Laboratory scales VLE-223S
Laboratory scales VLE-223S
from 107 490 ₽
Technical characteristics: NIP, G220 Discreteness, g0,001 Calibration,self-calibration The size of the scale bowl / platform, mm108x105 The smallest weighing limit, g0.02 The price of the calibration division, mg10 The limits of the permissible error during the initial verification, mgot 0.02g to 50 g incl. ±5; sv. 50g to 200g incl. ±10; sv. 200g to 220g incl. ±15 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The actual typical error limits of the scales, mg * ± 3 in the entire range The adjustment weight is built-in The time of setting the readings, s, no more than ~ 1.5 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Oscilloscope S1-167/2
Oscilloscope S1-167/2
Designed for the study of periodic electrical signals by visual observation and measurement of their amplitude and time parameters on the scale of the CRT screen in the frequency band 0 - 25 MHz with a built-in multimeter measuring voltage and DC power, the average square value of voltage and AC power, DC electrical resistance. Technical specifications: Vertical deviation Number of channels 2 Bandwidth 0-25 MHz Deviation coefficients 2 mV/div-10 V/div (step 1-2-5) Installation error ± 3% Rise time of PH <= 14 nsec Input impedance 1 mOhm/23 pF, with divider 1:10-10 mOhm/12 pF with open input <=110 V with closed input <=110 V with divider 1:10 <= 250 V range U post. U AC: 1 mV–500 V Error 0.1% (U post); 0.3% -1% (U perem. 40 Hz–100 kHz) Range I post., I AC.: 1 mA–2 A Error: 0.25% (I post.); 0.5% (I perem. 40 Hz–5 kHz) R Range: 1 Ohm–1 mOhm Error R: 0.2% 3.5-digit indicator Automatic selection of limits.
MNIPI
Minsk
Produced in: Belarus, Minsk
Educational laboratory complex KUL-1
Educational laboratory complex KUL-1
It is intended for use in higher and secondary educational institutions during laboratory workshops on training specialists in engineering and technical specialties and natural science disciplines. Technical specifications: Upost.- 0.1 mV - 500 V; Uperem.- 1 mV-300 V (40 Hz-20 kHz) Ippost. - 0.1 mkA- 2 A; Iperem. - 1.0 mkA - 2 A (40 Hz-1 kHz) Rpost. - 0.1 Ohm – 20 mOhm Generation of triangles, pilobr., "meander", sinusoid. signal in the frequency range 0.1 Hz – 1 MHz Frequency measurement in the range of 0.1 Hz – 1 MHz The form of the measured signals is sine, pulse Constant voltage: at a current of 1 A - + 5 V at a current of 0.5 A for each channel - ± 12 V Adjustable Uppost. at a current of up to 1 A - 0 – 30 V Dimensions - 170x340x380 mm Power supply – 230 V, 50 Hz, 200 VA - max. Weight – 8.0 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Laboratory scales VLTE-3100
Laboratory scales VLTE-3100
from 67 490 ₽
Technical specifications: NIP, g3100 Discreteness, g0,01 External calibration The size of the scale bowl / platform, mm175x145 The smallest weighing limit, g0.5 The price of the verification scale division, mg100 Limits of permissible error during primary verification, mgot 0.5g to 500g incl. ±50; sv. 500g to 2000g incl. ±100; sv. 2000g to 3100g incl. ±150 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The time of setting the readings, s, no more than ~3 Weight adjustment 2kgF2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
EPR spectrometer CMS8400 NEO
EPR spectrometer CMS8400 NEO
The CMS8400 NEO is a compact electron paramagnetic resonance spectrometer designed for routine research in physics, chemistry, biology and related scientific fields for direct detection of free radicals and paramagnetic materials. The CMS8400 NEO can be used in both laboratory and industrial settings in the mode of on-line measurements, embedded in technological processes, thus providing control of parameters and reactions in the production process. Additional accessories and adapted software can make the spectrometer an analytical tool and allow to implement new complex applications in medicine, petrochemistry, brewing, sanitary and hygienic control, as well as in other industries.
