Equipment

2226 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 387
    Item names
    Loading...
  • 125
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 99
    Additional
    Loading...
View:
2226 products
Laboratory drying cabinet SNOL-F-25/500-I2
Laboratory drying cabinet SNOL-F-25/500-I2
from 165 061 ₽
The laboratory drying cabinet SNOL-F-25/500-I2 is designed for thermal testing, aging, as well as drying, tempering and other types of heat treatment of various materials in an air environment at temperatures up to 500 ° C with natural or forced air convection in stationary conditions.
Produced in: Tula
Liquid low-temperature thermostat CRYO-VIS-T-03
Liquid low-temperature thermostat CRYO-VIS-T-03
Operating temperature range -30...+50 °C Two places for glass viscometers. Stability and uniformity of temperature in the working bath is not worse than ± 0.01 ° C. Bath volume 12 l Overall dimensions 440x710x620 mm The open part of the bath is 165x85 mm Bath depth 300 mm The size of the viewing window is 130x270 mm Weight 55 kg Power consumption 3.5 kW
Produced in: Tomsk
PL-01 Heating plate
PL-01 Heating plate
Laboratory heating plate for heat treatment at temperature control and heating time. It can be equipped with an additional function for setting the heating speed. The heating platform is made of duralumin. The size of the heating surface: 284x220 mm. Heating temperature: 40-400 °C. It can be equipped with a tray for a sand bath.
Produced in: Tomsk
BSA-400 Laboratory bath
BSA-400 Laboratory bath
It is designed for thermostating 4 tripods with Florinsky tubes during serological studies. Each tripod is designed for the installation of 100 Florinsky tubes with a size of Ø14×60 mm. The bath can be used in laboratories of hygiene and epidemiology centers, veterinary medical examination, medical laboratories and other laboratories conducting serological studies. Bath volume 23 l Overall dimensions 650x615x210 mm The open part of the bath is 480x480 mm Bath depth 100 mm Weight 23 kg Power consumption 2.0 kW
Produced in: Tomsk
UCHX2-37
UCHX2-37
Basic properties: Wide frequency range; Sufficiently large output power; High level of suppression of side harmonics of the input signal; Low value of phase noise; Relatively simple technical solutions: - synchronization and frequency stabilization, - stabilization and adjustment of the output power level, - implementation of amplitude and frequency modulation modes; Do not require external bias diodes. Operating conditions: Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical characteristics Input/output frequency range, GHz 12,93-18,75 / 25,86-37,5 Losses (max.), dB 13 Input power level, dBm 15-21 Unevenness of output power (Rvh. = 20 dBm), dB ± 1.5 The level of parasitic harmonics of the input signal at the output (min.), dBn 20 Output VSWR (max.) 2.0 Connector type: • Input Coax. 3.5/1.5 mm (socket) • Output Waveguide 7.2x3.4 mm Overall dimensions, mm 29x24x24 Weight, g 60
Produced in: Moscow
2NVR-5DM1 Rotary vane vacuum pump
2NVR-5DM1 Rotary vane vacuum pump
The 2NVR-5DM1 rotary vane vacuum pump is manufactured in the climatic version of UHL 4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, but to be used at ambient temperature and pumped medium 283 K to 308 K (+10˚C to +35˚C). It meets the requirements of technical specifications TU 3648-006-00218526-2002. It is designed and manufactured taking into account the requirements of GOST R 52615-2006. Electricity grid must meet the requrimemnts of GOST 32144-2013
Produced in: Kazan
Automatic apparatus ATK-LAB-12 for determining the temperature of crystallization (freezing) by laser method
Automatic apparatus ATK-LAB-12 for determining the temperature of crystallization (freezing) by laser method
The parameters of accuracy, convergence and reproducibility are equivalent and correlate with the result obtained in accordance with manual methods ASTM D2386, GOST R 52332-2005, GOST 5066-91, ISO 3013, IP 16 The device is designed taking into account all the requirements of the standards for testing and is equipped with a built-in cooling system that allows the test cell to cool down to -100 ° C, without requiring external cooling. • Sample temperature detection range -100...25 °C Accuracy of determination of sample temperature ± 0.1 °C The temperature range of the test chamber is -100...30 °C The volume of the analyzed sample is 10 ± 2 ml Power consumption from the mains 220, not more than 250 watts USB, LAN interface Overall dimensions (WxHxD), not more than 250x450x360 mm Weight, not more than 12 kg
LOIP
Saint Petersburg
Produced in: Saint Petersburg
MARK-5010 Hydrogen Purity Analyzer
MARK-5010 Hydrogen Purity Analyzer
High-precision measurements of hydrogen concentration in the range of 95-100% Monitoring of the operation of electrolyzers, control of hydrogen purity in the processes of hydrogen cooling of generators, in the technological processes of chemical, petrochemical, metallurgical and other industries 24 months warranty for deliveries across the Russian Federation A new patented measurement method The device does not require calibration Selectivity of measurement Direct method of measuring molecular hydrogen Insensitivity to humidity, carbon dioxide, oil vapor Measurement time 3-5 min Simple, intuitive interface Minimum maintenance Self-diagnosis Routine maintenance no more than 1 time per year Long-lasting, highly stable sensor The service life of the sensor is at least 10 years Color touch screen
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod, Moscow
IR Laser Module KLM-D980-x-5 980nm
IR Laser Module KLM-D980-x-5 980nm
from 4 314 ₽
Laser modules of the KLM-D980-x-5 series are optimal sources of coherent radiation for the construction of control and automation systems, alignment and marking devices, for scientific and medical purposes.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
CRYO-VT-11 Low-temperature liquid thermostat
CRYO-VT-11 Low-temperature liquid thermostat
It is designed to maintain the set temperature of the coolant circulating in the internal bath of the thermostat and in the connected external consumers. Feed pump for external closed-type thermostating systems. Cooling capacity 300 W at +20 °C. An internal bath with a volume of 17 liters and a depth of 250 mm. Operating temperature range -30...+100 °C. Overall dimensions 400x690x585 mm The open part of the bath is 140x190 mm Bath depth 250 mm Weight 50 kg Power consumption 3.5 kW.
Produced in: Tomsk
Copper Transceiver SFP 10/100/1000Base-T
Copper Transceiver SFP 10/100/1000Base-T
from 2 175 ₽
Receiving and transmitting modules for electrical communication lines in SFP metal cases with separate optical input/output for an RJ-45 type electrical connector to transmit the signal over two optical fibres.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
SRK‑AT2327 ALARM METER
SRK‑AT2327 ALARM METER
Building a flexible and reliable multi-channel system Independent measurements on each channel in a wide range of gamma and neutron radiation dose rates and neutron and beta particle flux densities Audiable and light alarms High reliability and self-control Software that allows you to display on the PC monitor the current radiation situation in the controlled area Data logging Backup power supply The possibility of integration with external security systems
Produced in: Belarus, Minsk