NPP Himelektronika

NPP Himelektronika

38 products
View:
Telephone number:
Address:
Russia, Moscow, 1 building.24
Address:
Russia, Moscow, 1 building.24
  • Selected: 0
    Applying
  • Selected: 0
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • 2
    Applying
  • 8
    Names
  • 1
    Manufacturer
  • 1
    Made in
  • 3
    Additional
View:
38 products
Device "Aquarius-M"
Device "Aquarius-M"
from 210 000 ₽
It is intended for obtaining analytical purity in laboratory conditions from distilled water, used for HPLC, electrophoresis, preparation of solutions, chromatographic samples, refueling of electrolysis generators of hydrogen/oxygen and other purposes. Technical specifications The specific resistance of the received water is not less than 17.5 MOmhsm Productivity is not less than 1 l/hour Metal ion content is not more than: Fe, Pb, Ni, Co 5 mcG/l Zn 0,5 mcG/l Cd, Cu, Mn 0,1 mcG/l The content of ammonium ions is not more than 100 mcG/l The number of bacteria is not more than 5 CFU/ml Operating time of replaceable cartridges (total volume of purified water) is not less than 300 liters Volume of refilled distilled water is 1 l Overall dimensions are 210x590x455 mm The mass of the filled device is not more than 15 kg Working conditions: ambient temperature from +15 to +35 °C Power supply from single-phase AC 220 V, 50 Hz Power consumption is not more than 50 VA
Produced in: Moscow
Pure Hydrogen Generator GVCH-16M1
Pure Hydrogen Generator GVCH-16M1
from 216 000 ₽
The characteristics of the device are similar to the GVCH-12M1 model. The difference is the generator capacity of 16 liters /hour. Technical specifications Purity of hydrogen in terms of dry gas is about 99.9999% The concentration of water vapor at 20 ° C and 1 atm is not more than 5 ppm In the output pressure stabilization mode The range of the specified output pressure of hydrogen is from 1.5 to 6.1 ati Stability of the output pressure of hydrogen is not worse than ± 0.02 ati Maximum hydrogen capacity reduced to normal conditions is 16 l/h The time of setting the operating mode, with the output turned off is no more than 30 min In the performance stabilization mode: The range of the specified hydrogen performance is from 0 to 16 l/h Maximum developed pressure in performance mode is 5.0 ati Volume of distilled water to be poured is 1.0 l Distilled water consumption is no more than 0.025 l/hour, Water consumption is 1.6 g/l of hydrogen The average life of a replaceable deionization filter cartridge (at maximum performance and single-shift operation) is at least 1 year Average power consumption: in stationary mode is no more than 200 VA maximum (at startup) is no more than 250 VA Overall dimensions of the generator, (width x depth x height) are not more than 230x470x450 mm The mass of the generator is not more than 16 kg Operating conditions: ambient temperature, °C, from +10 to +35 powered by single-phase AC voltage, V, 220 (+10 -15)% and frequency, Hz, 50 ± 1 The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Pure nitrogen generator GCHA-18-K
Pure nitrogen generator GCHA-18-K
from 396 000 ₽
The characteristics of the device are similar to the GCHA-18 model; the difference is that the oil–free compressor built into the GCHA-18-K generator provides complete autonomy of the device. The warranty for the device is 18 months, for the built-in compressor-12 months from the date of sale.
