Aquarius Deionizer
Aquarius Deionizer
It is intended for obtaining in laboratory conditions from distilled especially pure (deionized) water used for the preparation of solutions, chromatographic samples, refueling of electrolytic hydrogen/oxygen generators and other purposes. Technical specifications The specific conductivity of the resulting water is not more than 0.20* mkSxcm Capacity is at least 6* l/h Metal ion content is not more than: Fe, Pb, Ni, Co 5* mcG/l Zn, Cd, Cu, Mn 1*m cG/l The optical density of ammonia relative to bidistilled water is no more, D - 0.01* Operating time of the replaceable cassette (total volume of purified water) is not less than 700 liters. Volume of refilled distilled water is 1 l Overall dimensions are 180x420x430mm  The weight of the filled device is no more than 9 kg Operating conditions: ambient temperature from +10 ° C to +35 ° C Power supply from single-phase AC 220 V., 50 Hz The power consumption is not more than 20 VA.
Produced in: Moscow
Pure nitrogen generator GCHA-21
Pure nitrogen generator GCHA-21
from 252 000 ₽
Designed for laboratory production of nitrogen of the highest purity that are used to power analytical instruments (chromatographs, express analyzers of hydrogen content in metals, organic carbon concentration meters, sample evaporators, etc.), boxes with an inert atmosphere.
Produced in: Moscow
Pure Hydrogen Generator GVCH-12A
Pure Hydrogen Generator GVCH-12A
from 297 600 ₽
The device is equipped with an automatic regeneration system of fine filters, which reduces the maintenance of the device to a minimum. In terms of the totality of technical characteristics and ease of operation, it has no equal among similar laboratory hydrogen generators. The hydrogen capacity is 12 liters/hour (200 ml/min). Technical specifications Purity of hydrogen in terms of dry gas is about 99.9999% Concentration of water vapor at 20OC and 1 atm is not more than 5ppm Total hydrogen capacity, reduced to normal conditions is not less than 12 l/h The range of the specified output pressure of hydrogen is from 3.0 to 6.1 ati Stability of the output pressure of hydrogen is not worse than ± 0.02 ati The time of setting the operating mode, with the output turned off is no more than 30 min Volume of distilled water to be poured is 1.0 l Distilled water consumption is no more 0.02 l/hour Water consumption is 1.6 g/l of hydrogen The average life of the replaceable cartridge of the deionization filter (at maximum performance and single-shift operation) is not less than 1 year Average power consumption: in stationary mode is no more than 180 VA maximum (at startup) is no more than 220 VA Overall dimensions of the generator, (width x depth x height) is not more than 230x470x450 mm The mass of the generator is not more than 16 kg Operating conditions: ambient temperature, °C, from +10 to +35 powered by single-phase AC voltage 220 V(+10 -15)% and frequency 50 +1 Hz The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Generator of Pure Nitrogen and Zero Air GCHA-21D-72V
Generator of Pure Nitrogen and Zero Air GCHA-21D-72V
from 450 000 ₽
It is intended for obtaining nitrogen of the highest purity and zero air in laboratory conditions. The warranty period of operation of the generator is 18 months from the date of sale by the manufacturer. Technical specifications The grade of nitrogen produced according to GOST 9293-74 is high purity, grade I Volume fraction of nitrogen is not less than 99,999 % vol. (including impurities of inert gases — argon, neon, helium) Volume fraction of oxygen is not more than 0.0005 % vol. (5 ppm) Volume fraction of water vapor in nitrogen is not more than 0.0007 % vol. (7 ppm) The volume fraction of hydrogen in nitrogen is not detected Volume fraction of the sum of carbon-containing compounds in nitrogen in terms of methane is not more than 0.00001 % vol. (0.1 ppm) Maximum nitrogen capacity is not less than 21 liters/hour (350 ml/min) Nominal output pressure of nitrogen is 4 ati Volume fraction of water vapor in the generated air is not more than 0.0007 % vol.