Vakuummash

Vakuummash

170 products
View:
Telephone number:
Address:
Russia, Kazan
Address:
Russia, Kazan
  • Selected: 0
    Applying
  • Selected: 0
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • 1
    Applying
  • 10
    Names
  • 1
    Manufacturer
  • 1
    Made in
  • 1
    Additional
View:
156 products
Copper gaskets for CF flanges
Copper gaskets for CF flanges
Copper gaskets for CF flanges (oxygen-free copper).
Produced in: Kazan
Crimp support rings (stainless steel) for sealing rings with high sealing capacity
Crimp support rings (stainless steel) for sealing rings with high sealing capacity
The ISO-KF connection (DIN 28 403 and ISO 2861) allows quick installation and replacement of components in vacuum systems. The connection consists of two symmetrical ISO-KF flanges (1), a centering ring with an O-ring seal (2) and a quick-release clamp (3). High-vacuum ISO-KF connections can be mounted without using a tool by simply turning the nut of the quick-release clamp.
Produced in: Kazan
2ZVE-100 Electromechanical Vacuum shutter
2ZVE-100 Electromechanical Vacuum shutter
The 2ZVE-100 vacuum shutter with electromechanical drive equipped with conditional passages of 100 mm is designed to overlap vacuum systems in the range of operating pressures from 1x10-6 to 1.07x105 Pa (0.75 x10–8 to 800 mm Hg). Type of shutter 2ZVE-100 pendulum. The 23VE-100 shutter is manufactured in the climatic version of UHL (i.e. for moderate and cold climate) and O (i.e. general) 4 according to GOST 15150-69. The working environment is air and non–aggressive gases and. It is not intended for use in fire and explosive hazardous industries. The 23VE-100 shutter meets the requirements of technical specifications TU 3648-040-00218526-2003. According to the method of protecting a person from electric shock, the gate belongs to Class I electrical equipment according to GOST 12.2.007.0-75.
Produced in: Kazan
Spare ring gaskets for flanges
Spare ring gaskets for flanges
The ISO-KF connection (DIN 28 403 and ISO 2861) allows quick installation and replacement of components in vacuum systems. The connection consists of two symmetrical ISO-KF flanges (1), a centering ring with an O-ring seal (2) and a quick-release clamp (3). High-vacuum ISO-KF connections can be mounted without using a tool by simply turning the nut of the quick-release clamp. The dimensions of the DN are 10,16,20,25,32,40,50.
Produced in: Kazan
ND-400 High-vacuum Diffusion pump
ND-400 High-vacuum Diffusion pump
The working condition of the ND-400(R) diffusion pump depends on the temperature of the working fluid in the pump boiler. During the initial filling, it is recommended to fill the maximum volume of the working fluid. Working fluid is "VACMA OIL 500" vacuum oil (under technical specifications TU 19.20.29-061-00218526-2019). The total amount of working fluid in the ND-400(R) diffusion pump is a maximum of 5 liters, a minimum of 3.3 liters. The viewing window for visual inspection of the working fluid has marks of its maximum and minimum amounts. During normal operation of the pump, the level of the working fluid practically does not change. The temperature of the working fluid when the pump is operating at the maximum residual pressure is about 240°C to 255°C. It is recommended to monitor the operation of heaters in the ND-400(R) diffusion pump using one temperature sensor. The temperature sensor must be installed in a special radiator socket above the heater. If there is a loss of working fluid and an increase in the temperature of the radiators of the ND-400(P) diffusion pump to 320°C, the temperature sensor must give the command to automatically turn off the heaters. The subsequent activation of the pump heaters should not be automatic and should be performed only after cooling the system. Water at the inlet to the cooling systems of the housing and the oil reflector must be supplied with a pressure of 0.3 MPa (3 kgf/cm2) to 0.5 MPa (5 kgf/cm2) and a temperature of plus 4°C to plus 25°C. The recommended cooling water consumption for the housing is 250 l/h, for the oil reflector it is 40 l / h. It is regulated by the outlet water temperature, which should not exceed plus 40°C. The water drain should be free (with a jet break).
Produced in: Kazan
2NVBM-630/18000 Booster high vacuum pump
2NVBM-630/18000 Booster high vacuum pump
The 2NVBM-630(R)/18000 pump is designed for pumping out of sealed volumes of air, gases, vapors and vapor-gas mixtures that are non-aggressive to the materials of the structure and the working fluid of the pump in the range of inlet pressures from 13.3 to 6.6x10-2 Pa (from 1x10-1 to 5x10-4 mmHg.) and do not contain droplet moisture and mechanical impurities. The 2NVBM-630(R)/18000 pump is used in conjunction with pre-vacuum pumps as part of technological installations or systems in stationary conditions. The type of climatic version of UHL4 and O4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, but it is intended for operation at ambient temperature from plus 10°C to plus 35°C for UHL4 and from plus 10°C to plus 45°C for O4, at cooling water temperature from plus 10°C to plus 20°C. The 2NVBM-630(R)/18000 pump is not intended for use in fire dangerous and explosive industries.
