Technical laboratory scales VLTE-2100T
Technical laboratory scales VLTE-2100T
from 27 490 ₽
Technical characteristics: NIP, G2100 Discreteness, g0,1 External calibration The size of the scale bowl / platform, mm175x145 The smallest weighing limit, g5 The limits of permissible error during primary verification, mgot 0.5g to 500 g incl. ±50; sv. 500g to 2000g incl. ±100; sv. 2000g to 2100g incl. ±150 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high Weight adjustment 2KGF2* The time of setting the readings, s, no more than ~ 1 - 1.5 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLTE-2100/5100S
Laboratory scales VLTE-2100/5100S
from 77 490 ₽
Technical characteristics: NIP, G2100/5100 Discreteness, g0,01/0,1 Calibration, self-calibration The size of the scale bowl / platform, mm175x145 The smallest weighing limit, g0.5/5.0 The price of the verification scale division, mg100/1000 Limits of permissible error during initial verification, mgot 0.5g to 500g incl. ±50/±500; sv. 500g to 2000g incl. ±100/±500; sv. 2000g to 2100g incl. ±150/±500; sv. 2100g to 5000g incl. ±500; sv. 5000g to 5100g incl. ±1000 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The weight adjustment is built-in The time of setting the readings, s, no more than ~3 /~2 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Voltmeter demonstration universal VDU-1
Voltmeter demonstration universal VDU-1
Designed to measure electrical quantities (DC voltage and strength, AC voltage and strength, DC electrical resistance) during demonstration work in physics. The device performs the function of a demonstration multimeter. Technical specifications: Measurement of DC voltage from 0 to 100 V measurement error, not more than 1.0 % Measurement of AC voltage from 0 to 60 V measurement error, not more than 1.0% measurement of DC power from 0.01 to 200 measurement error, not more than 1.0 % Measurement of AC power from 0.01 to 200 mA measurement error, not more than 1.0 % Measurement of DC resistance from 1 ohm to 2 mOhm measurement error, no more than 1.0% power supply from the USB port of the computer power consumption, no more than 0.6 V × A weight, no more than 0.3 kg overall dimensions 172x25x77 mm
MNIPI
Minsk
Produced in: Belarus, Minsk
Technical laboratory scales VLTE-410T
Technical laboratory scales VLTE-410T
from 34 990 ₽
Technical characteristics: NIP, G410 Discreteness, g0,01 External calibration The size of the scale bowl / platform, mm116 The smallest weighing limit, g0.2 The limits of the permissible error during the initial verification, mgot 0.2g to 50 g incl. ±5; sv. 50g to 200g incl. ±10; sv. 200g to 410g incl. ±15 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high Weight adjustment 200gF2* The time of setting the readings, s, no more than ~ 1 - 1.5 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
RUNWAY-12 platform scales
RUNWAY-12 platform scales
from 69 990 ₽
Technical characteristics: NIP, kg12 Discreteness, g0.5/(0.2)* External calibration The size of the weighing platform, mm350x320 The smallest weighing limit, g50 Accuracy class according to GOST OIML R 76-1-2011II is high Limits of error allowed during initial verification, goth 50g to 5 kg incl. ±0.5; sv.5kg to 12 kg ± 1.0 Dust and moisture protection (IP)54/65 (on request) The setting time, s, no more than ~ 1 - 1.5 Weight adjustment 5kgF2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Wavelegth dispersive sulfur-in-oil analyzer ASV-2
Wavelegth dispersive sulfur-in-oil analyzer ASV-2
The sulfur analyzer ASV-2 is designed to measure the mass fraction of sulfur in gasoline (unleaded), diesel fuel, oil, kerosene, oil residues, lubricating oil bases, hydraulic oils, jet fuels, crude oil and other distillate oil products. The ASV-2 analyzer allows to perform the functions of determining sulfur both in the vacuum mode of the measuring chamber and in the helium purge mode. For this purpose the device is equipped with a set of accessories for connection of the analyzer to the helium post.
Burevestnik
Kolomyagi
Produced in: Saint Petersburg
Technical laboratory scales VLTE-310P-V
Technical laboratory scales VLTE-310P-V
from 47 490 ₽
Technical specifications: NIP, g310 Discreteness, g0,005/(0.002)* Internal calibration The size of the scale bowl / platform, mm116 The smallest weighing limit, g0,1 The limits of permissible error during initial verification, mgot 0.1g to 50 g incl. ±5; sv. 50g to 200g incl. ±10; sv. 200g to 310g incl. ±15 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II high Weight adjustment is built-in The time of setting the readings, s, no more than ~ 1 - 1.5 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Digital oscilloscope C8-39
Digital oscilloscope C8-39
It is designed to study periodic signals in the frequency band 0-50 MHz and single electrical signals by registering them in digital memory with a sampling frequency of up to 50 MHz, observing their shape on a liquid crystal display (LCD), measuring the amplitude and time parameters of the signal under study. Technical specifications: Vertical deviation :2 Number of channels 0-50 MHz Rise time of PH ≤ 7.0 ns Input impedance 1 ± 0.03 mOhm, 25 pF Deviation coefficients of 5 mV/div - 2 V/div (step 1-2-5) The maximum input voltage is 100 V With a divider of 1:10 250 V The error of amplitude measurements is a≤ 2 % 5 mV...2 V; 10 ns...2 s/del. ADC: 2 channels, 50 MHz, 8 bits Equivalent sampling rate of 2.5 GHz Marker measurements U: ±2.5%, T: ±1.5% Pre-launch 8 screens, post-launch 150 screens Simultaneous observation of 2 signals Cursor measurements DU and DT Averaging modes and automatic DU and DT measurements LCD screen - 320x240 dots (monochrome) RS 232C interface Dimensions, weight 176x280x80 mm, 3 kg Power supply: +12V, 230B
MNIPI
Minsk
Produced in: Belarus, Minsk
Technical laboratory scales VLTE-2100P-V
Technical laboratory scales VLTE-2100P-V
from 42 490 ₽
Technical characteristics: NIP, g2100 Discreteness, g0.05/(0.02)* Internal calibration The size of the scale bowl / platform, mm175 x 145 The smallest weighing limit, g2.5 Limits of permissible error during primary verification, mgot 2.5g to 500g incl. ±50; sv. 500g to 2000g incl. ±100; sv. 2000g to 2100g incl. ±150 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The weight adjustment is built-in The time of setting the readings, s, no more than ~ 1 - 1.5 5-year warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
A set of measures of electrical resistance H2-2
A set of measures of electrical resistance H2-2
Designed for storing and transmitting the size of a resistance unit, as well as for checking and calibration of working resistance measures and complex resistance meters with a four-pair or five-clamp connection scheme in the frequency range from DC to 10 MHz. Description: Each of the resistance measures H2-2 is a precision resistor, in series and in parallel to which fitting resistors are connected, placed in an aluminum housing. The measures have a four-pole connection scheme. Four BNC type connectors (plugs) are located on the wall of the housing. The distance between the connectors is 22 mm. In measures of 100 kOhm and 1 mOhm, it is possible to adjust the value of the time constant of the measure using a tuning capacitor.
MNIPI
Minsk
Produced in: Belarus, Minsk
RUNWAY-52 platform scales
RUNWAY-52 platform scales
from 67 490 ₽
Technical characteristics: NIP, KG52 Discreteness, g5/(2)* External calibration The size of the weighing platform, mm350x320 The smallest weighing limit, g500 Accuracy class according to GOST OIML R 76-1-2011II is high Limits of error allowed during initial verification, goth 500g to 50 kg incl. ±5.0; sv.50kg to 52kg incl. ±10.0 Dust and moisture protection (IP)54/65 (on request) The setting time, s, no more than ~ 1 - 1.5 Weight adjustment 20kg F2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
IPPP-1 Semiconductor Device Parameter Meters
IPPP-1 Semiconductor Device Parameter Meters
Technical specifications: 4-channel automated system for measuring the parameters of semiconductors (including test structures on plates) Study of the VAC of 2, 3, 4-pole Parameters of each channel Source/meter:- U: ±2 V, ±30 V (200 mA), ±120 V (±10 mA), I: ±20, ±200 nA, ±2, ±20, ±200 Ma, ±2, ±10mA, (±120V), ±20, ±200 mA (±30V) Source and meter error U, I ± 0.5% Sensitivity of the U/I meter: 10 mv/ 0.1 pA Graphs, tables, texts, databases RS-232C interface, computer software Dimensions, weight: 450x266x444 mm, 23 kg Power supply: ~220V, 120 VA
MNIPI
Minsk
Produced in: Belarus, Minsk