It is used in determining the flow temperature of petroleum products in accordance with GOST 20287 (method A).
For testing, additional sets of devices BNTI 05 04 K and BNTI 05 04 3K are required
It is the holder with spring clip for working viscometers of types VPJ 1, VPJ 2, VPJ 4, residence permit, Cannon Fenske Routine, Cannon FenskeOpaque, Ubbelohde, BS/IP/RF.
It is used for determining the low-temperature characteristics of petroleum products in accordance with the State Standard 20287 (Method A), EN 23015 and ASTM D97
If you are going to use an electronic thermometer LT 300, LT or LTA not in the laboratory, but in the non-laboratory condiditions, this durable case with a lid will protect the sensor from damage.
The size of the case is determined by the length of of your thermometer.
Allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 3 to 9 mm.
The design of the holder eliminates damage to glass thermometers.
It is designed for calibration thermostats THERMOTEST-100 and THERMOTEST-300.
It is used in determining the low-temperature characteristics of petroleum products and organic chemical products in accordance with the State Standard 5066 (Method B) and GOST 18995.5.
It is intended for placement in the BF bath and is used in determining the mass fraction of paraffins in oil in accordance with the method A of the State Standard 11851.
The stopper holder made of Teflon allows you to mount securely the temperature sensor of LTA electronic thermometers with a diameter of 4 mm in the 14/23-inch laboratory glassware.
It is used for recording transmission spectra of medium–sized and arbitrary-shaped solid samples - polymer films of various thicknesses, optical parts, semiconductor wafers, large crystals, etc.
• Thanks to quick-release nuts, it provides convenient fastening of samples
The stainless steel stand is designed for installation and storage of pressure gauges MTIf 100, MTIf 160 and MTIf 400 in the process of determining the absolute vapor pressure of volatile crude oil and volatile non-viscous petroleum products.
Overall dimensions 170x95x105 mm
Weight 0.5 kg
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
It is used for determining the low-temperature characteristics of petroleum products in accordance with the State Standard 20287 (Method A), EN 23015 and ASTM D97
It is the stand for thermostats W R 01 and W R 03.
It provides convenience when measuring, allowing you to install pressure gauges at eye level.
Overall dimensions 400x625x420 mm