Capillary electrophoresis systems "KAPEL®-105M"
Capillary electrophoresis systems "KAPEL®-105M"
Technical specifications: The range of working detection wavelengths, nm from 190 to 380 Limits of permissible absolute error of setting the working wavelength, nm ± 5 The range of variation of the operating voltage on the capillary, kV from 1 to 25 The detection limit of benzoic acid (with positive polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, mcg/ cm3, not more than 0.8 The limit of detection of chloride ions (with a negative polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, micrograms / cm3, not more than 0.5 The limit of the permissible relative mean square deviation (SKO) of the output signal over the peak area, %5 The limit of the permissible relative mean square deviation (SKO) of the output signal for 8 hours of operation, % 6.5 Operating mode setting time, min, no more than 30 Power supply of systems from the AC network with voltage, V; frequency, Hz. 220 ±22 50 ±1 Power consumption consumed by the system, In ×A, no more: 220 Overall dimensions (LXC), mm, no more 420x570x360 Weight, kg, not more than 25
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury content indicator "SR-1"
Mercury content indicator "SR-1"
Technical specifications: The minimum limit of operation is 3×10-4 mg/m3 (the average daily MPC of a residential premises in accordance with GN 2.1.6.1338-03 of May 21, 2003) The range of set thresholds is from 3×10-4 mg/m3 to 1×10-3 mg/m3 Measurement time, no more than 15 s Output signals ON, READY, DANGEROUS, FAULTY Electrical parameters of the output signal 0-24 V, 0.5 A Operating mode Monitoring Average full service life of 5 years Frequency of maintenance 1 time in 3 months RS-232 digital output Power supply 190-240 V, 50 Hz Power consumption, no more than 30 watts Overall dimensions, no more than 280x420x600 mm Weight, not more than 18 kg
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Liquid analyzer "FLUORAT®-02-5M"
Liquid analyzer "FLUORAT®-02-5M"
Technical specifications: Limit of detection of the control substance (phenol) in water, mg/dm3, no more 0,005 Measurement range of the mass concentration of the control substance (phenol) in water, mg/dm3 from 0.01 to 25 Measurement range of the directional transmission coefficient, % from 5 to 100 Limits of permissible absolute error of measurements of the directional transmission coefficient, % ± 2 Warm-up time, min, no more than 30 Continuous operation time, h, at least 8 Overall dimensions, mm, no more than 305x320x110 Weight, kg, no more than 6.5 AC power supply: - AC power supply voltage, V - frequency, Hz (220 ±22) (50 ±1) Power consumption, In × A, no more than 36 Time to failure, h, not less than 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mass spectrometer for the analysis of solid-phase samples "Lumas GAS"
Mass spectrometer for the analysis of solid-phase samples "Lumas GAS"
1 supp.
from 218.11 ₽
Technical specifications: Ionization method Glow discharge plasma Discharge gas Air Time-of-flight Mass Analyzer with mesh-free ion mirror Resolution 4000 The number of simultaneously defined components is not limited Mass range 1-1000 m/z Detection limits 10-100 ppt Analysis time 1-3 min Vacuum system 1 Booster pump and 2 TMN (240 l/sec) Overall dimensions 1450×780×1550 mm
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Chromatographic columns for HPLC
Chromatographic columns for HPLC
Variants of execution: - silica gel with grafted octadecyl groups (C18, RP, ODS) - for the variant of reversed-phase HPLC (OF HPLC); - unmodified silica gel (SIL) – for normal-phase HPLC (NF HPLC).
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
The FLUORAT®-411 alarm is heated, with a built-in sample preparation system
The FLUORAT®-411 alarm is heated, with a built-in sample preparation system
Technical specifications: The power consumption of the alarm is not more than 150 watts The output electrical signal goes directly from the cable entry (B6), according to the standard scheme (4-20ma and (or) RS 485) Sample temperature is not more than 200 degrees C Sample pressure is not more than 1.5 Atm The pressure of the spent sample is not more than 0.5 Atm Cooling water temperature 5-30 Deg C Dimensions of the alarm (mm) 1200*600*400 The boundaries of the spectral range of optical radiation used for analysis, nm 240 - 380 Analysis time, from 1 Power supply - alternating voltage (220 ± 10%) V, (50± 2.5) Hz operating mode settings, min no more than 30 Display range , mg/l 0.01-30 The limit of the basic error for the trigger threshold (%) 20 The set threshold for triggering the alarm 0.1 – 30.9 in increments of 0.1 mg/l the probability of trouble-free operation during 5000 hours is not less than 0.95 average recovery time, no more than 2 hours average service life, at least 5 years
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury monitor type RA-915AM for air analysis
Mercury monitor type RA-915AM for air analysis
Technical specifications: Ambient temperature, °C from +10 to +35 Relative humidity (at +25 °C), % no more than 98 Atmospheric pressure, kPa from 84 to 106.7 Power supply 220  22 V, 50  1 Hz Power consumption, VA no more than 150 Overall dimensions (LWC), mm Monitor Multiplexer 665x482x222 665x482x222 Weight, kg Monitor Multiplexer (2-16 channels) 25 15 - 25 Average time to failure, h 12000 Average service life, 5 years
