TWO-STAGE THERMAL DESORBER TDS-4
TWO-STAGE THERMAL DESORBER TDS-4
The composition of the TDS-4 includes the thermal desorber itself (the thermostat of the sorption tube, a cryolovushka, an automatic switching valve, a touch control panel), a heated transition line that is installed in the evaporator\ Technical characteristics of TDS-4 Temperature of thermal desorption, 0C to 400 The heating rate of the sorption tube, 0C/min up to 500 Trap temperature, 0C from minus 25 to 400 Trap heating speed, 0C to 2000 The method of heating the trap is direct Tap heating temperature, 0C to 250 Transition line heating temperature, 0C to 250 Continuous operation mode Dimensions of the sorption tube, (diameter; length), mm. Material glass, stainless steel 5/114 (on request 6/115, 6,3/89 and their combinations) Tube material glass or stainless steel (SS316) Method of trap cooling without using liquid refrigerant The number of regulated gas flows is not less than 2 There is an automatic leak test function There is a function of automatic purging of the sorption tube Electric power supply from 187 to 242 V, 50 Hz Power consumption, W not more than 700
Produced in: Yoshkar-Ola, Mari El
Basket VT12-18/24K
Basket VT12-18/24K
It is designed to accommodate twenty-four tubes with a diameter of 18 mm during thermostating in the inner bath of the liquid thermostat VT12 or VT12-2. The height-adjustable bottom allows the tubes to be immersed in the coolant to the required depth. Overall dimensions 280x165x210 mm Weight 1.1 kg
Produced in: Tomsk
Adapters for CF / ISO-KF SVB connections
Adapters for CF / ISO-KF SVB connections
ConFlat (CF) standard connections are used еo ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
Produced in: Kazan
SAC500 lenses
SAC500 lenses
Technical specifications Material: S-TIH53 (Ohara) Length, mm: 5.8±0.02 Height, mm: 1.5±0.02 Thickness, mm: 0.55±0.01 Refractive index, mm: 1.823 Pitch, mm: 0.5 Radius, mm: 1.49 Effective focal length, mm: 1.81 Back focal length, mm: 1.5 Transmission, %: >99.5 Antireflection coating, nm at one of the wavelengths from the range: 400-1500 Numerical aperture: 0.09 Surface quality at λ = 633 nm% λ/4 Residual deviation in the full angle FW1/e2 (for non-linear deviation of the laser diode), mrad: 90.0
INZHEKT
Saratov
Produced in: Saratov
FNCH-78
FNCH-78
Structurally, waveguide LPF 37-78 GHz are made on metal plates located in the center of the E-plane of the waveguide. These LFS can be used in conjunction with waveguide bandpass filters to increase the suppression of spurious signals and expand the upper band of the barrier. Basic properties Low bandwidth losses; A wide barrage strip. Operating conditions Operating temperature range from minus 10 up to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 3.6×1.8 Bandwidth Fh-Fb at the level of -1 dB, GHz 60-78 The barrier band at the level of -30 dB, GHz 85-120 Bandwidth loss, 0.5-1.2 dB
Produced in: Moscow
Flame Photometric(FD)
Flame Photometric(FD)
Selective detector for phosphorus and organosulphide compounds. It is used mainly for the analysis of sulfur-containing substances (hydrogen sulfide, mercaptans, thiophenes, etc.). The sensitivity for sulfur reaches 0.1. ppm. In addition, PFD has sufficient sensitivity and selectivity to compounds containing nitrogen, boron, tin, chromium, selenium, germanium, as well as CO, POPS, MgOx, $02, Ma, NOT C52. The selectivity of 5-containing compounds to hydrocarbons is 105. Technical characteristic: 8,0*10-13 g5/s by sulfur 1.0*10`13 g/s for phosphorus
Produced in: Yoshkar-Ola, Mari El
CF flanges with a branch pipe
CF flanges with a branch pipe
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
Produced in: Kazan
Flame Ionization (PID) for chromatograph
Flame Ionization (PID) for chromatograph
The most common, universal detector that is suitable for the analysis of a wide range of organic compounds. The sensitivity depends mainly on the number of carbon atoms. In combination with a methanator, it allows the analysis of carbon oxides at the level of 0.1 Rt. The level of fluctuation noise is up to 50 MV, the maximum signal is up to 2500 V. Technical characteristic: 1.2*10712 gs/s for hydrocarbons
Produced in: Yoshkar-Ola, Mari El
Basket VT14-K-PZH25
Basket VT14-K-PZH25
The height-adjustable bottom allows the tanks to be immersed in the coolant to the required depth. Internal dimensions 150x90 mm Weight 1 kg