VZOR

VZOR

32 products
View:
Telephone number:
Address:
Russia, Nizhny Novgorod, 33
Address:
Russia, Nizhny Novgorod, 33
  • Selected: 0
    Applying
  • Selected: 0
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • 5
    Applying
  • 9
    Names
  • 1
    Manufacturer
  • 2
    Made in
  • 7
    Additional
View:
32 products
conductometer MARK® 602
conductometer MARK® 602
Measurement of electrical conductivity (UEP, UEP25) and salinity of aqueous media, including "ultrapure". Control of water-chemical regimes at thermal and nuclear power facilities. Specialized water treatment.Two channels | Freely programmable measurement ranges. The possibility of independent measurements at two points. Convenience and accuracy of measurement, minimum maintenance | Double automatic thermal compensation. The possibility of placing the converter unit at a remote distance from the sampling point | Up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. Programmable setpoints with a "dry contact" type output. Durable aluminum housing IP65 | The device is reliably protected from dust and moisture. Graphic indicator with backlight | Convenient data presentation format and ease of settings
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
MARK-409 Dissolved Oxygen Analyzer
MARK-409 Dissolved Oxygen Analyzer
Measurement of dissolved oxygen concentration and temperature of aqueous media, including deaerated ones. Continuous monitoring of water-chemical regimes at thermal and nuclear power facilities. Two channels Freely programmable measurement ranges. The possibility of independent measurements at two points. Convenience and accuracy of measurement, minimum maintenance Automatic temperature and barocompensation. Automatic air oxygen calibration. Long-lasting sensor The service life of the sensor is at least 10 years. The possibility of placing the converter unit at a remote distance from the sampling point Up to 100 meters. Communication with external devices Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port, MODBUS RTU exchange protocol. Programmable setpoints with a "dry contact" type output. Durable IP65 aluminum housing The device is reliably protected from dust and moisture. Graphic indicator with backlight Convenient data presentation format and ease of settings
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
Na-meter MARK® 1002
Na-meter MARK® 1002
Measurement of the activity of sodium ions (CNa) and the temperature of aqueous media. Control of parameters of water-chemical regimes at thermal and nuclear power facilities.Two channels | Freely programmable measurement ranges. The possibility of independent measurements at two points of CNa or pNa, temperature. Convenience and accuracy of measurement, minimum maintenance | Measurements from 0.01 CNa. The typical error is 6%. Long intergrading interval (up to 6 months). Automatic thermal compensation. Automatic dosing device of the alkalizing reagent. No capacity with KCl. Calibration by one solution | If necessary, three-point calibration is possible. "Active" sensor unit | The digital communication channel of the sensor with the converter unit is up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. MODBUS RTU exchange protocol. Programmable settings of the "dry" contact type.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
pH meter MARK® 903
pH meter MARK® 903
Measurement of the activity of hydrogen ions (pH, pH25), ORP, EMF and temperature of aqueous media. Operational control of parameters of water-chemical regimes at thermal and nuclear power facilities, in accordance with CO 153-34.37.303. Convenience and accuracy of measurement | Automatic temperature compensation. Automatic recognition of buffer solutions. Measurement modes | pH or pH25 and temperature. EMF and temperature. pH measurement in flow and immersion modes | The flow-filling module MPN 901/903 is included. Self-diagnosis | Non-volatile electronic notebook | The ability to record up to 500 measurement groups in User-named folders. USB port, software included | The ability to create and manage a data archive on a PC. Graphic indicator with backlight | Indication of readings in a user-friendly format. Ease of settings. IP65 | Compact sealed device is reliably protected from dust and moisture. Low power consumption | Up to 600 hours of continuous operation from a set of AA elements.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
MARK-409T Dissolved Oxygen Analyzer
MARK-409T Dissolved Oxygen Analyzer
Measurement of dissolved oxygen concentration and temperature of aqueous media, including deaerated ones.Convenience and accuracy of measurement | The measurement error is ±(0.001 + 0.035 *A) mg/dm3, (A is the measured value). The ability to work on small flows (from 25 ml / min). Routine maintenance 1 time per year. Highly stable sensor | High reaction speed. Sealed heavy-duty hydrophobic membrane. Increased mechanical strength of the structure. Two channels | Freely programmable measurement ranges. The possibility of independent measurements at two points. The possibility of placing the converter unit at a remote distance from the sampling point | Up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. MODBUS RTU exchange protocol. Hydropanel GP 409 T | The possibility of placing the measuring complex on a single panel. The supply lines are stainless steel. Routine maintenance and calibration of the sensor – without interrupting the flow. Continuous monitoring of water-chemical regimes at thermal and nuclear power facilities.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
pH meter MARK-903
pH meter MARK-903
Measurement of the activity of hydrogen ions (pH), ORP, EMF and temperature of aqueous media. Laboratory and "field" measurements in various industries and national economy. 24-month warranty for deliveries across the Russian Federation (the electrode system is guaranteed by the manufacturer IP65 The compact sealed device is reliably protected from dust and moisture Convenience and accuracy of measurement Automatic temperature compensation Automatic recognition of buffer solutions Self-diagnosis Non-volatile electronic notebook Ability to record up to 500 measurement groups in User-named folders USB port, software included Ability to create and manage a data archive on a PC Graphic indicator with backlight Indication of readings in a user-friendly format. Ease of settings. Protective cover Convenience during transportation and "field" measurements Low power consumption Up to 600 hours of continuous operation from a set of AA type elements
