Central Heating Unit Medium (CHU-M) Kit
Central Heating Unit Medium (CHU-M) Kit
The kit is designed to control the temperature and pressure at the points of water sampling of hot water and HVAC systems, archiving the measured results for the purpose of their further documentation and analysis. The TSTP-M kit allows you to record changes in temperature and pressure directly at the points of water intake of hot water and HVAC, for a long period. With the subsequent transfer of data recorded in the device's memory to a computer, for printing a report, graph, etc. Features of the CHU-M kit The CHU-M kit allows you to control the pressure and temperature at the hot water and HVAC disassembly points. The kit consists of a four-channel meter recorder, which allows you to store 15,000 values in memory, for each channel with an interval of 5 seconds. up to several hours, which allows you to take measurements and store data for up to 1 year.
Produced in: Kolomna, Moscow region
VE-26NP Eddy current structuroscope
VE-26NP Eddy current structuroscope
from 175 000 ₽
Distinctive features: The built-in thermometer allows you to take into account the influence of ambient temperature and improve the measurement accuracy. The built-in memory stores 4096 electrical conductivity measurement results for subsequent transfer to a PC. Specifications: Measuring range of the absolute value of specific electrical conductivity, MSm/m from 5 to 60
Measuring range of increments of electrical conductivity, MS/m from -9.99 to +9.99 Limit of permissible basic relative measurement error, % no more than 2 Permissible gap between the transducer and the surface of the controlled product, mm, no more than 0.25 Digital display of measurement results Power supply from RRZ type battery, V 9 Power consumption, mW, no more than 40 Operating temperature range, °C 5...40 Dimensions, mm 57*84*30 Weight, g 270±20
Produced in: Moscow
INSULATION PARAMETER METER PARMA TENSOR-2
INSULATION PARAMETER METER PARMA TENSOR-2
PARMA TENSOR-2 (AC bridge) is designed for automatic measurements of: · capacitance and tangent of the dielectric loss angle of high-voltage insulation of capacitors, inputs, transformers using an external high-voltage capacitor, both in laboratory and in the "field" conditions · effective values of the first harmonic of the current and voltage of the industrial frequency · the angle of phase shift between the signals supplied to the inputs of the device · network frequencies * Measurements can be carried out according to the "straight" and "inverse" (inverted) scheme. * Allocates the vector of the influence current, which makes it possible to dispense with the phase regulator of the test voltage source or devices for compensating the influence current.
PARMA
Saint Petersburg
Produced in: Saint Petersburg
Central Heating Unit N (CHU-N) Kit
Central Heating Unit N (CHU-N) Kit
It is designed to control the excess pressure during the crimping of pipelines before putting them into operation, as well as during scheduled system health checks. The devices are registered in the State Register of Measuring Instruments for No. 30414-11, No. 43646-10 and are approved for use in the Russian Federation. Features of the CHU-N kit Carrying out pressure testing before the start of commissioning allows you to identify possible defects in seams and pipes, ensuring their tightness and reliability of insulation. The kit is designed to work in the field in order to record and archive the measured results to identify possible defects. The CHU-M kit is a portable complex with autonomous power supply.
Produced in: Kolomna, Moscow region
DOSIMETER DKS‑AT5350/1
DOSIMETER DKS‑AT5350/1
A high-precision dosimeter with extensive functionality: measurement of DC power, electric charge, charge by numerical integration of current, kerma and kerma power in the air, kerma by numerical integration of kerma power and other radiological quantities. Composition of the dosimeter: - Electrometric measuring unit (electrometer) - PTW-Freiburg ionization chambers (Germany) to choose from: TM23342 Flat-parallel X-ray (volume 0.02 cm3) TM31010 Cylindrical (volume 0.125 cm3) TM30010 Thimble (volume 0.6 cm3) TM23361 Cylindrical (volume 30 cm3) TM32002 Spherical (volume 1000 cm3)
Produced in: Belarus, Minsk
VE-meter. Modification of "AT-004" and "50Hz" with control unit "NTM-Terminal"
VE-meter. Modification of "AT-004" and "50Hz" with control unit "NTM-Terminal"
from 66 500 ₽
The three-component electric and magnetic field parameter meter is designed to monitor electromagnetic safety standards for special assessment of working conditions, production control and comprehensive sanitary and hygienic inspections of facilities. The meter is equipped with isotropic EMF (non-directional reception) sensors.
