conductometer MARK® 1102
conductometer MARK® 1102
Measurement of specific electrical conductivity (UEP, UEP25) and mass fraction (C) of solutes (NaCl, NaOH, HNO3, H2SO4, HCl) in water. Control of water-chemical regimes at thermal and nuclear power facilities.Contactless inductive sensor resistant to aggressive environments | Two channels | Freely programmable measurement ranges. The possibility of independent measurements at two points. The possibility of placing the converter unit at a remote distance from the sampling point | Up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. Programmable setpoints with "dry contact" type output. Durable aluminum housing IP65 | The device is reliably protected from dust and moisture. Graphic indicator with backlight | Convenient data presentation format and ease of settings. Submersible, trunk, flow fittings |
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
MARK -1202
MARK -1202
The device is designed for high-precision measurements of silicon dioxide in process waters of thermal and nuclear power plants, for monitoring water treatment processes in various industries. The device is based on a photometric measurement method with automatic dosing of reagents. MARK-1202 can be used not only as an automatic, but also as a laboratory analyzer. The warranty is 24 months for deliveries across the Russian Federation. Multithreaded analysis capability From 1 to 6 channels Current outputs, RS-485 digital interface Universal analyzer for automatic and laboratory control Minimum maintenance Self-diagnosis Graduation no more than once every 3 months Low cost of operation Reagents of Russian production Simple, intuitive interface Color touch screen
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
pH meter MARK® 902 MP
pH meter MARK® 902 MP
Measurement of hydrogen ion activity (pH) and temperature of aqueous media. pH control of water media in technological processes, including treatment facilities. Two channels Freely programmable measurement ranges. The possibility of independent measurements at two points. Convenience and accuracy of measurement, minimum maintenance | Calibration according to standard buffer solutions with their automatic determination. Universal trunk-submersible "active" sensor unit | The digital communication channel of the sensor with the converter unit is up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. MODBUS RTU exchange protocol. Programmable setpoints with a "dry contact" type output. Durable aluminum housing IP65 | The device is reliably protected from dust and moisture. Graphic indicator with backlight | Convenient data presentation format and ease of settings
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
conductometer MARK® 602 MP
conductometer MARK® 602 MP
Measurement of electrical conductivity (UEP, UEP25) and salinity of aqueous media, including "ultrapure", in the main and flow modes. Control of water-chemical regimes at thermal and nuclear power facilities, including control of cooling water suction in the turbine condenser.Two channels | Freely programmable measurement ranges. The possibility of independent measurements at two points. Convenience and accuracy of measurement, minimum maintenance | Double automatic thermal compensation. The possibility of placing the converter unit at a remote distance from the sampling point | Up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. Programmable setpoints with "dry contact" type output. Durable aluminum housing IP65 | The device is reliably protected from dust and moisture. Graphic indicator with backlight | Convenient data presentation format and ease of settings.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
Hydrogen meter MARK 501
Hydrogen meter MARK 501
Measurement of mass concentration in liquid and volume fraction of hydrogen in gases, temperature Monitoring of concentrations (including small ones) of dissolved hydrogen at energy facilities, in technological processes in various industries: in a gas trap, in bearing crankcases, shielded current lines, linings and zero terminals, residual hydrogen in oxygen after electrolysis; oxygen content in hydrogen inside the generator housing, in a float hydraulic seal, tank purge and hydrogen separation tank of the generator oil cleaning unit. 24 months warranty for deliveries across the Russian Federation Automatic temperature and barocompensation Three measurement modes KRV (concentration of dissolved hydrogen), mcg/dm3 % of volume share Temperature, °C Long-lasting, highly stable sensor The service life of the hydrogen sensor is at least 10 years High contrast LCD indicator Low power consumption Up to 2000 hours of continuous operation from a set of AA type elements Easy calibration with a standard calibrator
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
Oxygen meter MARK® 3010
Oxygen meter MARK® 3010
Measurement of dissolved oxygen concentration and temperature of aqueous media, including deaerated ones. Operational control of water-chemical regimes at thermal and nuclear power facilities. Warranty 24 months for deliveries across the Russian Federation Measurement error ± (0.001+0.04 *A) mg/dm3 (A is the measured value). The ability to work on small flows (from 20 ml / min). Air oxygen calibration is not more than 1 time per month. Routine maintenance 1 time per year. Universal mechanism for direct connection to the process. NEW highly stable sensor High reaction speed. Sealed heavy-duty hydrophobic membrane. Increased mechanical strength of the structure. "Sleep" mode when stored in the air. Organic high contrast LED indicator Full protection from dust and moisture – housing-case IP65 Built-in long-lasting LiFePO4 battery (at least 1000 charge/discharge cycles) Carrying strap
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
MARK-409T Dissolved Oxygen Analyzer
MARK-409T Dissolved Oxygen Analyzer