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Monochromators "LM-3" and "LM-4"
Monochromators "LM-3" and "LM-4"
Technical specifications: LM-3 operating range 220-650 nm LM-4 operating range 220-900 nm Diffraction grating (replica) 1200 strokes per millimeter Radius of curvature DR 125 mm The area of maximum energy concentration is 300-400 nm Inverse linear dispersion in the specified spectral range of 6.7 nm/mm Relative opening 1:3.3 The slits are fiber optical fibers with a diameter of 200 microns, stacked in 1 row. The height of the slots is 5 mm The resolution of the monochromator with the specified slits in the ranges of 220-650 nm is not worse than 1.5 nm The resolution of the monochromator with the specified slits in the range of 650-900 nm is not worse than 2.5 nm The accuracy of the wavelength setting is not worse than 0.2 nm Dimensions no more than 205x125x150 mm Weight not more than 3 kg Supply voltage 90-120 / 187-242 V Power consumption not more than 12 W Current frequency 50/60 Hz
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury analyzer "RA-915M"
Mercury analyzer "RA-915M"
Technical specifications: Measuring range of mass concentration of mercury vapors in the air, ng/m3 from 20 to 20000 Limits of permissible basic relative error, d0, % ± 20 The limit of permissible relative standard deviation of the analyzer output signal, %5 The limit of the permissible value of the mean square deviation (SKO) of the zero signal, ng/m3 2 Drift of the zero signal of the analyzers in 5 minutes, ng/m3, no more than 2 The limit of permissible change of analyzer readings for 8 hours in fractions of d0 0.5 Time to establish the readings, s, no more than 20 Time of analyzer output to the mode, min, no more than 20 Volumetric flow rate of the analyzed air at the analyzer inlet, dm3/min, not less than 10 Volumetric air flow at the outlet of the gas analyzer system with the inlet blocked, dm3/min, not more than 0.3 Absorption coefficient of mercury vapor by the built-in sorption filter, %, not less than 98 The limit of permissible additional error due to changes in ambient temperature within the operating range for every 10 ° C, in fractions of d0 0.5 The analyzers are powered by a built-in AC battery voltage (220 ±22) In the frequency (50 ±1) Hz Power consumption, In × A, not more than 35 Continuous operation time of the analyzers from the built-in battery, h, at least 8 Overall dimensions of the analyzers, mm, no more than 470x110x220 Mass of analyzers, kg, not more than 7 Reliability indicators average time to failure, h, at least the full average life from the built-in AC battery voltage (220 ± 22) In the frequency (50 ±1) Hz Power consumption, In × A, not more than 35 Continuous operation time of the analyzers from the built-in battery, h, at least 8 Overall dimensions of the analyzers, mm, no more than 470x110x220 Mass of analyzers, kg, no more than 7 Reliability indicators average time to failure, hours, at least full average service life, years, at least 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury analyzer "RA-915M" with the prefix "URP"
Mercury analyzer "RA-915M" with the prefix "URP"
Technical specifications: Continuous operation time 8 hours The dimensions of the analyzer are 470x220x110 mm The dimensions of the console are 340x240x120 mm Analyzer weight 7.5 kg The weight of the console is 5.5 kg Power supply 220 V Supply voltage of RA-915M: (220 ±22) V, 50 Hz URP supply voltage: (220±22) V, 50 Hz Power consumption of RA-915M: 35 VA URP power consumption: 220 VA Current frequency 50 Hz
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury analyzer "RA-915M" with pyrolytic prefix "PYRO-915+"
Mercury analyzer "RA-915M" with pyrolytic prefix "PYRO-915+"
Technical specifications: The upper limit of the measurement range is 5 mg/kg Analysis time 1-5 min Permissible sample weights are 10-500 mg The weight of the console is 17 kg Air pumping speed 1-3 l/min Dimensions and weight of the analyzer 470x210x110 mm; 7.5 kg Power supply of the PIRO-915+ 220 V, 700 W Analyzer power supply 220 V, 15 W Dimensions of the power supply and pumping unit no more than 400x280x135 mm The dimensions of the thermal camera unit and the remote optical unit are no more than 430x340x135 mm The upper limit of the measurement range for sample weighting is 20 mg 200 mg/kg
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Capillary electrophoresis systems "KAPEL®-104T"
Capillary electrophoresis systems "KAPEL®-104T"
Technical specifications: The working wavelength of detection, nm 254 The range of variation of the operating voltage on the capillary, kV from 1 to 25 The detection limit of benzoic acid (with positive polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, mcg/ cm3, not more than 0.8 The limit of detection of chloride ions (with a negative polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, micrograms / cm3, not more than 0.5 The limit of the permissible relative mean square deviation (SKO) of the output signal over the peak area, %5 The limit of the permissible relative mean square deviation (SKO) of the output signal for 8 hours of operation, % 6.5 Operating mode setting time, min, no more than 30 Power supply of systems from the AC network with voltage, V; frequency, Hz. 220 ±22 50 ±1 Power consumption consumed by the system, In ×A, no more: 150 Overall dimensions (LXC), mm, no more 420x460x360 Weight, kg, not more than 25
Lumeks
Saint Petersburg
Produced in: Saint Petersburg