Vakuummash

Vakuummash

170 products
View:
Telephone number:
Address:
Russia, Kazan
Address:
Russia, Kazan
  • Selected: 0
    Applying
  • Selected: 0
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • 1
    Applying
  • 10
    Names
  • 1
    Manufacturer
  • 1
    Made in
  • 1
    Additional
View:
156 products
AVDM-100 High-vacuum Diffusion Unit
AVDM-100 High-vacuum Diffusion Unit
The AVDM-100 high-vacuum unit consists of a vacuum diffusion oil-vapor pump, a nitrogen trap, a vacuum gate, a frame or a plate. The principle of operation of the AVDM-100 unit is based on the pumping action of a vacuum diffusion steam oil pump. When the AVDM-100 unit is operating, liquid nitrogen is poured into the trap. Condensation of working fluid vapors occurs on the elements of the freezing device cooled with liquid nitrogen. The frame (plate) is designed for mounting the components of the unit. The ends of the wiring wires are connected to the connector fixed on the plate of the AVDM-100 unit.
Produced in: Kazan
CF Rotating Flanges
CF Rotating Flanges
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
Produced in: Kazan
ND-500 High-vacuum diffusion pump
ND-500 High-vacuum diffusion pump
The working condition of the ND-500 diffusion pump depends on the temperature of the working fluid in the pump boiler. During the initial filling, it is recommended to fill the maximum volume of the working fluid. Working fluid is "VACMA OIL 500" vacuum oil (under technical specifications TU 19.20.29-061-00218526-2019). The total amount of working fluid in the ND-500 diffusion pump is a maximum of 5.5 liters, a minimum of 4 liters. The viewing window for visual inspection of the working fluid has marks of its maximum and minimum amounts. During normal operation of the pump, the level of the working fluid practically does not change.The temperature of the working fluid when the pump is operating at the maximum residual pressure is about 240°C to 255°C. It is recommended to monitor the operation of the heaters in the ND-500 diffusion pump using one temperature sensor. The temperature sensor must be installed in a special radiator socket above the heater. If there is a loss of working fluid and an increase in the temperature of the radiators of the ND-500 diffusion pump up to 320°C, the temperature sensor should give the command to automatically turn off the heaters. The subsequent activation of the pump heaters should not be automatic and should be carried out only after cooling the system. Water at the inlet to the cooling systems of the housing and the oil reflector must be supplied with a pressure of 0.3 MPa (3 kgf/cm2) to 0.5 MPa (5 kgf/cm2) and a temperature of plus 4 ° C to plus 25 ° C. The recommended cooling water consumption for the housing is 500 l/h, for the oil reflector it is 50 l / h. It is regulated by the outlet water temperature, which should not exceed plus 40°C. The water drain should be free (with a jet break). The required speed of action of pre-vacuum pumps at a pressure of 26 Pa (0.2 mm Hg.st) in the outlet section of the ND-500 diffusion pump should be at least 42 l/s. To reduce the losses of the working fluid of the ND-500 diffusion pump at pressures (1·10-1- 1) Pa [(7,5·10-4- 7,5·10-3) mmHg] it is recommended to install an additional LP-500 flow-through water trap on the outlet flange.
Produced in: Kazan
NVSp-4 Spiral Vacuum Pump
NVSp-4 Spiral Vacuum Pump
The NVSp-4 dry vacuum spiral pump can operate continuously at an inlet pressure of no more than 10 kPa (75 mm Hg), pumping out one or more sealed vessels with a total volume of no more than 0.7 m3 from atmospheric to residual pressure during the day. Pumping of vessels of the specified volume with leakage is allowed, but the leakage should not cause an increase in pressure at the pump inlet of more than 10 kPa (75 mm Hg).
Produced in: Kazan
2ZVE-250R Electromechanical vacuum shutter with gearbox
2ZVE-250R Electromechanical vacuum shutter with gearbox
The 2ZVE-250R vacuum shutter with electromechanical drive equipped with 250mm conditional passages is designed to overlap vacuum systems in the range of operating pressures from 1x10-6 to 1.07x105 Pa (0.75x10–8 to 800 mm Hg). The 2ZVE-250R shutter is pendulum-type. The 23VE-250R shutter is manufactured in the climatic version UHL (i.e. for moderate and cold climate) and O (i.e. general) 4 according to GOST standard 15150-69. The working environment is air and non–aggressive gases. It is not intended for use in fire and explosive hazardous industries. The 23VE-250R shutter meets the requirements of technical specifications TU 3648-040-00218526-2003. According to the method of protecting a person from electric shock, the gate belongs to Class I electrical equipment according to GOST 12.2.007.0-75.
Produced in: Kazan
LP-1000 Flow Vacuum Trap
LP-1000 Flow Vacuum Trap
The LP-1000 flow water trap is installed on the inlet flange of the diffusion pump and is designed to reduce the flow of working fluid vapors into the pumped volume by condensing them on the cooled elements of the freezing device.
Produced in: Kazan
Crimping centering rings (aluminum) with O-ring of circular cross-section
Crimping centering rings (aluminum) with O-ring of circular cross-section
The ISO-KF connection (DIN 28 403 and ISO 2861) allows quick installation and replacement of components in vacuum systems. The connection consists of two symmetrical ISO-KF flanges (1), a centering ring with an O-ring seal (2) and a quick-release clamp (3). High-vacuum ISO-KF connections can be mounted without using a tool by simply turning the nut of the quick-release clamp.
Produced in: Kazan
Plugs for vacuum connections
Plugs for vacuum connections
Claw clamps in the groove of the base plate (galvanized steel) for ISO-K.
Produced in: Kazan
2VVN1-12M(N) Water ring vacuum pump
2VVN1-12M(N) Water ring vacuum pump
The use of a 2VVN1-12M(H) water-ring vacuum pump for pumping out water-gas mixtures is allowed only if the bulk of the water is separated and discharged at the pump entrance. Failure to comply with this requirement may lead to unacceptable overload of the electric motor and destruction of the working parts of the 2VVN1-12M(N) pump. The 2VVN1-12M(N) vacuum water ring pump is manufactured in the climatic version of UHL 4 and O4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, meets the requirements of technical specifications TU 3648-015-00218526-2000, designed and manufactured taking into account the requirements of GOST R 52615-2006. The quality of electricity must meet the requrimemnts of GOST 32144-2013.
Produced in: Kazan
Bolts with mounting plate and gaskets
Bolts with mounting plate and gaskets
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
Produced in: Kazan
MU-630 Enlarged oil reflector
MU-630 Enlarged oil reflector
The MU-800 flanged enlarged oil reflector performs the function of an oil reflector, is installed instead of a standard oil reflector in ND pumps and has an additional number of cooled screens to capture oil return flow vapors.
Produced in: Kazan
Non-rotating CF flanges
Non-rotating CF flanges
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
Produced in: Kazan