Produced in: Moscow
X‑RAY CALIBRATION INSTALLATIONS UPR‑AT300, UPR‑AT300/1, UPR-AT300/2
X‑RAY CALIBRATION INSTALLATIONS UPR‑AT300, UPR‑AT300/1, UPR-AT300/2
Storage and transfer of kerma units in the air, ambient, individual and directional dose equivalents and their X-ray radiation capacities to working standards and measuring instruments. ▪ The use of highly stable ISOVOLT X-ray machines with metal-ceramic tubes ▪ Field shaper with radiation qualities according to GOST 8.087, ISO 4037, IEC 61267, etc. ▪ Replaceable discs with 11 filter slots; 3 replaceable diaphragms ▪ Additional filters up to 50 mm thick ▪ A protective flap made of tungsten with beam attenuation of more than 1000 times and a response time of less than 0.1 s ▪ A camera monitor and an electrometric unit provide monitoring of the presence and stability of the radiation output ▪ A positioning system in the radiation beam along three axes ▪ A laser detector centering devices ▪ A video surveillance system of indications ▪ Alarm and blocking systems, radiation monitoring ▪ A control system using operator panels and PC
Produced in: Belarus, Minsk
measuring air-thermal installation  ASESH-8-2
measuring air-thermal installation ASESH-8-2
1 supp.
Implements a thermogravimetric (air-thermal) method for determining the mass fraction of moisture, based on measuring the mass of the sample of the analyzed substance before and after drying, followed by calculating the values of the mass fraction of moisture. Air-thermal measuring installations ASESH-8 are registered in the State Register of Measuring Instruments under No. 58526-14, have a certificate of approval of the type of measuring instruments OC.C.31.005 And No. 56847.The installations undergo initial verification and have the appropriate certificate. General characteristics: - The presence of two independent drying chambers. - Possibility of simultaneous determination of humidity of 12 samples: Each drying chamber of the installation consists of 6 independent cells. You can put 2 buckets in each cell. Total capacity of the ASES Installation-8-2 – 24 bucs. - Convenient access to the cells of the drying chamber: On the front side of the cabinet there are four doors for access to the cells. - Natural ventilation: The absence of rotating elements ensures absolute noiselessness of operation and a long service life. - Built-in timer: The ASESH-8-2 installation has 4 timers, by means of which the end of the drying process is monitored in each section with the output of an audible signal and a light indication. - The output to the operating mode is 30 minutes: The power of air-thermal installations is 1200 watts. When entering the operating mode, the power consumption is the same as that of similar cabinets with low power. SCOPE OF DELIVERY : 1. Installation of ASESH-8-2 2. AO-3 cooler 3. Auxiliary accessories 4. Air-heat control unit: 5. Interface unit for connecting a personal computer with a scale (available on request); 6. software for processing and archiving measurements of humidity determination data; The program allows you to: Set the operating temperature in the chambers via a personal computer Set the necessary parameters of the sample drying process according to the selected method Display all current processes (predrying, drying, cooling) and parameters (temperature, time) during the tests. To monitor the process by means of an electronic timer with the output of an audible signal. Record all weighing results. Perform humidity calculations in accordance with standardized methods. To calculate the humidity with pre-drying, the program uses formulas that allow you to get an accurate result. Archive and print test results. According to the test results of FSUE "UNIIM", it is recommended to use a laboratory mill of the BLIZZARD series for sample preparation. SCOPE OF APPLICATION: 1. Crop production, agriculture and forestry. 2. Products of meat, dairy, fish, flour-milling, feed and microbiological industries. 3. Food industry products. 4. Cellulose, paper, cardboard and products made from them. 5. Medicines, chemical and pharmaceutical products and medical products. 6. Building materials. 7. Products of the logging and sawmilling and woodworking industry. 8. Ground, soils, mineral fertilizers. Technical specifications: The measurement range of the mass fraction of moisture, % from 0.5 to 80 Operating temperature range, °C from 45 to 160 The error of setting and maintaining the temperature in the working area, ° C, not more than 2.0 Limits of permissible absolute error, % ± 0.5 Power consumption, V• A, not more than 1200 Overall dimensions, mm 240 × 260 × 640 Overall dimensions of the cell, mm 75 x 40 x 165 (depth) Weight, kg 28.4
GK EKAN
Saint Petersburg
Produced in: Saint Petersburg
PULSE RADIATION MONITORING SYSTEM
PULSE RADIATION MONITORING SYSTEM
Logging data on dose rate levels and exceeding threshold levels Software that allows you to display on a PC monitor the current radiation situation at a controlled facility Backup power supply High radiation resistance – at least 50,000 Sv for UDKG-37 Failure diagnostics The possibility of using the system for dosimetric monitoring of both pulsed and continuous gamma radiation The possibility of using the DKS-AT1123 dosimeter autonomously as a wearable device
Produced in: Belarus, Minsk