Accessories

360 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 20
    Applying
    Loading...
  • 93
    Names
    Loading...
  • 37
    Manufacturer
    Loading...
  • 24
    Made in
    Loading...
  • 26
    Additional
    Loading...
View:
360 products
CRYO-VIS-T-05-P stand
CRYO-VIS-T-05-P stand
It provides convenience in measurements, allowing you to install viscometers at eye level. The wheels make it easy to move heavy thermostats when needed. Overall dimensions 650x450x550 mm
Produced in: Tomsk
GC-MS CHROMATOGRAPH SYSTEM "CRYSTALLUX-4000M" WITH MSD "MAESTRO-AMC"
GC-MS CHROMATOGRAPH SYSTEM "CRYSTALLUX-4000M" WITH MSD "MAESTRO-AMC"
GC and MS interface Capillary direct interface, independent temperature control (50-300 0 S) The filament of the cathode (filament) is a double filament for electron ionization (EI), the maximum current is 300 µA. Double thread increases the service life. Two independent switchable cathodes Temperature of the ion radiation source Independent heating and temperature control, maximum value 350 0 C (adjustable) Transparent polymer window on the front panel there is no visual control of the state of the cathodes Ion radiation source Lenses made of ceramic and with a patented coating enhance the focusing effect, which significantly increases the efficiency of ionization, an electrode with a patented reflective surface improves focusing Tubular lenses enhance the focusing effect, which significantly increases the ionization efficiency, an electrode with a patented reflective surface improves focusing Energy ionization 10-100 eV The mass analyzer is a high-precision quadrupole with a filter that reduces the contamination of the main quadrupole and eliminates the influence of photonic noise on the analysis High-precision molybdenum quadrupole with prequadrupole (replaceable), which reduces the contamination of the main The detector is an electronic multiplier with a high-voltage secondary emiting electrode (dinode) of high energy 3D geometry to improve sensitivity. The amplifier of weak voltage signals effectively reduces network noise, improves the signal-to-noise ratio during electron ionization and provides a large linear dynamic range. It is possible to install an additional detector Mass range 2.0-1200 a.e.m. 1.5-1050 a.e.m. Mass stability Less than 0.1 a.e.m. for 48 hours Signal ratio noise At least 1500:1 with mass to charge (m/z) 272 At least 150:1 with mass to charge (m/z) 272 (with signal filtering 500:1) Linearity Not less than 107 Not less than 106 Precision < 5% RSD 9n=7, SIM, 100 fg OFN) no System sensitivity IDL < 10 fg (SIM mode, OFN according to m/z 272) no Maximum scanning speed 20000 a.m./s 11000 a.m./s Operating modes Scap, SIM, Scan/SIM, MicroScan and the innovative Flexible-SIM algorithm for finding trace amounts of components no Setting Automatic setting MSD on the PFTBA spectrum and m/z control of oxygen, nitrogen and water no Pumping pump Oil plate-rotor vacuum pump with a pumping speed of 66 l/min Oil plate-rotor vacuum pump with a pumping speed of 165 l/min Turbo pump Turbo molecular pump with magnetic levitation, with a pumping speed of 85 l/s (can be replaced by 300 l/s) Turbo molecular pump with magnetic levitation, with a pumping speed of 71 l/s (possible replacement by 260 l/s) RF detector power Allows you to use three points for calibration in the entire mass range and get good linearity in scanning mode Software Rus./ Eng. The ability to search and extract structural, graphical formulas. Library of 240,000 spectra. The ability to isolate individual components from overlapping peaks. In addition to spectra and compounds, the library contains the element name, formula, molecule structure, molecular weight, CAS number, analysis conditions, synonyms, and estimated or measured retention readings. The NIST EI library contains: drugs, metabolites and poisons, pesticides and fungicides, organic substances present in soil, water and air, amino acids, di- and tripeptides, common sample pollutants, common analytical derivatives, etc. Ethernet interface, remote access function implemented Touch screen Display of parameters and monitoring of system status no Built -in power supply Allows you to turn off the detector in normal mode if there is no power supply violation
