Circulation thermostat LT-316a
Circulation thermostat LT-316a
Technical specifications: Temperature range: without external cooling, °C Current+10 ... +150 with tap water cooling °C Tvods+5 ...+150 Accuracy of temperature maintenance, °C ± 0.1 The error of setting the set temperature, no more than ° C ± 0.2 Heater power, W 2000 Pump: max. flow rate, l/min 8,0 pressure, 0.25 bar Bath volume, l 16 Working fluid water, water-glycerin mixtures, silicone oil The open part of the bath / depth, mm 190x296/200 Overall dimensions, mm 355x335x400 Weight, kg 12.8
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Water distiller AWD-7000F
Water distiller AWD-7000F
Distillers of the company "BELAKVILON" are designed to produce distilled water from tap water. Capacity 6.5 — 7 l/h Dimensions (mm), W x D x H 510 x 465 x 490 Heater 2 x 3.0 kW Cooling water consumption, l/h about 30 — 50 l/h Power supply 230 V ±10%, 50 Hz Switch Differential automatic Water level sensors Reed floats
Produced in: Belarus, Minsk
Rubidium frequency and time standards H1-1011/1
Rubidium frequency and time standards H1-1011/1
The modular construction principle makes it easy to adapt the devices to the specific requirements of the consumer. The standards are available in four versions – H1-1011, H1-1011/1, H1-1011/2 and H1-1011/3, which differ in metrological characteristics and a set of installed devices (modules). The built-in diagnostic system allows you to quickly determine the operability and condition of the main devices of the standards. On the front panel of the devices H1-1011 and H1-1011/2 there is an LCD display and a control panel, with which you can quickly receive information about the current parameters of the devices included in the devices and adjust the frequency of the output signals. The H1-1011 and H1-1011/2 standards can receive chronometric information from GLONASS and GPS satellite radio navigation systems and use it to synchronize the local time scale and automatically adjust the actual frequency value of the built-in highly stable rubidium frequency standard. The H1-1011 and H1-1011/2 standards include: rubidium frequency standard H1-1014; MPR-01 satellite radio navigation systems receiver module; amplifier module for highly stable sinusoidal signals (at the customer's choice): MUS-01 (3 independent outputs 10 MHz, connector type SR-50-73FV); MUS-02 (3 independent outputs of 5 MHz, connector type SR-50-73FV); MUS-03 (3 independent outputs of 1, 5 and 10 MHz, connector type SR-50-73FV); MUS-04 (6 independent outputs of 1, 5 and 10 MHz in any combination at the customer's choice, SMA connector type); MS synthesizer module with software (SMA connector type) instead of an amplifier module (at the customer's request). The scope of delivery (at the request of the customer) includes an antenna for the SRNS receiver as part of: antenna unit; mounting device; antenna cable (maximum length 60 m). The H1-1011/1 and H1-1011/3 standards include: the rubidium frequency standard H1-1013; two modules of amplifiers of highly stable sinusoidal signals (at the customer's choice): MUS-01 (3 independent outputs 10 MHz, connector type SR-50-73FV); MUS-02 (3 independent outputs of 5 MHz, connector type SR-50-73FV); MUS-03 (3 independent outputs of 1, 5 and 10 MHz, connector type SR-50-73FV); MUS-04 (6 independent outputs of 1, 5 and 10 MHz in any combination at the customer's choice, SMA connector type); MS synthesizer module with software (SMA connector type) instead of an amplifier module (at the customer's request).
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
Green Laser Module LG-D532-x-5 532nm line
Green Laser Module LG-D532-x-5 532nm line
from 11 026 ₽
The generators of the LG-D532-x-5 series are optimal sources of coherent radiation for the construction of control and automation systems, alignment and marking devices, for scientific and medical purposes.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Pure Air Generator GCHV-2.0-3.5
Pure Air Generator GCHV-2.0-3.5
from 200 400 ₽
The generators are designed to supply analytically clean air to flame ionization detectors and gas analyzers. They are available in two versions depending on performance and output pressure. Thanks to the presence of a system of catalytic purification of air from hydrocarbons, the generator can significantly improve the accuracy and sensitivity of chromatographic analyses. Technical specifications Air capacity reduced to normal conditions is not less than 2.0 l/min Outlet air pressure is 355 ± 5% kPa (3.5 ati) Output pressure stability at constant flow rate is not worse than ± 10 kPa The stability of the output pressure when the flow rate changes from 0.3 to the maximum value is not worse than ± 10 kPa Output concentration of hydrocarbons is not more than 0.1 ppm Water vapor concentration at 20°C and 100 kPa is no more than 10 ppm Ready time after switching on is no more than 30 min Power consumption is not more than 200 VA Overall dimensions of the generator (width x depth x height) are not more than 230x425x510 mm The mass of the generator is not more than 18 kg Working conditions: ambient temperature, °C from +10 to +35 relative humidity of the ambient air, % 80 power supply from a single-phase network: AC voltage, 220 ± 10% and frequency, Hz 50 ± 1
Produced in: Moscow
Mobile laboratory for 0.4-10 kV cable lines based on a trailer (ETL-10)
Mobile laboratory for 0.4-10 kV cable lines based on a trailer (ETL-10)
Laboratory for 0.4-10 kV cable lines based on a trailer (ETL-10) includes: 1. Test facility – Maximum rectified voltage up to 70 kV; – Maximum AC voltage of the industrial frequency of 50 Hz to 50 kV. 2. Burning facility – Maximum voltage up to 30 kV; – Maximum current up to 80 A; – Working hours are not limited; – Switching stages is carried out without breaking the arc at the time of switching; – The ability to start working from any stage of burning (when working with low–voltage cables); - Built-in afterburning. 3. High voltage pulse generator • – Output voltage 0...12 kV / 0...24 kV; • – The pulse energy at each stage is 3000 J; • – Built-in IDM for collaboration with the reflectometer. 5. High-voltage cable defects detector • – Determining the location and depth of the cable at a depth of up to 10 m; • – Tracing at a distance of up to 10 km; • – Search for live electrical cables; • – Search for places where the pipeline and cable intersect; • – Determining the places of damage to cable lines; • – Site surveys before excavation; • – Search for places of damage to the external insulation of the cable; • – GPS\GLONASS coordinates recording and mapping of found communications; • – Cable selection from the bundle; • – Search for the place of damage by acoustic method. 6. Autonomous air heater Planar – An autonomous air heater Planar with a capacity of 2 kW or an analog with a 7.5 l fuel tank.
