Accessories

357 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 20
    Applying
    Loading...
  • 92
    Names
    Loading...
  • 37
    Manufacturer
    Loading...
  • 24
    Made in
    Loading...
  • 31
    Additional
    Loading...
View:
357 products
BTS 200/400 Lenses
BTS 200/400 Lenses
Technical specifications Material: S-TIH53 (Ohara) Length, mm: 12 Height, mm: 1.0±0.01 Thickness, mm: 1.9±0.1 Refractive index, mm: 1.823 Optical aperture, mm2: 10.5*0.45 Back focal length, mm: 0.09 Transmission, %: >99.5 Pitch, mm: 0.4 Antireflection coating, nm at one of the wavelengths from the range: 400-1500 Numerical aperture: FA: 0.6, SA:0.09 Surface quality at λ = 633 nm: λ/4 Residual deviation at full angle FW1/e2 mrad: <7, <10, <13
INZHEKT
Saratov
Produced in: Saratov
Temperature equalization unit THERMOTEST-B1
Temperature equalization unit THERMOTEST-B1
It is designed to improve short-term temperature stability during verification and calibration of electronic thermometers LT 300 (except LT-300-F), LT and ExT-01/1 in calibration thermostats TERMOTEST 100, TERMOTEST-100-40, TERMOTEST 05 and TERMOTEST-05-1.
Produced in: Tomsk
Piezoelectric vibration measuring transducers DN-3-M1, DN-3-M1 B6
Piezoelectric vibration measuring transducers DN-3-M1, DN-3-M1 B6
Vibration transducers DN-3-M1 are designed to measure vibration by converting mechanical vibrations into electrical signals proportional to the vibration acceleration of an oscillating object. Vibration converters DN-3-M1 are used in conjunction with vibration measuring devices in factory and laboratory conditions.
VIBROPRIBOR
Yaroslavl
Produced in: Yaroslavl
LB33-187/1K Basket
LB33-187/1K Basket
It is designed for thermostating glasses, flasks and evaporating cups with samples in the laboratory bath LB33 and LB33-Sh. Overall dimensions 310x250x210 mm Weight 2.0 kg
Produced in: Tomsk
Liquid flask with adjustable thickness of the test liquid layer
Liquid flask with adjustable thickness of the test liquid layer
A liquid flask with an adjustable layer thickness of the liquid under study is made in the form of an optical-mechanical attachment installed in the cuvette compartment of the FT-801 spectrometer. It contains focusing optics, removable holders of two windows-substrates with a diameter of 10 mm and two adjusting screws placed on the upper panel of the console housing and designed to set the required gap between the windows. A liquid of any degree of viscosity is pre-applied in the form of a small drop to the lower window and then, in the process of smooth convergence of the windows, evenly fills the gap between them. By rotating the adjusting screws and observing the transmission spectrum online, the user has the opportunity to set the desired thickness of the liquid layer, guided by the overall intensity of the entire spectrum or by the intensity of specific absorption bands. In the presence of calibration, which is easy to create using the ZaIR 3.5 program for several samples with a known concentration, the cuvette allows quantitative measurements. The flask is indispensable in the analysis of mixtures containing impurities in small proportions. Technical specifications Transmission in the operating range of the spectrum, % of the input signal at least 50 The recommended number of scans when registering spectra is 16 Time of spectrum registration at 16 scans (resolution 4 cm-1), sec 20 Minimum volume of the studied liquid, mm3 1 The diameter of the focus spot, mm 3 Overall dimensions, mm 200×90×160 Weight, kg 1,1 The figure shows several spectra of the viscous lubricant "Buxol", illustrating the process of selecting the thickness of the sample layer between the windows. The measurement process has a high expressiveness and reproducibility, inexpensive replaceable substrate windows are used, the system is easy to configure and clean, a very small amount of sample is required to obtain high-quality spectra.
SIMEKS
Novosibirsk
Produced in: Novosibirsk
Tees
Tees
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
Produced in: Kazan
Centering rings (stainless steel) with a metal-ceramic filter (stainless steel) and O-ring of circular cross-section
Centering rings (stainless steel) with a metal-ceramic filter (stainless steel) and O-ring of circular cross-section
The ISO-KF connection (DIN 28 403 and ISO 2861) allows quick installation and replacement of components in vacuum systems. The connection consists of two symmetrical ISO-KF flanges (1), a centering ring with an O-ring seal (2) and a quick-release clamp (3). High-vacuum ISO-KF connections can be mounted without using a tool by simply turning the nut of the quick-release clamp.
Produced in: Kazan
A set of BNTI devices-05-04- K
A set of BNTI devices-05-04- K
It is used for determining the low-temperature characteristics of petroleum products and organic chemical products in accordance with the State Standard 20287 (method A), EN 23015, ASTM D97 and GOST 18995.5.
Produced in: Tomsk
FNCH-78
FNCH-78
Structurally, waveguide LPF 37-78 GHz are made on metal plates located in the center of the E-plane of the waveguide. These LFS can be used in conjunction with waveguide bandpass filters to increase the suppression of spurious signals and expand the upper band of the barrier. Basic properties Low bandwidth losses; A wide barrage strip. Operating conditions Operating temperature range from minus 10 up to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 3.6×1.8 Bandwidth Fh-Fb at the level of -1 dB, GHz 60-78 The barrier band at the level of -30 dB, GHz 85-120 Bandwidth loss, 0.5-1.2 dB
Produced in: Moscow
CRYO basket-VT-06-K
CRYO basket-VT-06-K
It is designed to accommodate thermostatically controlled objects in the inner bath of the liquid low-temperature thermostat CRYO VT 06. The height-adjustable bottom allows objects to be immersed in the coolant to the required depth. Internal dimensions 300x200x120 mm Weight 2.7 kg
Produced in: Tomsk
Stand THERMOTEST-100-P
Stand THERMOTEST-100-P
The stand provides convenience when taking measurements, allowing you to set the thermometers at eye level. Designed for calibration thermostat THERMOTEST-100. Overall dimensions 400x625x490 mm
Produced in: Tomsk