Threshold detector of radioactive aerosols IRAA–01D
Threshold detector of radioactive aerosols IRAA–01D
Appointment: continuous measurement of the volumetric activity of radioactive aerosols caused by technogenic alpha-emitting nuclides; sound feed/light signaling in case the measured values of volumetric activity exceed the established threshold levels. Features: stationary placement in places where the air parameters of the working area are monitored; connection to a BN-01 type pump unit or other external sampling device; USB service interface for diagnostics, configuration, verification.
Doza
Zelenograd
Produced in: Moscow
Installation for measuring the volumetric activity of radioactive gases in the air UDG-1B
Installation for measuring the volumetric activity of radioactive gases in the air UDG-1B
Purpose: measurement of the volumetric activity of beta-emitting gases (argon, krypton, xenon). Properties: built-in air flow indicator; compensation for the effects of external gamma background; communication interfaces RS-232, RS-485, Ethernet; sound and light alarm of exceeding the set thresholds; working with your own pumping unit or with an external sampling line; setup using a portable computer; periodic verification without disassembly using an exemplary source; availability of discrete output signal of the device; the possibility of connecting an external emergency alarm unit BAS.
Doza
Zelenograd
Produced in: Moscow
Dosimeter-radiometer ISS-15D "Bullfinch"
Dosimeter-radiometer ISS-15D "Bullfinch"
Dosimeter is a gamma-beta radiation radiometer for working in "dirty" conditions. Allows you to switch modes and take measurements in conditions of radioactive contamination. Measurement of the beta radiation flux density is carried out with automatic subtraction of the gamma radiation background. Purpose: measurement of the ambient dose equivalent of H*(10) gamma radiation; measurement of ambient dose equivalent of H*(10) gamma radiation; measurement of beta particle flux density; estimation of the counting rate with combined measurements of gamma and beta radiation.
Doza
Zelenograd
Produced in: Moscow
Dosimeter-radiometer DKS-96 (with detection unit BDKS-96b)
Dosimeter-radiometer DKS-96 (with detection unit BDKS-96b)
It is recommended for workplace monitoring when working with medical and industrial X-ray machines and installations, X-ray flaw detectors, X-ray equipment for baggage inspection.
Doza
Zelenograd
Produced in: Moscow
Gamma radiation detector threshold stationary SRPS-05D
Gamma radiation detector threshold stationary SRPS-05D
A simple and reliable device for monitoring the radiation situation in rooms where work is carried out with radioactive sources (substances, medications, installations). If the set threshold value of the dose rate is exceeded, the device gives a sound and light signal, controls external devices (for example, door locking devices). Purpose: measurement of the ambient dose equivalent of gamma radiation (MAED); sound and light alarm about exceeding the set threshold; activation of external signaling or actuating devices.
Doza
Zelenograd
Produced in: Moscow
Installation of pollution control of personnel RZBA-07D
Installation of pollution control of personnel RZBA-07D
Purpose: measuring the level of contamination of hands, feet (shoes) and clothing of personnel with beta-active substances and signaling when exceeding permissible levels monitoring the level of contamination with alpha-emitting radionuclides monitoring the contamination of personnel at nuclear power plants, nuclear fuel cycle enterprises (NFC), radiological laboratories, other enterprises and institutions using radioactive substances.
Doza
Zelenograd
Produced in: Moscow
Multifunctional UKRV-2 air flowmeter
Multifunctional UKRV-2 air flowmeter
Purpose: measurement of the volume of air pumped through the analytical filter; measurement of volumetric air flow through an analytical filter. Features: output of information to the LCD indicator; automatic and manual control of an external actuator (valve, crane); obtaining information about the analytical filter used using a barcode reader; transmission of data on the state of the device, the measured volume flow and the pumped volume of air to communication channels; providing access to information via the RS-485 interface; work both independently and as part of radiation monitoring systems
Doza
Zelenograd
Produced in: Moscow
Generator of cardiac-like signals GKS-2D
Generator of cardiac-like signals GKS-2D
Checking the performance of cardiographs, cardiac monitors and cardiac units of intensive care monitors; checking the general functionality and imitation of the patient (when checking stress systems, a cardioid signal is formed); checking the amplitude of the signal recording (a U-shaped signal is formed).
Doza
Zelenograd
Produced in: Moscow
Portable flow meter-sampler of gas-aerosol mixtures PVP-06
Portable flow meter-sampler of gas-aerosol mixtures PVP-06
Purpose measurement and control of the pumping speed and the total volume of the aerosol mixture pumped through the filters installed on the product during sampling in order to determine the content of aerosol pollutants in the air
Doza
Zelenograd
Produced in: Moscow
Installation of control of surface radioactive contamination of personnel RZBA-08D
Installation of control of surface radioactive contamination of personnel RZBA-08D
Installation for monitoring radioactive contamination of hands, feet (shoes) and clothing of personnel with beta-, gamma- and alpha-active nuclides, convenient and intuitive interface, various versions. Purpose: monitoring the level of contamination of hands, feet (shoes) and clothing of personnel with beta-, gamma- and alpha-emitting radionuclides and signaling when exceeding permissible levels; measurement of beta and alpha radiation flux density from the surface of the hands, feet (shoes) and clothing of personnel; measurement of surface activity of alpha- and beta-emitting radionuclides of hands, feet (shoes) and clothing of personnel; measurement of the ambient dose equivalent (MAED) power of gamma radiation.
Doza
Zelenograd
Produced in: Moscow
Power injector IP-2
Power injector IP-2
Purpose: provision of connected equipment with constant voltage; conversion of the RS-485 interface to USB (version 01 only) data transmission via the RS-485 interface (version 02 only).
Doza
Zelenograd
Produced in: Moscow
Individual thermoluminescent dosimeters
Individual thermoluminescent dosimeters
The principle of operation of dosimeters is based on the accumulation of ionizing radiation energy by detectors proportional to the radiation dose. In DVG-02TM installations, DOZA-TLD complexes, etc., when the detector is heated, the accumulated energy is released in the form of light radiation, which is recorded by an electronic device.