Lumeks

Lumeks

40 products
View:
Telephone number:
Address:
Russia, Saint Petersburg, null, 1, letter Bnull
Адрес:
Russia, Saint Petersburg, null, 1, letter Bnull
  • Selected: 0
    Applying
  • Selected: 0
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • 9
    Applying
  • 11
    Names
  • 1
    Manufacturer
  • 1
    Made in
  • 11
    Additional
View:
38 products
The "FLUORATE®-411" alarm
The "FLUORATE®-411" alarm
Technical specifications: Analog data output 0-0.5 W or 4-20 mA The pressure of the measured water is 0.1-8 atm The reading range is 0-30 mg/l The length of the light guide is 1.5 m The temperature of the controlled environment is 0 ... +100 °C Ambient temperature 0 ... +55 °C Dimensions 300x300x150 mm Weight 15 kg Power supply ~ 220 V Power consumption not more than 15 W Current frequency 50 Hz
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Microparticle analyzer "SKAT-1"
Microparticle analyzer "SKAT-1"
Technical specifications: The time of one measurement is not more than 60 seconds Output of results to digital display board, RS485, RS232; current loop 4-20 mA, (0-20) mA The pressure in the flow is 0.1-10 atm. The range of detectable concentrations of suspended particles is 0.02-5 SCAT-1(VC); 0.1-100 SCAT-1(n) mg/l Execution B4, P1, N1 according to GOST 12997-84 Category of climatic execution UHL4 according to GOST 15150-69 Relative humidity at +25 ° C is not more than 80% The error of photometry per channel is not more than 1% The size of the analyzed microparticles is 0.5-50 microns Display modes NORM, ALARM, LIMIT The temperature of the analyzed flow is from +0.5 to +50 °C Ambient temperature from +0.5 to +50 °C Atmospheric pressure 84-106.7 kPa The warranty period of operation is 1 year Average service life of at least 5 years Dimensions 300x400x150 mm Weight not more than 20 kg Power supply 187-242 V, 50 ± 1 Hz from an autonomous source, 12 V Power consumption 100 W
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury analyzer "RA-915M" with the prefix "RP-91NG"
Mercury analyzer "RA-915M" with the prefix "RP-91NG"
Technical characteristics: The set-top box is powered by AC (220 ± 22) V, 50 Hz Power consumption, VA, no more than 35 Continuous operation time, h 8 Overall dimensions: (LxWxH), mm, no more than 320x290x160 The weight of the console, kg, not more than 6.5 Air consumption, dm3/min 2 ... 5
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Infrared analyzer "InfraLUM® FT-12"
Infrared analyzer "InfraLUM® FT-12"
Technical specifications: Measurement time, 80 seconds Standard sample volume in a cuvette, 50 ml Spectral range, cm-1 from 8700 to 13200 Spectral resolution, cm-1, no more than 10 The limit of the permissible value of the absolute error of the wave number scale, cm-1 ±0,5 Analyzer warm-up time, min, no more than 30 Continuous operation time of the analyzer, h, at least 8 Overall dimensions, mm, no more than 530x450x380 Weight, kg, not more than 32 Power supply of analyzers from the AC network: AC power supply voltage, V frequency, Hz (220 ±22) (50 ±1) Power consumption, V× A, not more than 110 Average time to failure, h, not less than 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Infrared analyzer "InfraLUM® FT-12" with a wake-up module
Infrared analyzer "InfraLUM® FT-12" with a wake-up module
Technical specifications: Measurement time, sec. 80 Standard sample volume in a cuvette, 500 ml Spectral range, cm-1 from 8700 to 13200 Spectral resolution, cm-1, not more than 10 The limit of the permissible value of the absolute error of the wavenumber scale, cm-1 ± 0.5 The level of positive and negative pseudo-scattered light caused by the nonlinearity of the photodetector system (relative to the maximum signal), %, not more than ± 0.25 Analyzer warm-up time, min, no more than 30 Continuous operation time of the analyzer, h, not less than 8 Overall dimensions, mm, not more than 530x485x495 Weight, kg, not more than 32 Power supply of analyzers from the AC network: AC power supply voltage, V frequency, Hz (220 ±22) (50 ±1) Power consumption, V× A, not more than 110 Average time to failure, h, not less than 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Universal biochemical analyzer "FLUORAT®-02-ABLF-T"
Universal biochemical analyzer "FLUORAT®-02-ABLF-T"
Technical characteristics: Consumption of working reagents 1.0–2.0 ml – for standard filling cuvette K10 from 400 ml – for photometric techniques Filters for photometer mode, nm built-in interference filters 340, 405, 505 ,545, 575, 630 spectral half-width of 10 nm Filters for fluorimeter and chemiluminometer modes on request, in the spectral range of 270-850 nm Chemiluminescence channel sensitivity 10000 photons per second Optical density measurement range, E.O.P. 0-2.20 Photometric channel accuracy, %2 Memory of 100 measurement programs Temperature control of the measuring cell (for photometer and chemiluminometer modes) built-in thermostat on the Peltier element: 25, 30, 37 OC; accuracy ± 0.2 oC Volume of the flow cuvette, mkl 80 Pump type (only for photometer mode) peristaltic pump with programmable liquid supply volume Productivity, analyses/hour up to 100 (by the endpoint method) Information output liquid crystal display and personal computer Power supply, 220 ± 22 Dimensions, mm 430x350x160 Weight, kg 10
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Biochemical analyzer (photometer) "BIALAB-100"
Biochemical analyzer (photometer) "BIALAB-100"
