EVRAZPRIBOR

EVRAZPRIBOR

15 products
View:
Telephone number:
Address:
Russia, Lipetsk, 8
Address:
Russia, Lipetsk, 8
  • Selected: 0
    Applying
  • Selected: 0
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
    All filters
    • 3
      Applying
    • 6
      Names
    • 1
      Manufacturer
    • 1
      Made in
    • 0
      Additional
      View:
      14 products
      EVRAZCOMB – TSO
      EVRAZCOMB – TSO
      Purpose: Measurement of temperature, oxygen activity and sampling of molten metal Scope of application: Oxygen converters Measurement range: from 1 to 2000 ppm O2 - metal oxidation from 1400 to 1800 °C - metal temperature from 0.010 to 0.200% - carbon content Accuracy: 0 + 3 °C at 1554 °C; (from 5 to 10) mV (depending on the level of oxygen activity) The shape of the selected metal mold: Circle: diameter 34 mm, thickness 12 mm Oval: diameter 34mm, length 42mm, thickness 12 mm Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium Measurement time: 8 sec Tube Length: from 100 to 2500 mm (other lengths are available on request) Slag Cap: Steel, Aluminum, Copper, cardboard Type of NSH: B, S, R
      Produced in: Lipetsk
      EVRAZOXY Universal
      EVRAZOXY Universal
      Purpose: Measurement of oxygen activity in molten steel Scope of application: Oxygen converters, electric arc furnaces, induction furnaces, casting buckets Measurement range: from 1 to 2000 ppm O2 - metal oxidation from 1000 to 1800 °C - metal temperature from 0.010 to 0.200% - carbon content Accuracy: 0 + 3°C at 1554°C; (from 5 to 10) mV (depending on the level of oxygen activity) Measurement time: 8 sec Tube Length: from 100 to 1500 mm (other lengths are available on request) Slag Cap: Steel, cardboard Type of HCX: B, S, R
      Produced in: Lipetsk
      EVRASAMP ESU Sampling of the required configuration
      EVRASAMP ESU Sampling of the required configuration
      Appointment: Sampling for chemical, spectral, etc. analysis of molten metal Scope of application: Induction furnaces, steel ladles, metal finishing plants, filling ladles, etc. Sampler type: Sand shape – sample thickness 6 mm, 8 mm, 10 mm, 12 mm Operating temperature range (depending on the type of sampler): from 1150°C to 2020°C Selection time: from 3 to 5 seconds Tube Length: from 100 to 1500 mm (other lengths are available on request) Slag Cap: Steel, Cardboard, Aluminum Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium
      Produced in: Lipetsk
      Continuous measurement of temperature in the industrial area
      Continuous measurement of temperature in the industrial area
      Appointment: the continuous measurement system allows for continuous measurement of the heating temperature of the industrial bucket, to improve the stability and reliability of measuring the temperature of liquid metal. Due to the fixed measurement position, the system eliminates errors due to the human factor. This method of measuring temperature was researched and invented on the theory of an absolutely black body. The principle of the temperature measurement system is the immersion of a temperature probe into molten steel to determine the temperature. The temperature probe made of an absolutely black body is designed in a special way to receive an infrared radiation signal corresponding to the temperature of molten steel. Scope of application: Intermediate bucket Measuring range: Warming up the promkovsh: from 800°C to 1400°C; Molten steel: from 1400°C to 1600°C Accuracy: Preheating of the promkovsh 7 ° C; Molten steel: 3 ° C Response time: Hot response time 75 sec; Cold response time 4 min Measuring probe length: 964mm, 1100mm Durability of measuring probes: 12 hours, 24 hours, 48 hours Number of thermal shocks: up to 5 times
      Produced in: Lipetsk
      EVRAZ HYDRO Submersible probe For measuring the hydrogen content in steel
      EVRAZ HYDRO Submersible probe For measuring the hydrogen content in steel
      Purpose: Measurement of hydrogen in molten metals Scope of application: Induction furnaces, ladle furnace units, vacuum cleaners, casting ladles of various types, intermediate ladles, crystallizers Measuring range: from 0.5 to 14 ppm H2 Accuracy: 0.5 to 3ppm - 0.1ppm H2 3.0 to 14ppm - 3% H2 Measurement time: up to 60 seconds Reproducibility of results: 0.3% Purpose: Measurement of the percentage of carbon in steel Scope of application: Furnaces, buckets, cupola furnace Measuring range: 0.01 to 2.00% carbon Accuracy: 0.01 %