(7 ppm) The volume fraction of the amount of hydrocarbons in the produced air in terms of methane is not more than 0.00001 % vol. (0.1 ppm), (with a concentration of methane in the supply air not more than 5 ppm) Maximum air capacity is not less than 72 liters/hour (1200 ml/min) Nominal output air pressure is not less than 3.5 ati The time of setting the operating mode for single-shift operation is no more than 45 min Nominal inlet air pressure is 6.0 ati Maximum allowable inlet air pressure is 7 ati Minimum inlet air pressure is not less than 5.5 ati Compressed air consumption, at nominal inlet pressure is no more than 480 l/h (8 l/min) Power consumption is not more than 150 VA Overall dimensions, (width x depth x height) are not more than 230x525x510 mm Weight is not more than 28 kg Operating conditions: ambient temperature, ° C, from +10 to +35 electric power supply from a single-phase AC network with voltage, V, 220 ± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator meets the electrical safety requirements of class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Nitrogen generator GA-600
Nitrogen generator GA-600
from 426 000 ₽
The nitrogen generator is designed to create an inert atmosphere, fill low-pressure tanks, "wash" test tubes with inert gas and other applications that require a large, by laboratory standards, nitrogen consumption with reduced requirements for its purity. Technical specifications Volume fraction of nitrogen is not less than 99.5 % by volume (including impurities of inert gases — argon, neon, helium) Volume fraction of oxygen is not more than 0.5 % vol. Volume fraction of water vapor is not more than 0.002 % vol. (20 ppm) Maximum nitrogen capacity: at an inlet air pressure of 8 ati is at least 600 l/h (10 l/min) at an inlet air pressure of 6 ati is at least 480 l/h (8 l/min) The time of setting the operating mode for single-shift operation is no more than 30 min Nominal inlet air pressure is 8 ati Maximum allowable inlet air pressure is 8.5 ati Minimum inlet air pressure is 7.5 ati Compressed air consumption, at nominal inlet pressure and maximum flow rate is no more than 3600 l/hour (60 l/min) Overall dimensions, (width x depth x height) are not more than 230x580x680 mm Weight is not more than 32 kg Working conditions: ambient temperature, C°, is from +10 to +35 Electric power supply from single-phase AC mains voltage, V, 220± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Device "Aquarius-M"
Device "Aquarius-M"
from 210 000 ₽
It is intended for obtaining analytical purity in laboratory conditions from distilled water, used for HPLC, electrophoresis, preparation of solutions, chromatographic samples, refueling of electrolysis generators of hydrogen/oxygen and other purposes. Technical specifications The specific resistance of the received water is not less than 17.5 MOmhsm Productivity is not less than 1 l/hour Metal ion content is not more than: Fe, Pb, Ni, Co 5 mcG/l Zn 0,5 mcG/l Cd, Cu, Mn 0,1 mcG/l The content of ammonium ions is not more than 100 mcG/l The number of bacteria is not more than 5 CFU/ml Operating time of replaceable cartridges (total volume of purified water) is not less than 300 liters Volume of refilled distilled water is 1 l Overall dimensions are 210x590x455 mm The mass of the filled device is not more than 15 kg Working conditions: ambient temperature from +15 to +35 °C Power supply from single-phase AC 220 V, 50 Hz Power consumption is not more than 50 VA
Produced in: Moscow
Pure Hydrogen Generator GVCH-12M1
Pure Hydrogen Generator GVCH-12M1
from 186 000 ₽
The characteristics of the device are similar to the GVCH-12A model; the difference is in the absence of an autoregeneration system for fine gas filters. Technical specifications Purity of hydrogen in terms of dry gas is about 99.9999% The concentration of water vapor at 20 ° C and 1 atm is not more than 5 ppm In the output pressure stabilization mode The range of the specified output pressure of hydrogen is from 1.5 to 6.1 ati Stability of the output pressure of hydrogen is not worse than ± 0.02 ati Maximum hydrogen capacity reduced to normal conditions is 12 l/h The time of setting the operating mode, with the output turned off is no more than 30 min In the performance stabilization mode: The range of the specified hydrogen performance is from 0 to 12 l/h Maximum developed pressure in performance mode is 5.0 ati Volume of distilled water to be poured is 1.0 