Magnetic stirrer PE-6110 with heating
Magnetic stirrer PE-6110 with heating
from 10 144 ₽
Technical specifications: - Maximum stirred volume - 1000 ml; - Armature rotation speed range – from 200 to 2000 rpm; - Heater surface temperature - 100 °C; - Maximum power consumption - 40 watts; - AC power supply - 50-60 Hz, 90-240 V - Overall size - 120x105x50; - Weight - 0.4 Transport data/dimensions/weight: 1 box, 200 x 130 x 70 mm., 0.8 kg.
EKROSKHIM
Saint Petersburg
Produced in: Saint Petersburg
Quenching water tank BZV – 10.12.15/0.8
Quenching water tank BZV – 10.12.15/0.8
Heating chamber power, kW 40 Supply voltage, V 380 ±15% Frequency, Hz 50 Number of phases 3 Maximum operating temperature, oS 80 The range of automatic temperature control, oS From 20 to 80 Stability of automatic temperature maintenance, oS ±6 Environment in the workspace Water, oil, polymer liquid. Warm-up time to maximum temperature, h 1,5 Heating control Digital controller Workspace dimensions: width,mm 1000 depth, mm 1200 height, mm 1500 Overall dimensions of the product: width (without control cabinet), mm 1800 depth, mm 2100 height, mm 2750 Weight, kg 700 Working hours, hours per day/days per week 24/5
Produced in: Tula
LB62 Laboratory bath
LB62 Laboratory bath
It is designed for thermostating samples in glasses, flasks and other laboratory utensils in cases where high accuracy of temperature maintenance is not required and good uniformity of the temperature field in the working volume is not needed. The operating temperature range is Current +5...+200 °C. Six workstations with a diameter of 110 mm with five steel O-rings. Stamped steel tub with a volume of 19 liters and a depth of 110 mm. Bath volume 19 l Overall dimensions 560x370x410 mm The open part of the bath is 500x290 mm Bath depth 110 mm Weight 13.5 kg Power consumption 2.5 kW
Produced in: Tomsk
Industrial drying cabinet SNOL-750
Industrial drying cabinet SNOL-750
from 1 267 696 ₽
The industrial drying cabinet is designed for drying, tempering, aging, thermal testing and other types of heat treatment of various materials in an air environment at temperatures up to 350 (optionally up to 500) ° C with forced air convection in stationary conditions.
Produced in: Tula
Automatic device for determining the flash point in a closed crucible TVZ-LAB-12
Automatic device for determining the flash point in a closed crucible TVZ-LAB-12
The TVZ-LAB-12 automatic apparatus is designed to determine the flash point in a closed crucible by the Pensky-Martens method in accordance with GOST R EN ISO 2719-2008, GOST R 54279-2010, GOST ISO 2719-2013, GOST 6356-75, GOST 9287-59, ISO 2719, ASTM D 93 (methods A, B and C). The device is designed taking into account all the requirements of the new GOST R EN ISO 2719-2008 for testing. Extensive software configuration options and a special design of the device ignition device allows you to obtain test results with high convergence in GSO even when using electric ignition according to GOST R EN ISO 2719-2008. Technical specifications: Flash temperature measurement range 0 ... 400°C Heating speed 0.5 ... 20°/min The range of setting the ignition period, 0.5 ... 10°C Igniting gas flame, electric spiral Flash sensor Thermocouple with low mass The rotation speed of the agitator is 30 ... 250 rpm Power consumption from AC 220V, no more than 600 watts Overall dimensions 465x340x390 mm The weight of the device is 15 kg
LOIP
Saint Petersburg
Produced in: Saint Petersburg
NTEGRA NANO IR
NTEGRA NANO IR
NT-MDT Spectrum Instruments is an INTEGRA Nano IR–scattering scanning near‑field optical microscope (s-NSOM) designed for the infrared spectral range. The AFM probe is located in the focus of an optical system that directs the IR laser radiation to the sample and collects the optical response. The collected radiation is sent to the Michelson interferometer for optical analysis. The far-field component of the collected signal is suppressed by synchronous detection. The INTEGRA Nano IR system allows detecting the amplitude and phase of the near-field signal. The spatial resolution of the resulting reflection and absorption contrasts is approximately 10 nm and is determined only by the size of the tip of the probe.
Produced in: Moscow, Zelenograd
Blue DPSS Laser 465 nm KLM-465-x
Blue DPSS Laser 465 nm KLM-465-x
DPSS lasers of the KLM-465/x series are optimal sources of coherent radiation for the construction of control and automation systems, alignment and marking devices, for scientific and medical purposes. Technical specifications Radiation output power: up to 15 W Radiation wavelength: 465 nm Output beam diameter: 1.5mm Divergence of the radiation beam: 1.3 mrad Instability of radiation power: 5% Type of modulation: TTL or analog Time to enter the mode: 15min Spectral line width: 0.1nm
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Circulation thermostat LT-417a
Circulation thermostat LT-417a
The LOIP LT-417a modification device consists of an immersion thermostat-circulator LOIP LT-400 and a working bath with a flat removable lid. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +200 with tap water cooling °C Tvods+5 ...+200 Accuracy of temperature maintenance, °C ± 0.01 The error of setting the set temperature, no more than, ° C ± 0.02 Heater power, W 2200 Pump: max. flow rate, l/min 6...12 pressure, 0.4 bar Bath volume, l 17 The working fluid is water, silicone oil. Open part of the bath / depth, Mm 360x296/150 Overall dimensions, mm 532x335x350 Weight, kg 14.4
LOIP
Saint Petersburg
Produced in: Saint Petersburg
DIGITAL MICROSCOPE
DIGITAL MICROSCOPE
The educational microscope is designed to observe transparent agents in transmitted light in a bright field, when studying natural sciences in schools of 2nd - 3rd stages and other educational institutions, as well as for various studies in laboratory practice.
Produced in: Crimea, Feodosia
Thermostat for Raid bombs LT-820
Thermostat for Raid bombs LT-820
Design features: Microprocessor-based PID controller; Multifunctional control knob; Minimum temperature gradient over the entire volume of the bath; Three places to plant Raid bombs; Hole for the control thermometer; Stainless steel bathtub with glass windows; Built-in cooling heat exchanger; Self-diagnosis system; A faucet for draining the working fluid. Technical specifications: Temperature range, °C - without external cooling - with tap water cooling (Current+10)...+100 (Tvods+5)...+100 Accuracy of temperature maintenance, °C ± 0.1 Number of places for Raid bombs 3 Power consumption from the mains 220 V, W 2200 Volume of working fluid, l 33 Working fluid - up to 80 °C - above 80 °C distilled water water-glycerin mixture Overall dimensions (WxDxH), mm 670x250x620 Weight of the device without liquid, kg 27
LOIP
Saint Petersburg
Produced in: Saint Petersburg
POZIS STANDARD ST 31 Tablet press
POZIS STANDARD ST 31 Tablet press
Productivity, thousand tab./hour 160 Number of stations 31 Max. pressing force, tn 10 Number of threads 2 Diameter of tablets, mm 6-25,4 Height of tablets, mm 1.5-9 Matrix filling depth, mm 18 Rotor material Rotor die plate: steel 40x13 Filling hopper capacity, l. 20(30) Stepless rotor speed change The change in the speed of rotation of the feeder is independent Supply voltage 380V, 50Hz Power consumption, kW/hour 4.18 Weight, kg 2200 Dimensions, mm 900x900x1800
POZIS
Зеленодольск
Produced in: Zelenodolsk, Tatarstan