VZOR

VZOR

32 products
View:
Telephone number:
Address:
Russia, Nizhny Novgorod, 33
Address:
Russia, Nizhny Novgorod, 33
  • Selected: 0
    Applying
  • Selected: 0
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • 5
    Applying
  • 9
    Names
  • 1
    Manufacturer
  • 2
    Made in
  • 1
    Additional
View:
32 products
Oxygen meter MARK® 303 T
Oxygen meter MARK® 303 T
Convenience and accuracy of measurement | Automatic temperature and barocompensation, air oxygen calibration. Measurement modes | KRK and temperature. IP65 | Compact sealed device is reliably protected from dust and moisture. Non-volatile electronic notebook | The ability to record up to 500 measurement groups in User-named folders. USB port, software included | The ability to create and manage a data archive on a PC. Graphic indicator with backlight | Indication of readings in a user-friendly format, ease of settings. Long-lasting sensor | Sensor service life of at least 10 years. Low power consumption | Up to 600 hours of continuous operation from a set of AA elements. Designed for "operational" monitoring | "Fast" sensor – the measurement time is no more than 3 minutes. Illumination for work in darkened rooms. Record measurements at the touch of a button. Self-diagnosis | Additional guarantee of correct operation of the device
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
pH-metrMARK® 902 / MARK® 902A
pH-metrMARK® 902 / MARK® 902A
Measurement of the activity of hydrogen ions (pH, pH25), EMF and temperature of aqueous media. Control of water-chemical regimes at thermal and nuclear power facilities. pH control of aqueous media in technological processes.Two channels | Freely programmable measurement ranges. The possibility of independent measurements at two points. Convenience and accuracy of measurement, minimum maintenance | Automatic thermal compensation. Calibration according to standard buffer solutions with their automatic determination. "Active" sensor unit | The digital communication channel of the sensor with the converter unit is up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. MODBUS RTU exchange protocol. Programmable setpoints with a "dry contact" type output. Durable aluminum housing IP65 | The device is reliably protected from dust and moisture. Graphic indicator with backlight | Convenient data presentation format and ease of settings
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
pH meter MARK-903
pH meter MARK-903
Measurement of the activity of hydrogen ions (pH), ORP, EMF and temperature of aqueous media. Laboratory and "field" measurements in various industries and national economy. 24-month warranty for deliveries across the Russian Federation (the electrode system is guaranteed by the manufacturer IP65 The compact sealed device is reliably protected from dust and moisture Convenience and accuracy of measurement Automatic temperature compensation Automatic recognition of buffer solutions Self-diagnosis Non-volatile electronic notebook Ability to record up to 500 measurement groups in User-named folders USB port, software included Ability to create and manage a data archive on a PC Graphic indicator with backlight Indication of readings in a user-friendly format. Ease of settings. Protective cover Convenience during transportation and "field" measurements Low power consumption Up to 600 hours of continuous operation from a set of AA type elements
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
MARK-409 Dissolved Oxygen Analyzer
MARK-409 Dissolved Oxygen Analyzer
Measurement of dissolved oxygen concentration and temperature of aqueous media, including deaerated ones. Continuous monitoring of water-chemical regimes at thermal and nuclear power facilities. Two channels Freely programmable measurement ranges. The possibility of independent measurements at two points. Convenience and accuracy of measurement, minimum maintenance Automatic temperature and barocompensation. Automatic air oxygen calibration. Long-lasting sensor The service life of the sensor is at least 10 years. The possibility of placing the converter unit at a remote distance from the sampling point Up to 100 meters. Communication with external devices Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port, MODBUS RTU exchange protocol. Programmable setpoints with a "dry contact" type output. Durable IP65 aluminum housing The device is reliably protected from dust and moisture. Graphic indicator with backlight Convenient data presentation format and ease of settings
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
pH Analyzer MARK® 9010
pH Analyzer MARK® 9010
Measurement of the activity of hydrogen ions (pH, pH25) of "ultrapure" waters (including water with a reduced electrical conductivity of 0.055 microns /cm) and alkaline waters containing ammonia or amines. Measurement of electrical conductivity (UEP, UEP25), temperature of aqueous media. Control of water-chemical regimes at energy facilities. A new patented measurement method that does not require calibration. The absence of elements that degrade in "ultrapure" water. Convenience and accuracy of measurement | Automatic thermal compensation. Freely programmable measurement ranges. Measurement of conductivity in the range up to 30 microns/cm. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. MODBUS RTU exchange protocol. Relay of "dry" contacts (6 pcs.) with programmable functions. Durable aluminum housing IP65 | The device is reliably protected from dust and moisture. A single protective box that combines the secondary converter and the hydraulic part. Intelligent data processing algorithms. 5.7" graphic touchscreen display, 65535 colors, resolution 640*480 pixels.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
Oxygen meter MARK® 302 M
Oxygen meter MARK® 302 M
The sensor is designed specifically for BOD measurement according to the PNF F method 14.1:2:3:4.123-97. Convenience and accuracy of measurement | Automatic temperature and barocompensation. Automatic air oxygen calibration. Three measurement modes | KRK, mg/dm3. KRK, % saturation. Temperature, °C. Easy calibration by air | Minimum maintenance | Replacement of the membrane no more than once a year. Storage of the sensor in the air. Long-lasting sensor | The service life of the sensor is at least 10 years. High contrast LCD indicator | Low power consumption | Up to 2000 hours of continuous operation from a set of AA type elements.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
