It is designed for simultaneous polishing of four copper plates measuring 75×12.5×2 mm used in determining the corrosive effect of fuels in accordance with GOST ISO 2160, GOST 32329, GOST 6321, GOST 2917 and ASTM D130.
A set of devices is used to determine the oil content in oil paraffins in accordance with the State Standard 9090 and is intended for placement in a liquid bath BNTI 05 04.
It is used for recording transmission spectra of medium–sized and arbitrary-shaped solid samples - polymer films of various thicknesses, optical parts, semiconductor wafers, large crystals, etc.
• Thanks to quick-release nuts, it provides convenient fastening of samples
The stopper holder made of Teflon allows you to mount securely the temperature sensor of LTA electronic thermometers with a diameter of 4 mm in the 14/23-inch laboratory glassware.
The stopper holder is made of Teflon. It allows you to mount securely the temperature sensor of the LT 300 or LT electronic thermometers in 14/23-sized laboratory glassware.
If you are going to use an electronic thermometer LT 300, LT or LTA not in the laboratory, but in the non-laboratory condiditions, this durable case with a lid will protect the sensor from damage.
The size of the case is determined by the length of of your thermometer.
Allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 9 to 16 mm.
The design of the holder eliminates damage to glass thermometers.
It is designed for calibration thermostats THERMOTEST-100 and THERMOTEST-300.
The holder with flat steel springs allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 9 to 16 mm.
It is designed for calibration thermostats THERMOTEST-100 and THERMOTEST-300.
It is designed to accommodate six cylinders for hydrometers with a diameter of up to 54 mm in thermostats VT-ro-01, VT-ro-02 or CRYO-VT-ro-03. A basket with a height-adjustable bottom allows the cylinders to be immersed in the coolant to the required depth.
Number of jobs 6
Weight 1.1 kg
It is used in determining the flow temperature of petroleum products in accordance with GOST 20287 (method A).
For testing, additional sets of devices BNTI 05 04 K and BNTI 05 04 3K are required
A set of devices is used to determine the oil content in oil paraffins in accordance with the State Standard 9090 and is intended for placement in a liquid bath BNTI 05 04.
Designed to measure the temperature in the external circuit of the LOIP LT-200 and LT-400 series thermostats. An external temperature sensor is connected to the temperature control unit and directly monitors the temperature in the external circuit of the thermostat, which significantly increases the accuracy of temperature maintenance.
Temperature range, °C from -50 to +250
Cable length, m 1.4
ConFlat (CF) standard connections are used еo ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
It is used to connect LT-300 thermometers to a personal computer via a USB interface. This is a "native" device for the ThermoChart program.
The use of this adapter does not require the installation of additional drivers because it uses the HID driver built into the operating system to exchange data.
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
The ISO-KF connection (DIN 28 403 and ISO 2861) allows quick installation and replacement of components in vacuum systems. The connection consists of two symmetrical ISO-KF flanges (1), a centering ring with an O-ring seal (2) and a quick-release clamp (3). High-vacuum ISO-KF connections can be mounted without using a tool by simply turning the nut of the quick-release clamp.