Produced in: Yoshkar-Ola, Mari El
Spectroscopy Cells D=28, L=100
Spectroscopy Cells D=28, L=100
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
Thermal Conductivity Detector(accident)
Thermal Conductivity Detector(accident)
It is used to determine hydrogen, oxygen, CO and combustible hydrocarbon gases, and its sensitivity to these compounds is higher than the sensitivity of an accident. The most widespread TCD was obtained for the analysis of hydrogen and oxygen, tk. its sensitivity to them is almost an order of magnitude higher than that of an accident. The principle of operation is based on fixing the thermal effect of catalytic combustion of the sample on the surface of the platinum filament. Technical characteristic: 1.8*10`10 g/ml of hydrogen
Produced in: Yoshkar-Ola, Mari El
LA-230 cooling heat exchanger
LA-230 cooling heat exchanger
Inner diameter, mm 6 Outer diameter, mm 8
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Liquid flask with adjustable thickness of the test liquid layer
Liquid flask with adjustable thickness of the test liquid layer
A liquid flask with an adjustable layer thickness of the liquid under study is made in the form of an optical-mechanical attachment installed in the cuvette compartment of the FT-801 spectrometer. It contains focusing optics, removable holders of two windows-substrates with a diameter of 10 mm and two adjusting screws placed on the upper panel of the console housing and designed to set the required gap between the windows. A liquid of any degree of viscosity is pre-applied in the form of a small drop to the lower window and then, in the process of smooth convergence of the windows, evenly fills the gap between them. By rotating the adjusting screws and observing the transmission spectrum online, the user has the opportunity to set the desired thickness of the liquid layer, guided by the overall intensity of the entire spectrum or by the intensity of specific absorption bands. In the presence of calibration, which is easy to create using the ZaIR 3.5 program for several samples with a known concentration, the cuvette allows quantitative measurements. The flask is indispensable in the analysis of mixtures containing impurities in small proportions. Technical specifications Transmission in the operating range of the spectrum, % of the input signal at least 50 The recommended number of scans when registering spectra is 16 Time of spectrum registration at 16 scans (resolution 4 cm-1), sec 20 Minimum volume of the studied liquid, mm3 1 The diameter of the focus spot, mm 3 Overall dimensions, mm 200×90×160 Weight, kg 1,1 The figure shows several spectra of the viscous lubricant "Buxol", illustrating the process of selecting the thickness of the sample layer between the windows. The measurement process has a high expressiveness and reproducibility, inexpensive replaceable substrate windows are used, the system is easy to configure and clean, a very small amount of sample is required to obtain high-quality spectra.
SIMEKS
Novosibirsk
Produced in: Novosibirsk
GAS SAMPLER
GAS SAMPLER
They are used for sampling natural and liquefied gas. In the company "Meta-chrome" you can buy the following gas samplers: PGO-50M; PGO-400; BDP 12-2-9,8 (aluminum, subcompact); PU. The PGO-50 M, PGO-400 and PU models are used to take samples of liquefied hydrocarbon gases that are affected by the overpressure of stationary tanks and or their own vapors. Sampling is carried out according to GOST 14921-78. The BTP 12-2-9.8 device is used for sampling, storing and transporting samples of gases that are under pressure. The device is made of aluminum and is designed for a small liter. Sampling is carried out according to GOST 31370-2008. INDICATOR BDP7 BDP7 BDP12 BDP12 BDP16 PGO-400 PGO-50M Volume, l. 0,7 1 2 4 10 0,4 0,05 Outer diameter, mm 70 70 120 120 160 50 35 Length, mm 360 480 368 593 800 400 325 Working pressure, MPa 9.8 5.0 9.0 The number of refills up to the operating pressure, times at least 5000 Case material AMg6M 12X18
Produced in: Yoshkar-Ola, Mari El