Device for lifting and lowering samples LA-220
Device for lifting and lowering samples LA-220
Designed for immersion of objects in the baths of LOIP LT thermostats and LOIP LB-200 precision thermostatic baths to a predetermined depth. Thermostatable objects are placed on a movable pallet, which can be fixed at any required depth. The device is installed on the casing of thermostats and precision thermostatic baths instead of a hinged lid and is equipped with its own removable lid. Bath volume, l 17 and 24 Pallet size, mm 260x320 Maximum immersion depth, mm 200
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Set of devices for CRYO-VIS-T-06 the State Standard 20287 method B
Set of devices for CRYO-VIS-T-06 the State Standard 20287 method B
It is used in determining the pour point of petroleum products in accordance with the State Standard 20287 (method B).
Produced in: Tomsk
Cell for Spectroscopy Cube S=6
Cell for Spectroscopy Cube S=6
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
Bracket for mounting the AE-4/AE-5 disstillator on the wall
Bracket for mounting the AE-4/AE-5 disstillator on the wall
from 3 600 ₽
The bracket for mounting the distiller provides the possibility of not only desktop, but also wall-mounted installation of the aquadistillator at the required height.
Livam
Belgorod
Produced in: Belgorod
Microassembly RB1S8KN009
Microassembly RB1S8KN009
Two-channel analog switch with signal summation function Designed for use in oscilloscopes with a bandwidth up to 350 MHz. Technical specifications: The value of the voltage between the outputs of the switch at load resistance RN = (50 ± 2.5) ohms and opening voltages UU1 = (2.0 ± 0.2) V and locking UU2 = (4.2 ± 0.2) V channels supplied alternately to the corresponding inputs (start 1, start 2) of the switches must be: in the absence of an input signal from minus 0.1 to plus 0.1 V with an input signal UC = (0.3 ± 0.05) V supplied to one of the inputs of the open channel (0.45 ± 0.1) V with an input signal UC = (0.3 ± 0.05) V supplied to one of the inputs of both open channels (0.45 ± 0.1) V
MNIPI
Minsk
Produced in: Belarus, Minsk
Photoionization (PID)
Photoionization (PID)
Partially universal detector. It is used for the analysis of most organic compounds, including aromatic and aliphatic (except methane) hydrocarbons, heterocyclic compounds, phenols, phthalates, pesticides, amines, ketones, aldehydes, esters, mercaptans. It does not register compounds whose ionization threshold is higher than 10.2 eV (for example, acetonitrile, methanol). Technical characteristic: 5.0*10`13 g/s for benzene
Produced in: Yoshkar-Ola, Mari El
Thermal Conductivity Detector(accident)
Thermal Conductivity Detector(accident)
It is used to determine hydrogen, oxygen, CO and combustible hydrocarbon gases, and its sensitivity to these compounds is higher than the sensitivity of an accident. The most widespread TCD was obtained for the analysis of hydrogen and oxygen, tk. its sensitivity to them is almost an order of magnitude higher than that of an accident. The principle of operation is based on fixing the thermal effect of catalytic combustion of the sample on the surface of the platinum filament. Technical characteristic: 1.8*10`10 g/ml of hydrogen
Produced in: Yoshkar-Ola, Mari El
Set of devices GOST 11851 method A
Set of devices GOST 11851 method A
It is intended for placement in the BF bath and is used in determining the mass fraction of paraffins in oil in accordance with the method A of the State Standard 11851.
Produced in: Tomsk
Thermionic (TID)
Thermionic (TID)
Selective detector for organophosphorus and nitrogen compounds. It is also sensitive to compounds containing C, Az, but to a lesser extent. The sensitivity depends on the number of heteroatoms in the molecule. Selectivity to hydrocarbons is 104 for nitrogen, and 105 for phosphorus Technical characteristic: 2.0*10-13 m/s nitrogen 1.5*10`14 g/s for phosphorus
Produced in: Yoshkar-Ola, Mari El
LB63-32/50K Basket
LB63-32/50K Basket
The height-adjustable bottom allows the tubes to be immersed in the coolant to the required depth. Overall dimensions 515x310x215 mm Weight 2.8 kg
Produced in: Tomsk