Silicone hose with thermal insulation and an internal diameter of 18 mm is used to connect the CRYO-VT-07 thermostat or A600 circulation cooler to external consumers.
Silicone hose with thermal insulation and an internal diameter of 10 mm is used to connect circulating coolers and thermostats of the CRYO-W series to external consumers or is used as a jumper hose
Silicone hose with an inner diameter of 8 mm is used to connect circulation coolers A160 and A300 with thermostats of the W series or to external consumers.
For thermostats operating at high temperatures and filled with an ICP coolant, a viton hose with a cross section of 10/14 should be used as a jumper hose.
Silicone hose with an inner diameter of 10 mm is used to connect the thermostats of the VTk series with external consumers or is used as a jumper hose.
Silicone hose with thermal insulation and an internal diameter of 8 mm is used to connect the A160 and A300 circulation coolers with the W series thermostats or to external consumers.
A viton hose with an internal diameter of 10 mm is used to connect the VTi CRYO-VT series thermostats to external consumers or as a jumper hose. We recommend it for use with PMS heat carriers
Bellows hose with thermal insulation and an internal diameter of 10 mm is used to connect thermostats of the VTi CRYO-VT series to external consumers or as a jumper hose. We recommend it for use with PMS heat carriers at high temperatures.
Four workstations with a diameter of 140 mm and a height-adjustable bottom allow the sample containers to be immersed in the coolant to the required depth.
Overall dimensions 515x310x215 mm
Weight 3.5 kg
It is designed for thermostating glasses, flasks and evaporating cups with samples in the laboratory bath LB33 and LB33-Sh.
Overall dimensions 310x250x210 mm
Weight 2.0 kg
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
Designed for devices KKK–2, KKK–3 and their modifications when operating in the spectral range from 315 to 980 nm. Chemically resistant to acids (except hydrofluoric acid) and dilute alkalis.
The holder with flat steel springs allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 16 to 20 mm.
It is designed for calibration thermostats THERMOTEST-100 and THERMOTEST-300.
It is used in determining the low-temperature characteristics of petroleum products and organic chemical products in accordance with the State Standard 5066 (Method B) and GOST 18995.5.