l Distilled water consumption is no more than 0.02 l/hour Water consumption is 1.6 g/l of hydrogen The average life of a replaceable deionization filter cartridge (at maximum performance and single-shift operation) is at least 1 year Average power consumption: in stationary mode is no more than 150 VA maximum (at startup) is no more than 200 VA Overall dimensions of the generator, (width x depth x height) are not more than 230x470x450 mm The mass of the generator is not more than 15 kg Operating conditions: ambient temperature, °C, from +10 to +35 powered by single-phase AC voltage, V, 220 (+10 -15)% and frequency, Hz, 50 ± 1 The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Nitrogen Generator GA-400-K
Nitrogen Generator GA-400-K
The nitrogen generator is designed to create an inert atmosphere, fill low-pressure tanks, "wash" test tubes with inert gas and other applications that require a large, by laboratory standards, nitrogen consumption with reduced requirements for its purity. The warranty for the device is 18 months, for the built–in compressor - 12 months from the date of sale. Technical specifications Volume fraction of nitrogen is not less than 99.5 % vol. (including impurities of inert gases — argon, neon, helium) Volume fraction of oxygen is not more than 0.5% vol. (ppm) Volume fraction of water vapor is not more than 0.002 % vol. (ppm) (20 ppm) Maximum nitrogen capacity is not less than 400 l/hour (6.66 l/min) Nitrogen outlet pressure is 4±0.2 ati The time of setting the operating mode for single-shift operation is no more than 45 min Noise level generated by the compressor is no more than 60 db Power consumption is not more than 800 VA Overall dimensions, (width x depth x height) are not more than 360x680x550 mm Weight is not more than 46 kg Operating conditions: ambient air temperature, oS from +10 to +35 electric power supply from single-phase AC voltage, 220 ± 5% frequency, Hz 50 ± 1 Average full service life is at least 6 years The generator for electrical safety meets the requirements of GOST 12.2.025-76. class 1, type
Produced in: Moscow
Pure Nitrogen Generator GCHA-18D-K
Pure Nitrogen Generator GCHA-18D-K
from 408 000 ₽
The characteristics of the device are similar to the GCHA-18D model; The difference is that the oil–free compressor built into the GCHA-18D-K generator provides complete autonomy of the device. The warranty for the device is 18 months, for the built-in compressor - 12 months from the date of sale. Technical specifications The grade of nitrogen produced according to GOST 9293-74 is high purity, grade I The volume fraction of nitrogen is not less than, % vol. (including impurities of inert gases: argon, neon, helium) 99,999 The volume fraction of oxygen is not more than, % vol. (ppm) 0.0005 (5 ppm) The volume fraction of water vapor is not more than, % vol. (ppm) 0.0007 (7 ppm) The volume fraction of hydrogen is not more than, % vol. (ppm) 0.0002 (2 ppm) The volume fraction of the sum of carbon-containing compounds in terms of methane is not more than, % vol. (ppm) (with a concentration of methane in the supply air not more than 5 ppm)* 0.00001 (0.1 ppm) Maximum nitrogen capacity is not less than 18 liters/hour (300 ml/min) Nominal output pressure of nitrogen is 4 ati The time of setting the operating mode for single-shift operation is no more than, min, * 45 Noise level generated by the compressor is no more than 45 dB Power consumption is not more than 300 VA Overall dimensions, (width x depth x height) are not more than, mm 230x470x510 Weight, not more than, kg 25 Working conditions: Ambient temperature, °C from +10 to +35 Electric power supply from a single-phase AC network with a voltage of 220 ± 10% and a frequency of 50 ± 1 Hz Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Pure nitrogen generator GCHA-120
Pure nitrogen generator GCHA-120
from 382 800 ₽
