The holder with flat steel springs allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 16 to 20 mm.
It is designed for THERMOTEST 05 and THERMOTEST-05-1 thermostats.
Allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 3 to 9 mm.
The design of the holder eliminates damage to glass thermometers.
It is designed for calibration thermostats THERMOTEST-100 and THERMOTEST-300.
It is used in determining the density of petroleum products, resins, plasticizers and other chemical products by hydrometers in stainless steel cylinders with a height of 300 mm and internal diameters of 60.5 and 73 mm.
It is used in determining the low-temperature characteristics of petroleum products and organic chemical products in accordance with the State Standard 5066 (Method B) and GOST 18995.5.
It is intended for placement in the BF bath and is used in determining the mass fraction of paraffins in oil in accordance with the method A of the State Standard 11851.
It is intended for placing vessels with samples in the working baths of the BNTI 05 04 bath when determining the low-temperature properties of petroleum products, if appropriate test vessels are available.
Suitable for placing vessels with samples for the State Standard 20287 (Method A), EN 23015 or ASTM D97.
The stopper holder made of Teflon allows you to mount securely the temperature sensor of LTA electronic thermometers with a diameter of 4 mm in the 14/23-inch laboratory glassware.
It is used for determining the low-temperature characteristics of petroleum products in accordance with the State Standard 20287 (Method A), EN 23015 and ASTM D97
The holder with flat steel springs allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 3 to 9 mm.
It is designed for THERMOTEST 05 and THERMOTEST-05-1 thermostats.
A set of devices is used to determine the oil content in oil paraffins in accordance with the State Standard 9090 and is intended for placement in a liquid bath BNTI 05 04.
It is designed for simultaneous polishing of four copper plates measuring 75×12.5×2 mm used in determining the corrosive effect of fuels in accordance with GOST ISO 2160, GOST 32329, GOST 6321, GOST 2917 and ASTM D130.
It is used for recording transmission spectra of medium–sized and arbitrary-shaped solid samples - polymer films of various thicknesses, optical parts, semiconductor wafers, large crystals, etc.
• Thanks to quick-release nuts, it provides convenient fastening of samples
The stopper holder made of Teflon allows you to mount securely the temperature sensor of LTA electronic thermometers with a diameter of 4 mm in the 14/23-inch laboratory glassware.
It is used to connect TDS thermometers and MASTER thermostats equipped with an RS 485 interface to a personal computer via a USB interface.
The use of this adapter does not require the installation of additional drivers because it uses the HID driver built into the operating system to exchange data.
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
ConFlat (CF) standard connections are used еo ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
The holder with flat steel springs allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 16 to 20 mm.
It is designed for THERMOTEST 05 and THERMOTEST-05-1 thermostats.
Allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 3 to 9 mm.
The design of the holder eliminates damage to glass thermometers.
It is designed for calibration thermostats THERMOTEST-100 and THERMOTEST-300.
A basket with a height-adjustable bottom allows objects to be immersed in the coolant to the required depth.
Overall dimensions 305x305x390 mm
Internal dimensions 260x250mm
Weight 3.1 kg
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.