Produced in: Moscow
Pure Hydrogen Generator GVCH-16A
Pure Hydrogen Generator GVCH-16A
from 325 200 ₽
The characteristics of the device are similar to the GVCH-12A model. The difference is the generator capacity of 16 liters /hour. Technical specifications Purity of hydrogen in terms of dry gas is about 99.9999% Concentration of water vapor at 20OC and 1atm is not more than 5 ppm Total hydrogen capacity, reduced to normal conditions is not less than 16 l/h The range of the specified output pressure of hydrogen is from 3.0 to 6.1 ati Stability of the output pressure of hydrogen is not worse than ± 0.02 ati The time of setting the operating mode, with the output turned off is no more than 30 min Volume of distilled water to be poured is 1.0 l Distilled water consumption is no more than 0.03 l/hour Water consumption is 1.6 g/l of hydrogen The average life of the replaceable cartridge of the deionization filter (at maximum performance and single-shift operation) is not less than 1 year Average power consumption: in stationary mode is no more than 220 VA maximum (at startup) is no more than 250 VA Overall dimensions of the generator, (width x depth x height) are not more than 230x470x450 mm The mass of the generator is not more than 17 kg Operating conditions: ambient temperature is from +10 to +35 °C powered by single-phase AC voltage, V, 220 (+10 -15)% and frequency, Hz, 50 +1 The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Pure nitrogen generator GCHA-180
Pure nitrogen generator GCHA-180
from 448 800 ₽
GCHA-180 nitrogen generators are designed to produce in laboratory conditions nitrogen of the highest purity that is used to power analytical instruments, boxes with an inert atmosphere. Technical specifications The grade of nitrogen produced according to GOST 9293-74 is high purity, grade I Volume fraction of nitrogen is not less than, % by volume (including impurities of inert gases — argon, neon, helium) 99.999 Volume fraction of oxygen is not more than, % vol. 0.0005 (5 ppm) Volume fraction of water vapor is not more than, % vol. 0.0007 (7 ppm) Volume fraction of hydrogen is not more than, % vol. (ppm) 0.0002 (2 ppm) The volume fraction of the sum of carbon-containing compounds in terms of methane is not more than, % vol. (ppm)* (with a methane content in the supply air of not more than 4 ppm) 0.0003 (3 ppm) Maximum nitrogen capacity is not less than, l/h, 180 (3.0 l/min) Nominal nitrogen output pressure (with the throttle open) is 4 ati The time of setting the operating mode for single-shift operation is no more than 45 min Nominal inlet air pressure is 6 ati Maximum allowable inlet air pressure is 8 ati Minimum inlet air pressure is 5.5 ati Compressed air consumption, at nominal inlet pressure and maximum flow rate is no more than, l/h, 4200 (60 l/min) Power consumption is not more than, VA, 100 Overall dimensions, (width x depth x height) are not more than, mm, 230x580x680; Weight is not more than, kg 36 Working conditions: ambient temperature, C°, from +10 to +35 Electric power supply from single-phase AC mains voltage, V, 220± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Nitrogen generator GA-600
Nitrogen generator GA-600
from 444 000 ₽
The nitrogen generator is designed to create an inert atmosphere, fill low-pressure tanks, "wash" test tubes with inert gas and other applications that require a large, by laboratory standards, nitrogen consumption with reduced requirements for its purity. Technical specifications Volume fraction of nitrogen is not less than 99.5 % by volume (including impurities of inert gases — argon, neon, helium) Volume fraction of oxygen is not more than 0.5 % vol. Volume fraction of water vapor is not more than 0.002 % vol. (20 ppm) Maximum nitrogen capacity: at an inlet air pressure of 8 ati is at least 600 l/h (10 l/min) at an inlet air pressure of 6 ati is at least 480 l/h (8 l/min) The time of setting the operating mode for single-shift operation is no more than 30 min Nominal inlet air pressure is 8 ati Maximum allowable inlet air pressure is 8.5 ati Minimum inlet air pressure is 7.5 ati Compressed air consumption, at nominal inlet pressure and maximum flow rate is no more than 3600 l/hour (60 l/min) Overall dimensions, (width x depth x height) are not more than 230x580x680 mm Weight is not more than 32 kg Working conditions: ambient temperature, C°, is from +10 to +35 Electric power supply from single-phase AC mains voltage, V, 220± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Generator of pure nitrogen and zero air GCHA-18D-60V
Generator of pure nitrogen and zero air GCHA-18D-60V
from 330 000 ₽