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
MARK-603
MARK-603
Measurement of electrical conductivity (UEP, UEP25), equivalent salinity and temperature of water and aqueous solutions, including deionized and "ultrapure". Operational control of water-chemical regimes at thermal power facilities. Control of electrical conductivity of water for laboratory analysis of 1, 2 degrees of purity according to GOST 52501-2005. 24-month warranty for deliveries across the Russian Federation Double automatic temperature compensation (ATC) Allows high-precision measurements of the conductivity of "ultrapure" water Selection of the coefficient of thermal compensation at the request of the User Stainless steel flow-immersion sensor Does not require calibration. The sensor design ensures the stability of the permanent cell Electronic notebook Ability to record up to 500 measurement groups in User-named folders Self-diagnosis Ion exchange column with sample current switch IP65 The compact sealed device is reliably protected from dust and moisture USB port, software included Graphic indicator with backlight Low power consumption Up to 600 hours of continuous operation from a set of AA type elements
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
Oxygen meter MARK® 303 M
Oxygen meter MARK® 303 M
Measurement of dissolved oxygen concentration (CRC) and temperature of aqueous media. Laboratory and "field" measurements. Definition of BOD. The sensor is designed specifically for BOD measurement according to the PNF F method 14.1:2:3:4.123-97. 24-month warranty for deliveries across the Russian Federation Convenience and accuracy of measurement | Automatic temperature and barocompensation. Automatic air oxygen calibration. IP65 | Compact sealed device is reliably protected from dust and moisture. Electronic notebook | The ability to record up to 500 measurement groups in User-named folders. USB port, software | The ability to create and manage a data archive on a PC. Graphic indicator with backlight | Indication of readings in a user-friendly format, ease of settings. Easy calibration by air | Minimum maintenance | Replacement of the membrane no more than once a year. Storage of the sensor in the air. Long-lasting sensor | Sensor service life of at least 10 years.Time to failure - 40,000 hours Low power consumption | Up to 600 hours of continuous operation from a set of AA elements. Designed for "field" measurements | Measurement of the KRK at a depth of up to 20 meters. Self-diagnosis | Additional guarantee of correct operation of the device
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
pH meter MARK® 902 MP
pH meter MARK® 902 MP
Measurement of hydrogen ion activity (pH) and temperature of aqueous media. pH control of water media in technological processes, including treatment facilities. Two channels Freely programmable measurement ranges. The possibility of independent measurements at two points. Convenience and accuracy of measurement, minimum maintenance | Calibration according to standard buffer solutions with their automatic determination. Universal trunk-submersible "active" sensor unit | The digital communication channel of the sensor with the converter unit is up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. MODBUS RTU exchange protocol. Programmable setpoints with a "dry contact" type output. Durable aluminum housing IP65 | The device is reliably protected from dust and moisture. Graphic indicator with backlight | Convenient data presentation format and ease of settings
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
Oxygen meter MARK® 409 A
Oxygen meter MARK® 409 A
Continuous measurement of dissolved oxygen concentration and temperature of aqueous media with excessive hydrostatic pressure.Two independent measurement channels Freely programmable measurement ranges Stability of operation with changes in hydrostatic pressure Permissible short-term (up to 5 min) pressure overload (water hammer) up to 40 MPa High reaction speed. The time to establish the analyzer readings is 2 minutes. Easy and quick replacement of the membrane The sensor is not afraid of "drying out" The content of dissolved hydrogen in the analyzed medium is taken into account The grading interval is 1 month The verification interval is 24 months
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
pH meter MARK-904
pH meter MARK-904
Measurement of the activity of hydrogen ions (pH, pH25), EMF and temperature of aqueous media. Laboratory measurements in various industries and national economy. 24-month warranty for deliveries across the Russian Federation Convenience and accuracy of measurement Automatic temperature compensation. Automatic recognition of buffer solutions. Self-diagnosis Non-volatile electronic notebook Ability to record up to 500 measurement groups in named The user of the folder. USB port, software included The ability to create and manage a data archive on a PC. Graphic indicator with backlight Indication of readings in a user-friendly format. Ease of settings.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
MARK-5010 Hydrogen Purity Analyzer
MARK-5010 Hydrogen Purity Analyzer
High-precision measurements of hydrogen concentration in the range of 95-100% Monitoring of the operation of electrolyzers, control of hydrogen purity in the processes of hydrogen cooling of generators, in the technological processes of chemical, petrochemical, metallurgical and other industries 24 months warranty for deliveries across the Russian Federation A new patented measurement method The device does not require calibration Selectivity of measurement Direct method of measuring molecular hydrogen Insensitivity to humidity, carbon dioxide, oil vapor Measurement time 3-5 min Simple, intuitive interface Minimum maintenance Self-diagnosis Routine maintenance no more than 1 time per year Long-lasting, highly stable sensor The service life of the sensor is at least 10 years Color touch screen
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod, Moscow