THE DEVICE FOR ACHIEVING BALANCE
THE DEVICE FOR ACHIEVING BALANCE
When analyzing gases dissolved in transformer oil using the ARP method (equilibrium vapor analysis), mixing of the contents of the syringe with oil is used to accelerate the extraction of gases (to achieve an equilibrium distribution of gases dissolved in oil between the liquid and gas phases). For this purpose, as well as automation of the mixing process, a special autonomous device for achieving equilibrium is produced. technical specifications The rotation speed of the syringe drum is 30 rpm./min. The rotation time (determined by the internal timer, after pressing the "Start" button) is 10 minutes. The number of syringes placed is 4. The volume of syringes is 20 or 50 ml. Power consumption, no more than — 14 VA. Overall dimensions, no more than 210×280×270 mm. Weight, not more than — 5 kg.
Produced in: Yoshkar-Ola, Mari El
WATER PURIFICATION DEVICES: AQUARIUS DEVICE
WATER PURIFICATION DEVICES: AQUARIUS DEVICE
Water purification in the device is carried out by passing it through a composition of deionization resins and sorbents. Resins and sorbents are located in filter elements placed in a replaceable cassette. The distilled water to be cleaned is poured into the feed tank, the filler neck of which is placed on the upper plane of the device and hermetically sealed with a screw cap. Technical specifications: The specific conductivity of the resulting water, not more than, mkSxcm 0.20 Capacity, at least, l/h 6 Operating time of the replaceable cassette (total volume of purified water), not less than 700 liters Volume of refilled distilled water, l. 1 Power consumption, not more than, VA 20 Overall dimensions (width×depth×height), mm 180×450×380
Produced in: Yoshkar-Ola, Mari El
WATER PURIFICATION DEVICES: WATER TREATMENT SYSTEM "SPECTRUM OSMOSIS"
WATER PURIFICATION DEVICES: WATER TREATMENT SYSTEM "SPECTRUM OSMOSIS"
The water treatment system (hereinafter referred to as the system) is used for the preparation of water used in hydrogen generators, for the preparation of solutions, chromatographic samples, capillary electrophoresis, high-performance liquid chromatography (HPLC), etc. analyzers requiring the use of high purity water. The system is connected directly to the municipal water supply line and allows obtaining high–purity deionized water with a specific electrical conductivity of 0.06 - 0.1 mcm/cm. The device uses multi-stage water purification. Technical specifications System output capacity, l/h not less than 6 Specific electrical conductivity of water, mcm/cm not more than 0.06 – 0.1 Power supply - single-phase AC 220V, 50/60 Hz Maximum power consumption, kW 0.1 Dimensions (W x D x H), mm 200 x 560 x 440 Weight, not more than 20 kg
Produced in: Yoshkar-Ola, Mari El
GEYSER-2A DEVICE
GEYSER-2A DEVICE
The Geyser –2A measuring and computing complex is designed to determine the dynamic characteristics and energy efficiency (caloric content) of various substances, including special products (gunpowder, explosives). The device also allows you to determine the chemical resistance of substances by the delay of the ignition time. The analysis is carried out in a given volume in the isothermal mode or in the temperature programming mode. technical specifications Operating temperature range in the reactor, from +50 to +600 ° C. The programming speed of the thermostat temperature in the operating temperature range, no more than 10 ° C. The limit of the permissible absolute error of setting the temperature of temperature control, no more than ± 2 ° C. Instability of maintaining the set temperature in the thermostat for 10 minutes, no more than ± 0.1 ° C. Sampling rate of the optical recording system, at least 25kHz The range of measurement of the ignition delay time in the isothermal mode, from 0 to 600 seconds. The measurement range of dynamic characteristics in the temperature programming mode, from 0 to 3600 sec. The continuous operation time of the device is at least 24 hours. The time for the device to enter the mode from the moment it is turned on, no more than 0.2 hours. The device is powered by AC 220V,+10/-15%,(50±1) Hz. The power consumption of the device, no more than 200 watts. The weight of the device without packaging, no more than 7 kg. Overall dimensions (width × depth × height), no more than 330×265×170 mm.
Produced in: Yoshkar-Ola, Mari El
GAS FLOW SHAPER
GAS FLOW SHAPER
The gas flow shaper (FGP) is designed to automate the old fleet of chromatographs of the LHM type, model-3700, "Color" series, etc. in terms of setting and regulating the flow and pressure of both the carrier gas and auxiliary gases. The FGP has a flexible structure and provides regulation of gas flows from two to four independent gas flow channels and up to three pressure channels. The gas pressure at the inlet is (0.4 ± 0.04) MPa. The operating flow ranges of the carrier gas are from 3 to 250 ml/min with a discreteness of 1 ml/min. The ability to specify the type of gas (nitrogen, helium, hydrogen, argon, air). The ranges of hydrogen consumption are from 3 to 250 ml/min with a discreteness of 1 ml/min. The air flow ranges from 10 to 750 ml/min with a discreteness of 1 ml/min. Pressure ranges — from 0.001 to 0.40 MPa with a discreteness of 0.0001 MPa. Deviation of the carrier gas flow rate from the average value of ± 1.5% in the flow range from 50 to 100 ml/min and ± 0.5 ml/min in the flow range from 3 to 50 ml/min. The relative deviation of the average steady-state gas flow rate from the set value in the range: from 3 to 100 ml/min. ± 2.5%, but not less than 0.5 ml/min.; from 100 to 200 ml/min. ± 5%; from 200 to 800 ml/min. ± 10%. Electric power supply from a single—phase AC network with voltage from 187 to 242 V, frequency (50 ± 1) Hz, operating mode - continuous. Power consumption, no more than — 30 VA. Overall dimensions of the FGP (width × depth × height), no more than 160 × 370× 210 mm. Weight, not more than — 8 kg.
Produced in: Yoshkar-Ola, Mari El
HIGH PRESSURE GAS FILTER UNIT
HIGH PRESSURE GAS FILTER UNIT
A block of gas filters for lines with a pressure of up to 15 MPa. The volume, length, connection dimensions, type of connections with supply pipelines are specified when ordering.
Produced in: Yoshkar-Ola, Mari El
AUTOCLAVE LABORATORY SYNTHESIS REACTOR RS 10L. MKUB.307141.033
AUTOCLAVE LABORATORY SYNTHESIS REACTOR RS 10L. MKUB.307141.033
The autoclave is designed to simulate various chemical processes occurring at elevated temperatures and pressures. Ambient temperature from +10 to +35C; The relative humidity of the air is not more than 80% at a temperature of 25C;. Atmospheric pressure from 84 to 107 kPa (from 630 to 800 mmHg); The power supply is a single–phase AC network with a voltage of 220V ± 10% with a frequency of 50 Hz. The average service life of the autoclave is 5 years. TECHNICAL CHARACTERISTICS OF THE HYDROTREATING AND HYDROGENATION UNIT Operating pressure range, MPa 0.1-2 Reactor operating temperature range, 0C 30÷200 Autoclave flask volume, l 10 The speed control range of the agitator, rpm 20÷120 The diameter of the drain bottom valve, mm 20 Flask and lid connection flanged Power supply, single-phase network 230-240V 50-60Hz Power consumption not more than, kW 1 Overall dimensions, mm 555x1880x705 Continuous operation mode
Produced in: Yoshkar-Ola, Mari El
METANATOR
METANATOR
To analyze small concentrations of carbon monoxide (CO) and carbon dioxide (CO2), instead of the usual catarometer for these gases, a more sensitive PID is used, while carbon oxides are converted into methane (CH4) using reaction chromatography. The device implementing the conversion reaction is called a methanator, i.e. a device with a special catalyst that converts CO, CO2 into methane in a hydrogen current, while the latter is either a carrier gas itself, or is blown together with the carrier gas into the methanator through a tee. The methanator provides a highly efficient conversion reaction, while the detection limit of carbon oxides reaches 0.1 ppm. technical specifications Metanation temperature — 330 °C The coefficient of metanation is not less than 95 % The effective volume of the methanator is 1 ml.
Produced in: Yoshkar-Ola, Mari El
TRANSFORMER OIL INPUT DEVICE
TRANSFORMER OIL INPUT DEVICE
When determining the total gas content (air) and humidity of transformer oil, direct injection of transformer oil into the evaporator of the chromatograph is used. The sample volume is up to 25 µl, the evaporator temperature is 250-350 °C. The main problem with such an input is the protection of the chromatographic column from transformer oil. For this purpose, a special evaporator is used with the possibility of oil accumulation at the bottom of the evaporator and its subsequent discharge, and a replaceable pre-column that protects the column from oil residues that have passed the evaporator. technical specifications The volume of the evaporator is 10 ml. The number of replaceable pre—columns in the device kit is 5. The temperature of the evaporator is from 250 to 350 °C. The possibility of draining the transformer oil accumulated in the evaporator.
Produced in: Yoshkar-Ola, Mari El
CRYOEXTRACTOR EVC-2
CRYOEXTRACTOR EVC-2
The device is designed to extract target organic substances from liquid and solid samples. Implements the latest method of sample preparation in chemical analysis - extraction freezing with centrifugation of EVCB (Patents of the Russian Federation RU2303476/2007, RU2564999/2015, Patent of the Kyrgyz Republic KG388/2020, International Application PCT/RU2015/000615). Scope of application - hydrochemistry, chemical and toxicological analysis, biochemistry, food research, etc. technical specifications The temperature range of extraction freezing with centrifugation is from -(minus) 28 to +25 °C. Rotor speed with the possibility of programming the mode 100-8000 rpm Separation factor up to 6600 g Cryoextractor power supply from AC 220 V, 50 Hz Power consumption, not more than 0.3 kW The mass of the cryoextractor is not more than 50 kg Overall dimensions (HxWxD), mmxmmxmm no more than 900x600x600 Number of simultaneously extracted samples (individually on request)
Produced in: Yoshkar-Ola, Mari El
Electronic Gripper (E3D)
Electronic Gripper (E3D)
Selective detector for organochlorine compounds and other halogens. It is also sensitive to compounds containing oxygen, phosphorus or aromatic rings, but to a lesser extent. Paraffins and simple hydrocarbons almost do not capture electrons and are not registered. The selectivity to hydrocarbons is 108. It is available in two versions — conventional EDD and micro-EDD, mainly for capillary columns (the second version is characterized by increased sensitivity). The level of fluctuation noise is up to 300 MV, the maximum signal is up to 5 V, the design of the ECD allows the use of argon, helium, and hydrogen as a carrier gas, in addition to nitrogen. Technical characteristic: 4.0*10-15 g/s for lindane
Produced in: Yoshkar-Ola, Mari El
Pulsating Discharge Detector(PRD)
Pulsating Discharge Detector(PRD)
It operates in the mode of a helium ionization detector (GID) and is considered the most sensitive device for determining permanent gases. In addition, it is able to work in the EDD mode. Technical characteristic: 2.0*10`13 g/s by. methane or hydrogen
Produced in: Yoshkar-Ola, Mari El