GCHA-120 nitrogen generators are designed to produce in laboratory conditions nitrogen of the highest purity that is used to power analytical instruments, boxes with an inert atmosphere. Technical specifications The grade of nitrogen produced according to GOST 9293-74 is high purity, grade I Volume fraction of nitrogen is not less than % by volume (including impurities of inert gases — argon, neon, helium) 99.999 Volume fraction of oxygen is not more than, % vol. 0.0005 (5 ppm) Volume fraction of water vapor is not more than, % vol. 0.0007 (7 ppm) Volume fraction of hydrogen is not more than, % vol. (ppm) 0.0002 (2 ppm) The volume fraction of the sum of carbon-containing compounds in terms of methane is not more than, % vol. (ppm)* (with a methane content in the supply air of not more than 4 ppm) 0.0003 (3 ppm) Maximum nitrogen capacity is at least 120 (2.0 l/min), l/h Nominal nitrogen output pressure (with the throttle open) is 4 ati The time of setting the operating mode for single-shift operation is no more than 45 min Nominal inlet air pressure is 6 ati Maximum allowable inlet air pressure is 8 ati Minimum inlet air pressure is 5.5 ati Compressed air consumption, at nominal inlet pressure and maximum flow rate is no more than, l/h, 3600 (60 l/min) Power consumption is not more than, VA, 100 Overall dimensions, (width x depth x height) are not more than, mm, 230x580x680; Weight is not more than, kg 32 Working conditions: ambient temperature, C°, from +10 to +35 Electric power supply from single-phase AC mains voltage, V, 220± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Pure Hydrogen Generator GVCH-36A
Pure Hydrogen Generator GVCH-36A
from 438 000 ₽
The characteristics of the device are similar to the model GVCH-12A (GVCH-25A). The difference is the generator capacity of 36 liters / hour, the purity of the produced hydrogen is lower (99.998% vol). Technical specifications Purity of hydrogen in terms of dry gas is about 99.998 % Concentration of water vapor at 20OC and 3 atm is no more than 7 ppm Total hydrogen capacity reduced to normal conditions is 36 l/h The range of the specified output pressure of hydrogen is from 3.0 to 6.1 ati Stability of the output pressure of hydrogen is not worse than ± 0.03 ati The time of setting the operating mode, with the output turned off is no more than 30 min Volume of distilled water to be poured is 1.0 l Distilled water consumption is no more 0.06 l/hour Water consumption is 1.6 g/l of hydrogen The average life of a replaceable deionization filter cartridge (at maximum performance and single-shift operation) is at least 0.5 years Average pump life (for single-shift operation) is at least 0.5 years Power consumption: in stationary mode is no more than 250 VA maximum (at startup) is no more than 280 VA Overall dimensions of the generator, (width x depth x height) are not more than 230x470x450 mm The mass of the generator is not more than 18 kg Operating conditions: ambient temperature, °C, from +10 to +35 powered by single-phase AC voltage, V, 220 (+10 -15)% and frequency, Hz, 50 +1 The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Pure hydrogen generator GVCH-25A
Pure hydrogen generator GVCH-25A
from 392 400 ₽
The characteristics of the device are similar to the GVCH-12A model. The difference is the generator capacity of 25 liters / hour, the purity of the produced hydrogen is lower (99.9995% vol). Technical specifications Purity of hydrogen in terms of dry gas шы about 99.9995% Concentration of water vapor at 20OC and 3 atm is no more than 7 ppm Total hydrogen capacity reduced to normal conditions is 25 l/h The range of the specified output pressure of hydrogen is from 3.0 to 6.1 ati Stability of the output pressure of hydrogen is not worse than ± 0.02 ati The time of setting the operating mode, with the output turned off is no more than 30 min Volume of distilled water to be poured is 1.0 l Distilled water consumption is no more than 0.04 l/h Water consumption is 1.6 g/l of hydrogen The average life of a replaceable deionization filter cartridge (at maximum performance and single-shift operation) is at least 0.5 years Average pump life (for single-shift operation) is at least 0.5 years Power consumption: in stationary mode is no more than 250 VA maximum (at startup) is no more than 280 VA Overall dimensions of the generator, (width x depth x height) is not more than 230x470x450 mm The mass of the generator is. not more than 18 kg Operating conditions: ambient temperature, °C, from +10 to +35 powered by single-phase AC voltage, V, 220 (+10 -15)% and frequency, Hz, 50 +1 The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76