Na-meter MARK® 1002
Na-meter MARK® 1002
Measurement of the activity of sodium ions (CNa) and the temperature of aqueous media. Control of parameters of water-chemical regimes at thermal and nuclear power facilities.Two channels | Freely programmable measurement ranges. The possibility of independent measurements at two points of CNa or pNa, temperature. Convenience and accuracy of measurement, minimum maintenance | Measurements from 0.01 CNa. The typical error is 6%. Long intergrading interval (up to 6 months). Automatic thermal compensation. Automatic dosing device of the alkalizing reagent. No capacity with KCl. Calibration by one solution | If necessary, three-point calibration is possible. "Active" sensor unit | The digital communication channel of the sensor with the converter unit is up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. MODBUS RTU exchange protocol. Programmable settings of the "dry" contact type.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
MARK® 509 hydrogen meter
MARK® 509 hydrogen meter
Measurement of the concentration of dissolved hydrogen (CRV), including "ultra-low", and the temperature of aqueous media. Continuous monitoring of parameters of water-chemical regimes at thermal and nuclear power facilities. Two channels | Freely programmable measurement ranges. The possibility of independent measurements at two points. Convenience and accuracy of measurement, minimum maintenance | Automatic temperature and barocompensation. Long-lasting, highly stable sensor | The service life of the sensor is at least 10 years. The possibility of placing the converter unit at a remote distance | from the sampling point Up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. MODBUS RTU exchange protocol. Programmable setpoints with a "dry contact" type output. Durable aluminum housing IP65 | The device is reliably protected from dust and moisture. Graphic indicator with backlight | Convenient data presentation format and ease of settings
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
MARK-2010
MARK-2010
Portable device for periodic measurement of the volume fraction of oxygen in various gases (hydrogen, natural gas, nitrogen, argon, helium, etc.). Mainly used for monitoring oxygen in the cooling circuit of generators, electrolysis plants, gas pipelines of boilers, monitoring the air of the working area. The warranty is 24 months for deliveries across the Russian Federation. High-precision measurement of oxygen microconcentrations Unique, patent-protected sensor design Exceptional selectivity to oxygen molecules Insensitivity to humidity, carbon dioxide, oil vapor Stable operation in a gas environment of any composition Ease of operation Automatic temperature and barocompensation The duration of measurements is 2-3 minutes Atmospheric air calibration Routine maintenance - no more than 1 time per year Built-in flow stimulator for forced sample delivery High contrast LED indicator IP54 housing case Protection from dust and moisture Built-in long-lasting battery At least 1000 charge/discharge cycles Carrying strap
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
MARK-603
MARK-603
Measurement of electrical conductivity (UEP, UEP25), equivalent salinity and temperature of water and aqueous solutions, including deionized and "ultrapure". Operational control of water-chemical regimes at thermal power facilities. Control of electrical conductivity of water for laboratory analysis of 1, 2 degrees of purity according to GOST 52501-2005. 24-month warranty for deliveries across the Russian Federation Double automatic temperature compensation (ATC) Allows high-precision measurements of the conductivity of "ultrapure" water Selection of the coefficient of thermal compensation at the request of the User Stainless steel flow-immersion sensor Does not require calibration. The sensor design ensures the stability of the permanent cell Electronic notebook Ability to record up to 500 measurement groups in User-named folders Self-diagnosis Ion exchange column with sample current switch IP65 The compact sealed device is reliably protected from dust and moisture USB port, software included Graphic indicator with backlight Low power consumption Up to 600 hours of continuous operation from a set of AA type elements
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
pH meter MARK-904
pH meter MARK-904
Measurement of the activity of hydrogen ions (pH, pH25), EMF and temperature of aqueous media. Laboratory measurements in various industries and national economy. 24-month warranty for deliveries across the Russian Federation Convenience and accuracy of measurement Automatic temperature compensation. Automatic recognition of buffer solutions. Self-diagnosis Non-volatile electronic notebook Ability to record up to 500 measurement groups in named The user of the folder. USB port, software included The ability to create and manage a data archive on a PC. Graphic indicator with backlight Indication of readings in a user-friendly format. Ease of settings.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
MARK-409T Dissolved Oxygen Analyzer
MARK-409T Dissolved Oxygen Analyzer
Measurement of dissolved oxygen concentration and temperature of aqueous media, including deaerated ones.Convenience and accuracy of measurement | The measurement error is ±(0.001 + 0.035 *A) mg/dm3, (A is the measured value). The ability to work on small flows (from 25 ml / min). Routine maintenance 1 time per year. Highly stable sensor | High reaction speed. Sealed heavy-duty hydrophobic membrane. Increased mechanical strength of the structure. Two channels | Freely programmable measurement ranges. The possibility of independent measurements at two points. The possibility of placing the converter unit at a remote distance from the sampling point | Up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. MODBUS RTU exchange protocol. Hydropanel GP 409 T | The possibility of placing the measuring complex on a single panel. The supply lines are stainless steel. Routine maintenance and calibration of the sensor – without interrupting the flow. Continuous monitoring of water-chemical regimes at thermal and nuclear power facilities.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod