Metrology

525 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 23
    Areas of use
    Loading...
  • 194
    Item names
    Loading...
  • 53
    Manufacturer
    Loading...
  • 31
    Made in
    Loading...
  • 55
    Additional
    Loading...
View:
525 products
DOSIMETER‑RADIOMETER ISS‑AT1117M (STATIONARY‑PORTABLE DOSIMETRIC CONTROL POSTS)
DOSIMETER‑RADIOMETER ISS‑AT1117M (STATIONARY‑PORTABLE DOSIMETRIC CONTROL POSTS)
High sensitivity Audible, light and visual alarm of exceeding the set threshold levels The possibility of using both stationary and wearable versions Automatic recording and storage of at least 10,000 GPS-linked measurement results when using BOI4 The possibility of automatic data transfer to a remote server, as well as processing them in export application software when using BOI4
Produced in: Belarus, Minsk
Amplifier module MUS-04
Amplifier module MUS-04
The module uses connectors of the SMA type. At the request of the customer, any combination of output signals is possible. When installing two amplifier modules in the above devices, the total number of output signals increases to twelve.
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
Rubidium frequency standard H1-1014
Rubidium frequency standard H1-1014
The built-in time scale shaper provides a pulse signal of 1 c at the output of the device. Its small dimensions, weight, power consumption, and operating time allow it to be widely used as an embedded source of high-stability signals in frequency measuring devices and complexes, telecommunications systems, navigation and communication systems. It includes a frequency binding module based on a pulse signal of 1 s from an external time scale or from a SRNS GLONASS/GPS receiver and a tunable frequency synthesizer with the ability to adjust the frequency via the RS-232 interface. The built-in binding module allows the device to be used when operating in automatic correction mode as a source of a highly stable signal with a frequency error of ± 5 · 10-12 per day.
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
Mobile laboratory of measuring equipment PLIT-A2-4/1M
Mobile laboratory of measuring equipment PLIT-A2-4/1M
The complex is equipped with air conditioning, heating and ventilation systems to create and maintain a preset temperature level (20 ...25) ° C in the van body, at an outdoor temperature from minus 40 ° C to 40 ° C. PLIT-A2-4/1M is equipped with a removable diesel electric unit with a capacity of 16 kW, which ensures the functioning of all systems in autonomous mode. A set of functionally related working standards, special equipment and automation tools allows you to implement comprehensive metrological maintenance of measuring instruments at workplaces
Produced in: Moscow
EVRAZCOMB – 3 in 1
EVRAZCOMB – 3 in 1
Purpose: Measurement of temperature, oxygen activity and sampling of molten metal Scope of application: Oxygen converters, electric arc furnaces, induction furnaces, casting buckets Measuring range: from 1 to 2000 ppm O - metal oxidation from 1400 to 1800 °C - metal temperature from 0.010 to 0.200% - carbon content Accuracy: 0 + 3 °C at 1554 °C; (from 5 to 10) mV (depending on the oxygen activity level) The shape of the selected metal shape: Circle: thickness 12 mm Oval: thickness 12 mm Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium Measurement time: 8 sec Tube Length: from 100 to 2500 mm (other length is possible on request) Slag Cap: Steel, Aluminum, Copper, cardboard Type of NSH: B, S, R
Produced in: Lipetsk
SPECTROMETER MCG‑AT1321
SPECTROMETER MCG‑AT1321
- Search and detection of gamma radiation sources with identification of radionuclide composition - Measurement of the ambient dose equivalent of gamma radiation The combination of compactness and high sensitivity The possibility to analyze the spectrum and identify radionuclides without using a PC A built-in GPS module Audiable, light and vibration alarms
Produced in: Belarus, Minsk
Signal generator of a special form G6-49
Signal generator of a special form G6-49
General characteristics: USB 2.0 interface, SCPI support Power supply ~ 230 V, 35 V*A Operating temperature range from minus 10 C to + 40 C Dimensions; weight 325×270×125× mm; 4 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Sorption-filtering analytical filters AFA-SI-20
Sorption-filtering analytical filters AFA-SI-20
Sorption analytical filters AFA-SI are used for simultaneous capture and determination of samples of aerosols and vapors of radioactive iodine, followed by measurement of the delayed sediment by radiometric devices.
Doza
Zelenograd
Produced in: Moscow
eLajt03 Luxmeter
eLajt03 Luxmeter
from 26 900 ₽
Certified luxmeter sensor with pulse meter and brightness meter functions for connection to a PC (via USB), BOI-01, BOI-02 and Ecofizika units.
Eco-E
Москва
Produced in: Moscow
ASKRO: Automated radiation monitoring system
ASKRO: Automated radiation monitoring system
The installations are designed for continuous monitoring of the radiation situation at specified points of radiation objects with data transmission via VHF radio frequency channel and/or GSM/GPRS network. Purpose: radiation monitoring of industrial sites of nuclear power plants and other radiation facilities (RCP); radiation monitoring of the environment of sanitary protection zones and observation zones (RCOS); creation of an automated system for monitoring the radiation situation (ASKRO) of territories, sanitary protection zones (SPZ) and monitoring zones (ZN) of radiation-hazardous objects; creation of situational crisis centers (SCC) of enterprises and regions.
Doza
Zelenograd
Produced in: Moscow