Produced in: Kazan
50M URS special manual vacuum angle valve
50M URS special manual vacuum angle valve
The body of the 50M URS valve is of welded construction and consists of a shell, a seat, side and lower nozzles. The lower branch pipe of the 50M URS valve is connected to the vacuum system using welding. The smooth part of the stem serves as a visual indicator of the "open" or “closed” valve positions. The casing is designed to protect the valve from accidental openings, and also serves as additional protection against precipitation, sand, dust entering the inner cavity of the valve. The valve opens when the flywheel rotates counterclockwise. The valve closes when the flywheel rotates clockwise.
Produced in: Kazan
LAP-400P Nitrogen Flow Vacuum Trap
LAP-400P Nitrogen Flow Vacuum Trap
The nitrogen flow trap LAP-400P is designed to protect vacuum pumps from contamination in the form of vapors of resins, oils and adhesives by freezing them on cooled surfaces with the possibility of their removal, and to prevent the penetration of vapors of working fluids of vacuum pumps into the pumped vessel.
Produced in: Kazan
LAP-100P Nitrogen Flow Vacuum Trap
LAP-100P Nitrogen Flow Vacuum Trap
The nitrogen flow trap LAP-100P is designed to protect vacuum pumps from contamination in the form of vapors of resins, oils and adhesives by freezing them on cooled surfaces with the possibility of their removal, and to prevent the penetration of vapors of working fluids of vacuum pumps into the pumped vessel.
Produced in: Kazan
NVDM-100 High-vacuum Diffusion Pump
NVDM-100 High-vacuum Diffusion Pump
The operation of the NVDM-100 diffusion pump is based on the capture and transfer of the pumped gas by a steam jet flowing from the slit gaps of the steam line nozzles towards the outlet flange. The oil reflector of the NVDM-100 diffusion pump is a cap with a cooling tube soldered onto it with fittings. The open heater of the NVDM-100 diffusion pump is a metal housing with a ceramic base laid in it with a heating element made in the form of a spiral of nichrome wire. During the operation of the pump, it is necessary to monitor the flow rate and temperature of the cooling water, the level of the working fluid and its temperature. Replacement or refilling of the working fluid depends on the operating mode of the pump (inlet pressure, pumping duration, etc.) and the composition of the pumped medium. Therefore, the time after which the working fluid is replaced or refilled can be from 100 to 1000 or more hours. A large flow rate of the working fluid is observed when the pump is operating in the range of inlet pressures from 6.6×10-2 to 13.3 Pa (from 5×10-4 to 1×10-1 mm Hg). Water at the inlet to the cooling systems of the housing and oil reflector should be supplied with a pressure of no more than 0.5 MPa (5 kgf / cm2) and temperature from plus 4˚C to plus 25˚C. The recommended cooling water consumption is 35+5 l/h and is regulated by the outlet water temperature, which should not exceed plus 40˚C. The water drain should be free (with a jet break). Not allowed: operation of the pump without water cooling, exceeding the maximum exhaust pressure of 35 Pa (0.263 mm Hg). The level of the working fluid during operation, at which the parameters of the NVDM-100 diffusion pump are provided, must correspond to min 7mm, max 11mm. The volume of the filled working fluid is 0.07/
Produced in: Kazan
3VVN1-12M Water ring vacuum pump
3VVN1-12M Water ring vacuum pump
The working fluid of the pump is water. The use of the 3VVN1-12M(H) pump for pumping out water-gas mixtures is allowed only if the bulk of the water is separated and discharged at the pump entrance. Failure to comply with this requirement may lead to unacceptable overload of the engine and destruction of the pump's working parts. The 3VVN1-12M(H) water ring vacuum pump is not intended for use in fire and explosion hazardous industries. The 3VVN1-12M(H) vacuum water ring pump is manufactured in the climatic version of UHL 4 and O4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, meets the requirements of technical specifications TU 3648-053-00218526-2013, designed and manufactured taking into account the requirements of GOST R 52615-2006.
Produced in: Kazan
2NVR-250D Vacuum rotary vane pump
2NVR-250D Vacuum rotary vane pump
the 2NVR-250D vacuum pump is manufactured in the climatic version of UM 4 (i.e. for moderate climate) according to GOST standard 15150-69, but to be used at ambient temperature and pumped medium 283 K to 308 K (+10˚C to +35˚C). Electricity grid must meet the requrimemnts of GOST 13109-97. The 2NVR-250D vacuum rotary vane pump meets the requirements of technical specifications TU 3648-006-00218526-2002. The 2NVR-250D pump is refueled with VACMA OIL 100 power fluid. The level of the working fluid is monitored by the oil indicator, replenishment is needed when the level of the power fluid is below the minimum level of the oil indicator.
Produced in: Kazan