Produced in: Kolomna, Moscow region
Biosafety cabinet BA-Safe 180
Biosafety cabinet BA-Safe 180
The Class II Type A2 biological safety cabinets are designed to reduce the risk of infection to the operator during work with dangerous or potentially dangerous microorganisms and to protect the specimen, is the result of the production of biological safety cabinets based on user feedback. Technical specifications Voltage, frequency, 230V ±10%/Hz Engine 1-phase 230 V, 50 Hz, speed 1150 rpm UV lamp TUV UV lamp, UV lamp timer, 6000 hours of operation Wavelength 254 nm Number of LEDs, pcs at least 380 Lighting power, 55 W Work area illumination at least 1500 lux, brightness adjustable, color of luminous flux 6000 K (cold white light) Internal dimension of the working area, at least 1830×504 mm Working height of front screen elevation, 200 mm Max. height of front screen elevation, 510 mm Frontal screen position alarm Audible position warning. Warning appears on display Outer dimension, mm 1968,5х766,2х1506,6 Height of base, mm 690
Produced in: Belarus, Minsk
Analytical scales VLA-220S-O
Analytical scales VLA-220S-O
from 359 990 ₽
Technical characteristics: NIP, G220 Discreteness, g0,0001 Calibration, self-calibration Diameter of the scale bowl, mm91 The smallest weighing limit, g0.01 The price of the verification division, mg1 Limits of permissible error of the scales during verification, ± mg, in weighing intervals:from 0.01g to 50g incl. ±0.5; sv. 50g to 200g incl. ±1.0; sv. 200g to 220g incl. ±1.5 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.3 in the entire range The time of setting the readings, s, no more than ~ 1.5 Overall dimensions of the scales, mm367x212x345 Weight of the scales, kg, no more than 7 The alignment weight is built 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Furnace for heating in a protective environment CHO (3)-6/11
Furnace for heating in a protective environment CHO (3)-6/11
from 1 420 750 ₽
Designation SNO(H)-6/11 Power, kW, no more than 8 Supply network voltage, V 380 Frequency, Hz 50
Produced in: Tula
LB41-Sh Laboratory bath
LB41-Sh Laboratory bath
It is intended for thermostating samples in glasses, flasks and other laboratory utensils in cases when high accuracy of temperature maintenance is not required and good uniformity of the temperature field in the working volume is not needed. The operating temperature range is Current +5...+200 °C. Four workstations with a diameter of 110 mm with five steel O-rings, tripods and feet with a clip. Stamped steel tub with a volume of 8 liters and a depth of 60 mm. Bath volume 8 l Overall dimensions 540x640x610 mm The open part of the bath is 325x290 mm Bath depth 60 mm Weight 10 kg Power consumption 2.5 kW
Produced in: Tomsk
pH-metrMARK® 902 / MARK® 902A
pH-metrMARK® 902 / MARK® 902A
Measurement of the activity of hydrogen ions (pH, pH25), EMF and temperature of aqueous media. Control of water-chemical regimes at thermal and nuclear power facilities. pH control of aqueous media in technological processes.Two channels | Freely programmable measurement ranges. The possibility of independent measurements at two points. Convenience and accuracy of measurement, minimum maintenance | Automatic thermal compensation. Calibration according to standard buffer solutions with their automatic determination. "Active" sensor unit | The digital communication channel of the sensor with the converter unit is up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. MODBUS RTU exchange protocol. Programmable setpoints with a "dry contact" type output. Durable aluminum housing IP65 | The device is reliably protected from dust and moisture. Graphic indicator with backlight | Convenient data presentation format and ease of settings
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
VOLTAMMETER PARMA VAF-A(M2)
VOLTAMMETER PARMA VAF-A(M2)
It will help relay protection and automation services, the chief power engineer of industrial enterprises and a wide range of specialists engaged in setting up, monitoring, diagnostics and operation of electrical installations to solve the following tasks: − control phase alternation − remove the voltage characteristics − measure phase shift angles and build vector diagrams of voltage and current − control the circuits in the SHPT − check the integrity of electrical conductors − carry out operational maintenance of relay protection circuits and power circuits of electrical installations − monitor the condition and diagnose DC circuits − carry out phasing when setting up differential protection and connecting current and voltage transformers, electric motors − check the correct connection of electricity meters − determine the harmonic composition of current and voltage (up to and including the 19th harmonic)
PARMA
Saint Petersburg
Produced in: Saint Petersburg