It is intended for obtaining nitrogen of the highest purity and zero air in laboratory conditions. The warranty period of operation of the generator is 18 months from the date of sale by the manufacturer. Technical specifications The grade of nitrogen produced according to GOST 9293-74 is high purity, grade I Volume fraction of nitrogen is not less than 99,999 % vol. (including impurities of inert gases — argon, neon, helium) Volume fraction of oxygen is not more than, 0.0005 % vol. (5 ppm) Volume fraction of water vapor in nitrogen is not more than 0.0007 % vol. (7 ppm) The volume fraction of hydrogen in nitrogen is not detected Volume fraction of the sum of carbon-containing compounds in nitrogen in terms of methane is not more than 0.00001 % vol.(0.1 ppm) Maximum nitrogen capacity is not less than 18 liters/hour (300 ml/min) Nominal output pressure of nitrogen is 4 ati Volume fraction of water vapor in the generated air is not more than 0.0007 % vol. (7 ppm) The volume fraction of the amount of hydrocarbons in the produced air in terms of methane is not more than 0.00001 % vol. (0.1 ppm), (with a concentration of methane in the supply air not more than 5 ppm) Maximum air capacity is not less than 60 liters/hour (1000 ml/min) Nominal output air pressure is not less than 3.5 ati The time of setting the operating mode for single-shift work is no more than 45 min Nominal inlet air pressure is 6 ati Maximum allowable inlet air pressure is 7 ati Minimum inlet air pressure is not less than 5.5 ati Compressed air consumption, at nominal inlet pressure is no more than 480 l/h (8 l/min) Power consumption is not more than 150 VA Overall dimensions, (width x depth x height) are not more than 230x425x510 mm Weight is not more than 25 kg Operating conditions: ambient temperature, ° C, from +10 to +35 electric power supply from a single-phase AC network with voltage, V, 220 ± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator meets the electrical safety requirements of class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Pure nitrogen generator GCHA-120
Pure nitrogen generator GCHA-120
from 382 800 ₽
GCHA-120 nitrogen generators are designed to produce in laboratory conditions nitrogen of the highest purity that is used to power analytical instruments, boxes with an inert atmosphere. Technical specifications The grade of nitrogen produced according to GOST 9293-74 is high purity, grade I Volume fraction of nitrogen is not less than % by volume (including impurities of inert gases — argon, neon, helium) 99.999 Volume fraction of oxygen is not more than, % vol. 0.0005 (5 ppm) Volume fraction of water vapor is not more than, % vol. 0.0007 (7 ppm) Volume fraction of hydrogen is not more than, % vol. (ppm) 0.0002 (2 ppm) The volume fraction of the sum of carbon-containing compounds in terms of methane is not more than, % vol. (ppm)* (with a methane content in the supply air of not more than 4 ppm) 0.0003 (3 ppm) Maximum nitrogen capacity is at least 120 (2.0 l/min), l/h Nominal nitrogen output pressure (with the throttle open) is 4 ati The time of setting the operating mode for single-shift operation is no more than 45 min Nominal inlet air pressure is 6 ati Maximum allowable inlet air pressure is 8 ati Minimum inlet air pressure is 5.5 ati Compressed air consumption, at nominal inlet pressure and maximum flow rate is no more than, l/h, 3600 (60 l/min) Power consumption is not more than, VA, 100 Overall dimensions, (width x depth x height) are not more than, mm, 230x580x680; Weight is not more than, kg 32 Working conditions: ambient temperature, C°, from +10 to +35 Electric power supply from single-phase AC mains voltage, V, 220± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Pure nitrogen generator GCHA-60
Pure nitrogen generator GCHA-60
from 342 000 ₽
The pure nitrogen generator (hereinafter referred to as the generator) is designed to produce in laboratory conditions nitrogen of the highest purity that is used to power analytical instruments (chromatographs, including those equipped with an electronic capture detector, express analyzers of hydrogen content in metals, organic carbon concentration meters, sample evaporators, etc.). Technical specifications The grade of nitrogen produced according to GOST 9293-74 is high purity, grade I Volume fraction of nitrogen is not less than, % by volume (including impurities of inert gases — argon, neon, helium) 99.999 Volume fraction of oxygen is not more than, % vol. 0.0005 (5 ppm) Volume fraction of water vapor is not more than, % vol. 0.0007 (7 ppm) The volume fraction of the sum of carbon-containing compounds in terms of methane is not more than, % vol. (ppm) * (with a methane content in the supply air of not more than 4 ppm) 0.0003 (3 ppm) Maximum nitrogen capacity is not less than 60 l/hour (1.0 l/min) Nominal output pressure of nitrogen with the throttle open) is 4 ati The time of setting the operating mode for single-shift operation is no more than 45 min. Nominal inlet air pressure is 6 ati Maximum allowable inlet air pressure is 8 ati Minimum inlet air pressure is 5.5 ati Compressed air consumption, at nominal inlet pressure and maximum flow rate is no more than, l/hour, 1800 (30 l/min) Power consumption is not more than, VA, 100 Overall dimensions, (width x depth x height) are not more than, mm, 220x540x670 Weight is not more than, kg 32 Working conditions: ambient temperature, C°, from +10 to +35 Electric power supply from single-phase AC mains voltage, V, 220± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Pure Air Generator GCHV-2.0-3.5
