It is the holder with spring clip for working viscometers of types VPJ 1, VPJ 2, VPJ 4, residence permit, Cannon Fenske Routine, Cannon FenskeOpaque, Ubbelohde, BS/IP/RF.
The stopper holder made of Teflon allows you to mount securely the temperature sensor of LTA electronic thermometers with a diameter of 4 mm in the 14/23-inch laboratory glassware.
Allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 3 to 9 mm.
The design of the holder eliminates damage to glass thermometers.
It is designed for calibration thermostats THERMOTEST-100 and THERMOTEST-300.
The holder with flat steel springs allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 16 to 20 mm.
It is designed for calibration thermostats THERMOTEST-100 and THERMOTEST-300.
It is intended for placing vessels with samples in the working baths of the BNTI 05 04 bath when determining the low-temperature properties of petroleum products, if appropriate test vessels are available.
Suitable for placing vessels with samples for the State Standard 20287 (Method A), EN 23015 or ASTM D97.
It is used for determining the low-temperature characteristics of petroleum products in accordance with the State Standard 20287 (Method A), EN 23015 and ASTM D97
It is designed for simultaneous polishing of four copper plates measuring 75×12.5×2 mm used in determining the corrosive effect of fuels in accordance with GOST ISO 2160, GOST 32329, GOST 6321, GOST 2917 and ASTM D130.
The stopper holder is made of Teflon. It allows you to mount securely the temperature sensor of the LT 300 or LT electronic thermometers in 14/23-sized laboratory glassware.
It is designed to be placed in a liquid thermostat CRYO T 05 01 and is used to determine the turbidity temperature and the beginning of crystallization of motor fuel in accordance with GOST 5066 (method B).
For testing, an additional set of CRYO T 05 01 K devices is required.
Designed for devices of the SF, Minigem, Specord series when operating in the spectral range from 260 to 2500 nm. Chemically resistant to acids (except hydrofluoric acid) and dilute alkalis.
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
It is the stand for thermostats W R 01 and W R 03.
It provides convenience when measuring, allowing you to install pressure gauges at eye level.
Overall dimensions 400x625x420 mm
Allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 3 to 9 mm.
The design of the holder eliminates damage to glass thermometers.
It is designed for calibration thermostats THERMOTEST-100 and THERMOTEST-300.
The stand provides convenience when taking measurements, allowing you to set the thermometers at eye level.
It is designed for calibration thermostat THERMOTEST 300.
Overall dimensions 400x625x420 mm
The stand provides convenience when taking measurements, allowing you to set the thermometers at eye level.
Designed for calibration thermostat THERMOTEST-100.
Overall dimensions 400x625x490 mm
The stainless steel stand is designed for installation and storage of pressure gauges MTIf 100, MTIf 160 and MTIf 400 in the process of determining the absolute vapor pressure of volatile crude oil and volatile non-viscous petroleum products.
Overall dimensions 170x95x105 mm
Weight 0.5 kg