI production or dispenser valve of our own production is used directly as a sample-valve.
Produced in: Yoshkar-Ola, Mari El
CRYOSTATING DEVICES
CRYOSTATING DEVICES
The separation of some substances (the classic case is the separation of oxygen and argon) requires negative temperatures of the thermostat of chromatographic columns. technical specifications The lower temperature limit of the thermostat of columns with a cooling device based on an air conditioner is minus 5 °C. The error in maintaining the temperature of the thermostat of columns with a cooling device based on an air conditioner is + 0.05 °C. The power consumption of the cooling device based on an air conditioner, no more than — 640 VA. Overall dimensions of the cooling device based on the air conditioner, (width × depth × height), no more than — 620×480× 410 mm. The weight of the cooling device based on the air conditioner, no more than 32 kg. The lower limit of the temperature of the thermostat of columns with a liquid nitrogen cryoclap is minus 100 °C. The error of maintaining the temperature of the thermostat of columns with a liquid nitrogen cryoclave (in the temperature range less than 25 °C) + 0.1 °C. The power consumption of a cooling device with a liquid nitrogen cryoclave, no more than — 10 VA. Consumption of liquid nitrogen, not more than 0.1 l/h.
Produced in: Yoshkar-Ola, Mari El