Pure Air Generator GCHV-2.0-3.5
from 200 400 ₽
The generators are designed to supply analytically clean air to flame ionization detectors and gas analyzers. They are available in two versions depending on performance and output pressure. Thanks to the presence of a system of catalytic purification of air from hydrocarbons, the generator can significantly improve the accuracy and sensitivity of chromatographic analyses. Technical specifications Air capacity reduced to normal conditions is not less than 2.0 l/min Outlet air pressure is 355 ± 5% kPa (3.5 ati) Output pressure stability at constant flow rate is not worse than ± 10 kPa The stability of the output pressure when the flow rate changes from 0.3 to the maximum value is not worse than ± 10 kPa Output concentration of hydrocarbons is not more than 0.1 ppm Water vapor concentration at 20°C and 100 kPa is no more than 10 ppm Ready time after switching on is no more than 30 min Power consumption is not more than 200 VA Overall dimensions of the generator (width x depth x height) are not more than 230x425x510 mm The mass of the generator is not more than 18 kg Working conditions: ambient temperature, °C from +10 to +35 relative humidity of the ambient air, % 80 power supply from a single-phase network: AC voltage, 220 ± 10% and frequency, Hz 50 ± 1
Produced in: Moscow
Dry Air Compressor KSV-6/450
Dry Air Compressor KSV-6/450
from 195 600 ₽
The oil-free compressor is designed to supply air to laboratory nitrogen and oxygen generators, purge optical systems of laboratory devices with dry air, etc. A feature of the device is the presence of a built-in automatic regeneration system of the air drying filter, which frees the user from routine maintenance. Small dimensions, low noise level, lack of maintenance work allow the compressor to be placed in the laboratory room and make working with it easy. Technical specifications Rated output, reduced to normal conditions is 7.0 l/min Maximum output, reduced to normal conditions is 9.0 l/min The range of the set output pressure is from 1.0 to 6.0 ati Output pressure stability at constant flow rate is not worse than ± 0.2 ati Stability of the output pressure when the flow rate changes from 0.5 to the maximum value is not worse than ± 0.4 ati The dew point of the outlet air at an ambient temperature of 20 ° C and rated capacity is not higher than minus 30 ° C The dew point of the outlet air at an ambient temperature of 20 ° C and maximum performance is not higher than minus 15 ° C Volume of the built-in receiver is 6 l The noise level of the device is not more than 50 db Ready time after switching on is no more than 10 min Power consumption is not more than 600 VA Overall dimensions of the device (width x depth x height) are not more than 230x580x530 mm Weight of the device is not more than 27 kg Working conditions: ambient temperature, °C from +10 to +35 relative humidity of the ambient air, % 80 power supply from a single-phase network: AC voltage, 220 ± 10% and frequency, Hz 50 ± 1
Produced in: Moscow
Pure Hydrogen Generator GVCH-9M
Pure Hydrogen Generator GVCH-9M
from 158 400 ₽
The characteristics of the device are similar to the GVCH-12D model; the difference is in the absence of a reactor to remove traces of oxygen and the performance, respectively, is 9 / hour (150 ml/min). Optionally equipped with a reactor for using hydrogen as a carrier gas. Technical specifications Purity of hydrogen in terms of dry gas is about 99.998% Concentration of water vapor at 20 OC and 1atm is no more than 5 ppm In the output pressure stabilization mode The range of the specified output pressure of hydrogen is from 1.5 to 6.1 ati Stability of the output pressure of hydrogen is not worse than ± 0.02 ati Maximum hydrogen capacity reduced to normal conditions is 9 l/h The time of setting the operating mode, with the output turned off is no more than 15 min In the performance stabilization mode: The range of the specified hydrogen performance is from 0 to 9 l/h Maximum developed pressure in performance mode is 5.0 ati Volume of distilled water to be poured is 1.0 l Distilled water consumption is no more than 0.015 l/hour Water consumption is 1.6 g/l of hydrogen The average life of a replaceable deionization filter cartridge (at maximum performance and single-shift operation) is at least 1 year Average power consumption: in stationary mode is no more than 80 VA maximum (at startup) is no more than 100 VA Overall dimensions of the generator, (width x depth x height) are not more than 230x470x450 mm The mass of the generator is not more than 15 kg Operating conditions: ambient temperature, °C, from +10 to +35 powered by single-phase AC voltage, V, 220 (+10 -15)% and frequency, Hz, 50 +1 The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow