Accessories

360 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 20
    Applying
    Loading...
  • 93
    Names
    Loading...
  • 37
    Manufacturer
    Loading...
  • 24
    Made in
    Loading...
  • 26
    Additional
    Loading...
View:
360 products
CRYO basket-VT-06-K
CRYO basket-VT-06-K
It is designed to accommodate thermostatically controlled objects in the inner bath of the liquid low-temperature thermostat CRYO VT 06. The height-adjustable bottom allows objects to be immersed in the coolant to the required depth. Internal dimensions 300x200x120 mm Weight 2.7 kg
Produced in: Tomsk
Heating element for a 2.4 kW 220 V distiller
Heating element for a 2.4 kW 220 V distiller
from 1 860 ₽
The tank for the 2.4 kW aquadistillator is made of stainless steel.
Livam
Belgorod
Produced in: Belgorod
Basket VT14-K-PZH25
Basket VT14-K-PZH25
The height-adjustable bottom allows the tanks to be immersed in the coolant to the required depth. Internal dimensions 150x90 mm Weight 1 kg
Produced in: Tomsk
PS-78 (waves.)
PS-78 (waves.)
Strobe converters are used as input devices of radio measuring equipment: amplifasometers, frequency meters, spectrum analyzers, circuit analyzers, etc.; in systems of synchronization and frequency stabilization of microwave generators, heterodynes, frequency synthesizers. Basic properties: Wide frequency range; Minimal losses and uneven conversion; High "decoupling" of channels; Large dynamic range of input signals; Harsh operating conditions Operating conditions Operating temperature range from minus 10 to 50 °C; Relative humidity up to 98% at a temperature of 25 ° C. Technical specifications Frequency range: • Microwave signal, GHz 37.5-78.33 • heterodyne, GHz 2.0-6.0 • IF, MHz 0-1000 Conversion losses *>, 30-40 dB by the 20th garm. The power level of the heterodyne, dBm 20-22 Connector type: • Microwave signal input P-waveguide with transitions to 5,2x2,6 and 3,6x1,8 mm • 1HR heterodyne input • IF output two woofer inputs
Produced in: Moscow
COOLING LPG SV
COOLING LPG SV
Device for dosing of liquefied gases is made for insertion of liquids and liquefied gases under the pressure of 7 MPa into the chromatograph. Injection of liquefied gas without de-gassing is provided by cooling of valve, and it greatly reduces inaccuracy of the analysis results. Cooling temperature is set by temperature regulator. Visual control of absence of de-gassing and flow control of the analyzed fluid is provided. Dose volume is form 0.2 to 2 mcl. Valve of VICI production or dispenser valve of our own production is used directly as a sample-valve.
Produced in: Yoshkar-Ola, Mari El
Flame Ionization (PID) for chromatograph
Flame Ionization (PID) for chromatograph
The most common, universal detector that is suitable for the analysis of a wide range of organic compounds. The sensitivity depends mainly on the number of carbon atoms. In combination with a methanator, it allows the analysis of carbon oxides at the level of 0.1 Rt. The level of fluctuation noise is up to 50 MV, the maximum signal is up to 2500 V. Technical characteristic: 1.2*10712 gs/s for hydrocarbons
Produced in: Yoshkar-Ola, Mari El
Tripod for placing butyrometers in cryostats and thermostats LA-205
Tripod for placing butyrometers in cryostats and thermostats LA-205
Number of sockets, pcs 14 Hole diameter, mm 25 Immersion depth, mm 200 Overall dimensions (WxDxH), mm 235x80x215
LOIP
Saint Petersburg
Produced in: Saint Petersburg
A set of CRYO-T devices-05-01- K
A set of CRYO-T devices-05-01- K
It is used in determining the low-temperature characteristics of petroleum products and organic chemical products in accordance with the State Standard 5066 (Method B) and GOST 18995.5.
Produced in: Tomsk
External temperature sensor LA-501
External temperature sensor LA-501
Designed to measure the temperature in the external circuit of the LOIP LT-200 and LT-400 series thermostats. An external temperature sensor is connected to the temperature control unit and directly monitors the temperature in the external circuit of the thermostat, which significantly increases the accuracy of temperature maintenance. Temperature range, °C from -50 to +250 Cable length, m 1.4
LOIP
Saint Petersburg
Produced in: Saint Petersburg