Measurement of dissolved oxygen concentration and temperature of aqueous media, including deaerated ones.Convenience and accuracy of measurement | The measurement error is ±(0.001 + 0.035 *A) mg/dm3, (A is the measured value). The ability to work on small flows (from 25 ml / min). Routine maintenance 1 time per year. Highly stable sensor | High reaction speed. Sealed heavy-duty hydrophobic membrane. Increased mechanical strength of the structure. Two channels | Freely programmable measurement ranges. The possibility of independent measurements at two points. The possibility of placing the converter unit at a remote distance from the sampling point | Up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. MODBUS RTU exchange protocol. Hydropanel GP 409 T | The possibility of placing the measuring complex on a single panel. The supply lines are stainless steel. Routine maintenance and calibration of the sensor – without interrupting the flow. Continuous monitoring of water-chemical regimes at thermal and nuclear power facilities.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
Oxygen meter MARK® 303 T
Oxygen meter MARK® 303 T
Convenience and accuracy of measurement | Automatic temperature and barocompensation, air oxygen calibration. Measurement modes | KRK and temperature. IP65 | Compact sealed device is reliably protected from dust and moisture. Non-volatile electronic notebook | The ability to record up to 500 measurement groups in User-named folders. USB port, software included | The ability to create and manage a data archive on a PC. Graphic indicator with backlight | Indication of readings in a user-friendly format, ease of settings. Long-lasting sensor | Sensor service life of at least 10 years. Low power consumption | Up to 600 hours of continuous operation from a set of AA elements. Designed for "operational" monitoring | "Fast" sensor – the measurement time is no more than 3 minutes. Illumination for work in darkened rooms. Record measurements at the touch of a button. Self-diagnosis | Additional guarantee of correct operation of the device
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
MARK-409 Dissolved Oxygen Analyzer
MARK-409 Dissolved Oxygen Analyzer
Measurement of dissolved oxygen concentration and temperature of aqueous media, including deaerated ones. Continuous monitoring of water-chemical regimes at thermal and nuclear power facilities. Two channels Freely programmable measurement ranges. The possibility of independent measurements at two points. Convenience and accuracy of measurement, minimum maintenance Automatic temperature and barocompensation. Automatic air oxygen calibration. Long-lasting sensor The service life of the sensor is at least 10 years. The possibility of placing the converter unit at a remote distance from the sampling point Up to 100 meters. Communication with external devices Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port, MODBUS RTU exchange protocol. Programmable setpoints with a "dry contact" type output. Durable IP65 aluminum housing The device is reliably protected from dust and moisture. Graphic indicator with backlight Convenient data presentation format and ease of settings
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
pH Analyzer MARK® 9010
pH Analyzer MARK® 9010
Measurement of the activity of hydrogen ions (pH, pH25) of "ultrapure" waters (including water with a reduced electrical conductivity of 0.055 microns /cm) and alkaline waters containing ammonia or amines. Measurement of electrical conductivity (UEP, UEP25), temperature of aqueous media. Control of water-chemical regimes at energy facilities. A new patented measurement method that does not require calibration. The absence of elements that degrade in "ultrapure" water. Convenience and accuracy of measurement | Automatic thermal compensation. Freely programmable measurement ranges. Measurement of conductivity in the range up to 30 microns/cm. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. MODBUS RTU exchange protocol. Relay of "dry" contacts (6 pcs.) with programmable functions. Durable aluminum housing IP65 | The device is reliably protected from dust and moisture. A single protective box that combines the secondary converter and the hydraulic part. Intelligent data processing algorithms. 5.7" graphic touchscreen display, 65535 colors, resolution 640*480 pixels.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
MARK® 01 MK
MARK® 01 MK
Cooling, throttling, filtration and regulation of sample flow. Indication of temperature, pressure and flow of the sample. Temperature, pressure and cooling water flow indication (optional). Sample preparation for water-chemical regime monitoring devices at energy facilities. Continuous monitoring of sample parameters and data transmission via digital and current outputs. Maintaining stable sample pressure. Alarm and automatic shut-off of the sample supply in case of violation of the regime. Custom temperature and pressure settings for automatic shut -off of sample supply. Pulse line purge valve. Compact stainless steel panel 350*944 mm. One-way service. Easy-to-clean collapsible heat exchanger.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
pH-metrMARK® 902 / MARK® 902A
pH-metrMARK® 902 / MARK® 902A
Measurement of the activity of hydrogen ions (pH, pH25), EMF and temperature of aqueous media. Control of water-chemical regimes at thermal and nuclear power facilities. pH control of aqueous media in technological processes.Two channels | Freely programmable measurement ranges. The possibility of independent measurements at two points. Convenience and accuracy of measurement, minimum maintenance | Automatic thermal compensation. Calibration according to standard buffer solutions with their automatic determination. "Active" sensor unit | The digital communication channel of the sensor with the converter unit is up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. MODBUS RTU exchange protocol. Programmable setpoints with a "dry contact" type output. Durable aluminum housing IP65 | The device is reliably protected from dust and moisture. Graphic indicator with backlight | Convenient data presentation format and ease of settings
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod