Accessories

358 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 20
    Applying
    Loading...
  • 93
    Names
    Loading...
  • 36
    Manufacturer
    Loading...
  • 23
    Made in
    Loading...
  • 26
    Additional
    Loading...
View:
358 products
Probe (probe intake) capillary
Probe (probe intake) capillary
The probe is designed for use with leak detectors of any type, which have an input port NW (KF) 25 and provide a counterflow mode of operation.
NPO "Gelikon"
Saint Petersburg
Produced in: Saint Petersburg
Stand THERMOTEST-100-P
Stand THERMOTEST-100-P
The stand provides convenience when taking measurements, allowing you to set the thermometers at eye level. Designed for calibration thermostat THERMOTEST-100. Overall dimensions 400x625x490 mm
Produced in: Tomsk
Basket T40-K
Basket T40-K
It is designed to accommodate thermostatically controlled objects in the inner bath of the T40 liquid thermostat. A basket with a height-adjustable bottom allows objects to be immersed in the coolant to the required depth. Overall dimensions 305x305x390 mm Internal dimensions 260x250mm Weight 2.8 kg
Produced in: Tomsk
Stand VT-ro-P
Stand VT-ro-P
Stand for thermostats VT ro 01, VT ro 02 and CRYO-VT ro 03. It provides convenience in measurements, allowing you to install cylinders for hydrometers at eye level. Overall dimensions 400x625x490 mm
Produced in: Tomsk
Flanges with a cone
Flanges with a cone
Size of Dn: 16,25,40.
Produced in: Kazan
LIQUEFIED GAS METERING VALVE
LIQUEFIED GAS METERING VALVE
The metering valve for the analysis of liquefied gas (KDSG) is designed for the introduction of liquefied gas or other liquid under excessive pressure into the evaporator of the chromatograph. KDSG is a 4-way crane, in which a dose of a certain volume is installed. The tap is installed on the evaporator of the chromatograph. A dose of any volume can be installed on the tap. Dose change can be performed by the operator. The amount of the dose volume is indicated on the tag. Technical specifications The dose volume is from 0.25 to 4.0 µl (at the request of the consumer, the dose volume can be increased up to 10 µl). The tap temperature is no more than 150 °C. The pressure in the crane line is not more than 0.48 MPa. The angle of rotation of the crane handle is 90 °C.
Produced in: Yoshkar-Ola, Mari El
LA-230 cooling heat exchanger
LA-230 cooling heat exchanger
Inner diameter, mm 6 Outer diameter, mm 8
LOIP
Saint Petersburg
Produced in: Saint Petersburg
CF transition flanges
CF transition flanges
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
Produced in: Kazan
PS-78 (waves.)
PS-78 (waves.)
Strobe converters are used as input devices of radio measuring equipment: amplifasometers, frequency meters, spectrum analyzers, circuit analyzers, etc.; in systems of synchronization and frequency stabilization of microwave generators, heterodynes, frequency synthesizers. Basic properties: Wide frequency range; Minimal losses and uneven conversion; High "decoupling" of channels; Large dynamic range of input signals; Harsh operating conditions Operating conditions Operating temperature range from minus 10 to 50 °C; Relative humidity up to 98% at a temperature of 25 ° C. Technical specifications Frequency range: • Microwave signal, GHz 37.5-78.33 • heterodyne, GHz 2.0-6.0 • IF, MHz 0-1000 Conversion losses *>, 30-40 dB by the 20th garm. The power level of the heterodyne, dBm 20-22 Connector type: • Microwave signal input P-waveguide with transitions to 5,2x2,6 and 3,6x1,8 mm • 1HR heterodyne input • IF output two woofer inputs
Produced in: Moscow