Technical specifications: Methods of analysis optical density, endpoint, kinetics, fixed time, nonlinear, two-wave, turbidimetry Light source halogen lamp (12 V, 20 W) with a slow start system to increase the service life Built-in interference light filters 340, 405, 505, 546, 578, 630nm; spectral half-width 12 nm The optical density measurement range is 0-2.5 E.O.P. The measurement error of optical transmission is not more than 1 % Memory of 100 measurement programs Temperature control of the measuring cell built-in thermostat with Peltier element: 25, 30, 37 ° C; accuracy ± 0.2 ° C Sample incubation thermostat external, for 16 vials The volume of the flow cell is 32 µl Consumption of the working reagent from 250 µl Built-in matrix printer, printing on plain paper with a tape width of 56 mm Liquid crystal display: 4 lines of 20 characters each Productivity of up to 100 analyses/hour by the endpoint method Dimensions and weight no more than 355x355x185 mm; 8.5 kg
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Optical recorder of oil films "CRAB-1"
Optical recorder of oil films "CRAB-1"
Technical specifications: Sensitivity (minimum thickness of recorded oil films) from 0.5 microns The root-mean-square slope of the water surface up to 20 ° Distance from the receiving device up to 1000 m Sensor power supply 100-240 V, 50-60 Hz Power consumption up to 3 watts Ambient air temperature from -10 to +50 °C Humidity up to 100% (rain) Distance to the water surface 0.5–20 m Dimensions 120x180x120 mm Weight up to 1.5 kg
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
NEVA-412 alarm system
NEVA-412 alarm system
Technical specifications: Analog output 0-0.5 V (4-20 mA on request) Overall dimensions 320x255x175 mm Water pressure 0.1-3 atm The door of the alarm opens to the left side Measuring range 0-30 ppm Alarm relay contacts dry contact (power up to 2A/250V) Control relay contacts dry contact (power up to 2A/250V) Linearity +(-)2% in the range of 1-20 ppm Trigger threshold setting from 1 to 30 ppm (in increments of 1 ppm) Connecting dimensions of flanges external thread 1/2" Signal norm green LED Alarm red LED Degree of protection IP X4 The temperature of the controlled environment is +4 ... +55 °C Ambient temperature 0 ... +55 °C Measurement accuracy in accordance with resolution MERS.107(49) CF type flash memory card (software included) at least 32 MB RS485 digital output (on request) Power supply 200/240 V, 50/60 Hz (on request = 24 V) Weight not more than 10.5 kg Power consumption < 6 W
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Analyzer of sodium hypochlorite in water "AGH-3"
Analyzer of sodium hypochlorite in water "AGH-3"
Technical specifications: Output of results to digital display board, RS485, RS232; current loop 4-20 mA (0-20) mA The pressure in the flow is 0.1-10 atm. The range of detectable concentrations is 20-200 g/l Version B4, P1, N1 according to GOST 12997-84 Category of climatic performance UHL4 according to GOST 15150-69 Relative humidity at + 25 °C 80 % Display modes NORM, ALARM, LIMIT The temperature of the analyzed flow is from +0.5 to +25 °C Ambient temperature from +5 to +35 °C Atmospheric pressure 87-107 kPa The warranty period of operation is 1 year Average service life of at least 3 years Dimensions - electronic block - optical unit no more than 300x400x150 mm no more than 120x90x90 mm Weight - electronic block - optical unit no more than 10 kg not more than 2 kg Power supply 187-242 V, 50 ± 1 Hz, from an autonomous source, 12V Power consumption 100 W
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Infrared Fourier spectrometer "InfraLUM® FT-08"
Infrared Fourier spectrometer "InfraLUM® FT-08"
Technical specifications: Operating spectral range, cm-1 from 400 to 7800 Spectral resolution, cm-1, not more than 0.7 The limit of the absolute error of the wavenumber scale, cm-1 ± 0.05 Signal-to-noise ratio (RMS) for the wavenumber 2150 cm-1, determined in the range ± 50 cm-1 for a resolution of 4 cm-1 and an accumulation time of 60 s, at least 40,000 The limit of deviation of the 100% transmission line from the nominal values for the wave number 2150 cm-1, determined in the range ± 50 cm-1, % ± 0.2 The level of positive and negative pseudo-scattered light caused by the nonlinearity of the photodetector system, % ± 0.25 The time of setting the operating mode of the spectrometers, h, no more than 2 Continuous operation time of spectrometers, h, not less than 8 Power consumption, In × A, not more than 65 Overall dimensions, mm, not more than 580x550x340 Weight, kg, not more than 32 Average time to failure, h, not less than 2500 Average service life of the spectrometer, years, at least 5
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Monochromator "MHD-2"
Monochromator "MHD-2"
Technical specifications: Range of operation 280-710 nm Diffraction grating (replica) 1250 strokes per millimeter The area of maximum energy concentration 350-450 nm The working order of the spectrum is the first The signal-to-noise ratio on the line is 632.8 nm when detuning from the center of the line by ± 3.3 nm is not worse than 3 * 106 times The slits are fiber optical fibers with a diameter of 200 microns, stacked in 1 row. The height of the slits is 5 mm The resolution of the monochromator with these slits is not worse than 0.34 nm The accuracy of the wavelength setting is not worse than 0.2 nm Dimensions are not more than 335 x 153 x 240 mm Weight is not more than 8 kg Supply voltage 187-242 V Power consumption not more than 12 watts Current frequency 49-51 Hz
Lumeks
Saint Petersburg
Produced in: Saint Petersburg