      Produced in: Lipetsk
      EVRAZCARB For measuring the carbon content in steel
      EVRAZCARB For measuring the carbon content in steel
      Purpose: Measurement of the percentage of carbon in steel Scope of application: Furnaces, buckets, cupola furnace Measuring range: from 0.01 to 2.00% carbon Accuracy: 0.01 %
      Produced in: Lipetsk
      EVRAZTEMP Submersible thermocouples for reusable use
      EVRAZTEMP Submersible thermocouples for reusable use
      Purpose: Measurement of molten metal temperature Scope of application: Induction furnaces, blast furnaces, casting ladles Measuring range: from 600°C to 1800°C Accuracy: 0 + 3°C at 1554°C Measurement time: 4 sec Tube Length: from 100 to 1800 mm (other lengths are available on request) Slag Cap: Steel, uncapped, aluminum Number of measurements: 5 or more times Type of NSH: B, S
      Produced in: Lipetsk
      EVRASAMP ESC Sampling with low carbon content
      EVRASAMP ESC Sampling with low carbon content
      Appointment: Sampling for chemical, spectral, etc. analysis of molten metal Scope of application: Oxygen converters, electric arc furnaces, induction furnaces, vacuum cleaners, steel ladles, filling ladles, etc. Type of sampler: Ceramic sampler with an elongated leg Operating temperature range (depending on the type of sampler): from 1150°C to 2020°C Selection time: from 3 to 5 seconds Tube Length: from 100 to 1500 mm (other lengths are available on request) Slag Cap: Steel, Cardboard, Aluminum Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium
      Produced in: Lipetsk
      EVRAZCOMB – 3 in 1
      EVRAZCOMB – 3 in 1
      Purpose: Measurement of temperature, oxygen activity and sampling of molten metal Scope of application: Oxygen converters, electric arc furnaces, induction furnaces, casting buckets Measuring range: from 1 to 2000 ppm O - metal oxidation from 1400 to 1800 °C - metal temperature from 0.010 to 0.200% - carbon content Accuracy: 0 + 3 °C at 1554 °C; (from 5 to 10) mV (depending on the oxygen activity level) The shape of the selected metal shape: Circle: thickness 12 mm Oval: thickness 12 mm Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium Measurement time: 8 sec Tube Length: from 100 to 2500 mm (other length is possible on request) Slag Cap: Steel, Aluminum, Copper, cardboard Type of NSH: B, S, R
      Produced in: Lipetsk
      EVRASAMP ES Sampling of the required configuration
      EVRASAMP ES Sampling of the required configuration
      Appointment: Sampling for chemical, spectral, etc. analysis of molten metal Scope of application: Oxygen converters, electric arc furnaces, induction furnaces, vacuum cleaners, steel ladles, filling ladles, etc. Sampler type: with a ladder - oval shape, circle Operating temperature range (depending on the type of sampler): from 1460°C to 2020°C Selection time: from 3 to 5 seconds Tube length: from 100 to 1500 mm (other length is possible on request) Slag Cap: Steel, Cardboard, Aluminum Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium
      Produced in: Lipetsk
      EVRAZCOMB – TSC
      EVRAZCOMB – TSC
      Purpose: Temperature measurement, sampling of molten metal Scope of application: Oxygen converters Measuring range: from 1400 to 1800 °C - metal temperature from 0.010 to 0.200% - carbon content Accuracy: 0 + 3 °C at 1554 °C; (from 5 to 10) mV (depending on the oxygen activity level) The shape of the selected metal mold: Circle: diameter 34 mm, thickness 12 mm Oval: diameter 34mm, length 42mm, thickness 12 mm Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium Measurement time: 8 sec Tube Length: from 100 to 2500 mm (other lengths are available on request) Slag Cap: Steel, Aluminum, Copper, cardboard Type of NSH: B, S, R
      Produced in: Lipetsk
      EVRAZOXY For high oxidation
      EVRAZOXY For high oxidation
      Purpose: Measurement of oxygen activity in molten steel Scope of application: Oxygen converters, electric arc furnaces, induction furnaces, blast furnaces, casting buckets Measurement range: from 50 to 2000 ppm O2 - metal oxidation from 1000 to 1800 °C - metal temperature from 0.010 to 0.200% - carbon content Accuracy: 0 + 3°C at 1554°C; (from 5 to 10) mV (depending on the level of oxygen activity) Measurement time: 8 sec Tube Length: from 100 to 1500 mm (other lengths are available on request) Slag Cap: Steel, cardboard Type of NSH: B, S, R
      Produced in: Lipetsk