Produced in: Belarus
Flame Photometric(FD)
Flame Photometric(FD)
Selective detector for phosphorus and organosulphide compounds. It is used mainly for the analysis of sulfur-containing substances (hydrogen sulfide, mercaptans, thiophenes, etc.). The sensitivity for sulfur reaches 0.1. ppm. In addition, PFD has sufficient sensitivity and selectivity to compounds containing nitrogen, boron, tin, chromium, selenium, germanium, as well as CO, POPS, MgOx, $02, Ma, NOT C52. The selectivity of 5-containing compounds to hydrocarbons is 105. Technical characteristic: 8,0*10-13 g5/s by sulfur 1.0*10`13 g/s for phosphorus
Produced in: Yoshkar-Ola, Mari El
Flame Ionization (PID) for chromatograph
Flame Ionization (PID) for chromatograph
The most common, universal detector that is suitable for the analysis of a wide range of organic compounds. The sensitivity depends mainly on the number of carbon atoms. In combination with a methanator, it allows the analysis of carbon oxides at the level of 0.1 Rt. The level of fluctuation noise is up to 50 MV, the maximum signal is up to 2500 V. Technical characteristic: 1.2*10712 gs/s for hydrocarbons
Produced in: Yoshkar-Ola, Mari El
Laboratory scales VLTE-2100/5100S
Laboratory scales VLTE-2100/5100S
from 67 490 ₽
Technical characteristics: NIP, G2100/5100 Discreteness, g0,01/0,1 Calibration, self-calibration The size of the scale bowl / platform, mm175x145 The smallest weighing limit, g0.5/5.0 The price of the verification scale division, mg100/1000 Limits of permissible error during initial verification, mgot 0.5g to 500g incl. ±50/±500; sv. 500g to 2000g incl. ±100/±500; sv. 2000g to 2100g incl. ±150/±500; sv. 2100g to 5000g incl. ±500; sv. 5000g to 5100g incl. ±1000 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The weight adjustment is built-in The time of setting the readings, s, no more than ~3 /~2 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Mercury Monitor type RA-915AM for Natural Gas Analysis
Mercury Monitor type RA-915AM for Natural Gas Analysis
Technical specifications: Absorption coefficient of mercury vapor by the built-in sorption filter, %, not less than 98 Volume flow rate of the analyzed gas at the monitor inlet, dm3/min, not less than 4 Monitor power supply from AC mains: voltage, V frequency, Hz 220 ± 22 50 ± 1 Power consumption, In × A, not more than 150 Overall dimensions (LXC), mm, no more 665x482x222 Weight, kg, not more than 25 Operating conditions: - ambient temperature, °C from 10 to 35 - relative humidity (at 25 °C), %, not more than 80 - atmospheric pressure, kPa from 84 to 106.7 - relative humidity of the analyzed gas (at 20 °C), %, not more than 99 Average time to failure, h 12000 Average service life, 5 years
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Laboratory mercury analyzer "RA-915Lab"
Laboratory mercury analyzer "RA-915Lab"
Technical specifications: Measuring range 0.5–500 ng Sample dispenser capacity 5000 mg / 2800 ml Analysis time 1-5 min Operating temperature range with software control 50-950 °C with software control The capacity of the autosampler is 45 samples Power supply 220 ± 22 V, 50 ± 1 Hz Dimensions (LxWxH), no more: with autosampler without autosampler 450x840x460 mm 450x490x460 mm Weight, no more: with autosampler without autosampler 57 kg 40 kg
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Voltmeters B7-91, B7-91/1
Voltmeters B7-91, B7-91/1
Technical specifications: DC voltage , Measuring range, 10 MV - 1000 V Measurement error, ± 0.03% AC voltage , Measuring range, 1 mV - 750 V Measurement error, ± 0.4% Frequency range, 20 Hz- 100 kHz Direct current , Measuring range, 1 mkA - 2 A (B7-91/1) Measuring range, 1 mkA - 20 A (B7-91) Measurement error, ± 0.03%
MNIPI
Minsk
Produced in: Belarus, Minsk
Analytical scales VLA-220S-O
Analytical scales VLA-220S-O
from 269 990 ₽
Technical characteristics: NIP, G220 Discreteness, g0,0001 Calibration, self-calibration Diameter of the scale bowl, mm91 The smallest weighing limit, g0.01 The price of the verification division, mg1 Limits of permissible error of the scales during verification, ± mg, in weighing intervals:from 0.01g to 50g incl. ±0.5; sv. 50g to 200g incl. ±1.0; sv. 200g to 220g incl. ±1.5 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.3 in the entire range The time of setting the readings, s, no more than ~ 1.5 Overall dimensions of the scales, mm367x212x345 Weight of the scales, kg, no more than 7 The alignment weight is built 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg