It is used in determining the low-temperature characteristics of petroleum products and organic chemical products in accordance with the State Standard 5066 (Method B) and GOST 18995.5.
The stopper holder is made of Teflon. It allows you to mount securely the temperature sensor of the LT 300 or LT electronic thermometers in 14/23-sized laboratory glassware.
It is used in determining the flow temperature of petroleum products in accordance with GOST 20287 (method A).
For testing, additional sets of devices BNTI 05 04 K and BNTI 05 04 3K are required
It is used in determining the density of petroleum products, resins, plasticizers and other chemical products by hydrometers in stainless steel cylinders with a height of 300 mm and internal diameters of 60.5 and 73 mm.
It is used for determining the low-temperature characteristics of petroleum products in accordance with the State Standard 20287 (Method A), EN 23015 and ASTM D97
It is designed to be placed in a liquid thermostat CRYO T 05 01 and is used to determine the turbidity temperature and the beginning of crystallization of motor fuel in accordance with GOST 5066 (method B).
For testing, an additional set of CRYO T 05 01 K devices is required.
Allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 3 to 9 mm.
The design of the holder eliminates damage to glass thermometers.
It is designed for calibration thermostats THERMOTEST-100 and THERMOTEST-300.
It is used for recording transmission spectra of medium–sized and arbitrary-shaped solid samples - polymer films of various thicknesses, optical parts, semiconductor wafers, large crystals, etc.
• Thanks to quick-release nuts, it provides convenient fastening of samples
The stopper holder made of Teflon allows you to mount securely the temperature sensor of LTA electronic thermometers with a diameter of 4 mm in the 14/23-inch laboratory glassware.
It is designed to accommodate six cylinders for hydrometers with a diameter of up to 54 mm in thermostats VT-ro-01, VT-ro-02 or CRYO-VT-ro-03. A basket with a height-adjustable bottom allows the cylinders to be immersed in the coolant to the required depth.
Number of jobs 6
Weight 1.1 kg
It is designed for thermostating glasses, flasks and evaporating cups with samples in the laboratory bath LB33 and LB33-Sh.
Overall dimensions 310x250x210 mm
Weight 2.0 kg
The clamp connection (DIN 28 404 and ISO 1609) allows connecting components from DN 63 to DN 630 in any position, on any fixed flange regardless of the location of the bolt holes.
It is designed to improve short-term temperature stability during verification and calibration of electronic thermometers LT 300 (except LT-300-F), LT and ExT-01/1 in calibration thermostats TERMOTEST 100, TERMOTEST-100-40, TERMOTEST 05 and TERMOTEST-05-1.
It is designed to accommodate thermostatically controlled objects in the inner bath of the T40 liquid thermostat.
A basket with a height-adjustable bottom allows objects to be immersed in the coolant to the required depth.
Overall dimensions 305x305x390 mm
Internal dimensions 260x250mm
Weight 2.8 kg
ConFlat (CF) standard connections are used еo ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
Four workstations with a diameter of 140 mm and a height-adjustable bottom allow the sample containers to be immersed in the coolant to the required depth.
Overall dimensions 515x310x215 mm
Weight 3.5 kg