Equipment

2226 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 387
    Item names
    Loading...
  • 125
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 99
    Additional
    Loading...
View:
2226 products
Nitrogen Generator GA-400-K
Nitrogen Generator GA-400-K
The nitrogen generator is designed to create an inert atmosphere, fill low-pressure tanks, "wash" test tubes with inert gas and other applications that require a large, by laboratory standards, nitrogen consumption with reduced requirements for its purity. The warranty for the device is 18 months, for the built–in compressor - 12 months from the date of sale. Technical specifications Volume fraction of nitrogen is not less than 99.5 % vol. (including impurities of inert gases — argon, neon, helium) Volume fraction of oxygen is not more than 0.5% vol. (ppm) Volume fraction of water vapor is not more than 0.002 % vol. (ppm) (20 ppm) Maximum nitrogen capacity is not less than 400 l/hour (6.66 l/min) Nitrogen outlet pressure is 4±0.2 ati The time of setting the operating mode for single-shift operation is no more than 45 min Noise level generated by the compressor is no more than 60 db Power consumption is not more than 800 VA Overall dimensions, (width x depth x height) are not more than 360x680x550 mm Weight is not more than 46 kg Operating conditions: ambient air temperature, oS from +10 to +35 electric power supply from single-phase AC voltage, 220 ± 5% frequency, Hz 50 ± 1 Average full service life is at least 6 years The generator for electrical safety meets the requirements of GOST 12.2.025-76. class 1, type
Produced in: Moscow
MARK® 01 MK
MARK® 01 MK
Cooling, throttling, filtration and regulation of sample flow. Indication of temperature, pressure and flow of the sample. Temperature, pressure and cooling water flow indication (optional). Sample preparation for water-chemical regime monitoring devices at energy facilities. Continuous monitoring of sample parameters and data transmission via digital and current outputs. Maintaining stable sample pressure. Alarm and automatic shut-off of the sample supply in case of violation of the regime. Custom temperature and pressure settings for automatic shut -off of sample supply. Pulse line purge valve. Compact stainless steel panel 350*944 mm. One-way service. Easy-to-clean collapsible heat exchanger.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
Air Purification Units BOV-1
Air Purification Units BOV-1
from 79 200 ₽
They are designed for purification of nitrogen (BOV-1A) and air (BOV-1) from hydrocarbons Technical specifications Inlet air pressure is not more than 825 ± 5% kPa (8 ati) Output pressure control limits is from 0 to 413 kPa (from 0 to 4.0 ati) Minimum required excess of inlet pressure over outlet pressure is not less than 103 kPa(1 ati) Maximum permissible air flow is not more than 1.0 l/min Concentration of hydrocarbons at maximum flow rate in the outlet air is no more than 0.1 ppm Water vapor concentration at 20°C and 100 kPa is no more than 10 ppm Instability of the output pressure when the flow rate changes from 0 to the maximum value is not worse than ± 7 kPa Instability of the output pressure when the input pressure changes by ± 100 kPa is not worse than ± 7 Ready time after switching on at a flow rate not exceeding the maximum value is no more than 30 min Power consumption is not more than 50 VA Overall dimensions, (width x depth x height) are no more than 185x310x310 mm Weight is not more than 5.0 kg Working conditions: ambient temperature, °C, from +10 to +35 relative humidity of the ambient air, %, no more, at 35 ° C 80 electric power from a single-phase AC network with a voltage of 220 +10% -15% and a frequency of 50 ± 1 Hz
Produced in: Moscow
Vacuum Drying cabinet APU-30-6- Ah
Vacuum Drying cabinet APU-30-6- Ah
B – vacuum, Su – for drying, 30 – the volume of the working space in dm3, 6 – the maximum operating temperature divided by 100, i.e., 600 ° C, A – the furnace is equipped with an adsorber
VakETO
Mosrentgen
Produced in: Moscow
Modules SFP xPON
Modules SFP xPON
1 supp.
Optical modules SFP xPON are capable of operating at a data transfer rate of up to 2.5 Gbit/s and are used in gigabit passive optical networks.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Press PKM-12
Press PKM-12
1 supp.
It is used in the manual method of determining the content of raw gluten in wheat and wheat flour and is recommended for the specified products supplied for export. The use of the PCM - 12 press allows to exclude subjective factors affecting the result of the analysis, and to obtain more reproducible results with less manual labor. The press consists of two glass plates with a rough surface, provides a stable fixed gap between the plates. It has a stand and a handle for opening. technical specifications: Overall dimensions, mm 250x185 Thickness of glass plates, mm 10 The gap between the glass plates, mm 2,4 Weight, kg 2.7
GK EKAN
Saint Petersburg
Produced in: Saint Petersburg
Liquid thermostat VIS-T-07
Liquid thermostat VIS-T-07
Operating temperature range +15...+100 °C Six places for glass viscometers. Overflow design ensures stability and uniformity of temperature not worse than ± 0.01 °C Bath volume 35 l Number of jobs 6 Overall dimensions 575x285x620 mm The open part of the bath is 295x170 mm Bath depth 310 mm The size of the viewing window is 275x275 mm Weight 32 kg Power consumption 2.2 kW
Produced in: Tomsk
Furnace control cabinet SHUP-25-1
Furnace control cabinet SHUP-25-1
Designation SHUP-25-1 Switching power, kW 25 Automatic switch, A 50 Supply network voltage, V/Hz 380
Produced in: Tula
COMBO-SOUT (Assistant-TOTAL, METEOSCOPE-M + Black ball, VE-meter (50Hz Modification), TKA-LUX, TKA-PKM-13)
COMBO-SOUT (Assistant-TOTAL, METEOSCOPE-M + Black ball, VE-meter (50Hz Modification), TKA-LUX, TKA-PKM-13)
from 530 000 ₽
A COMBO-SOUT kit for carrying out a special assessment of working conditions in a reliable, shockproof, moisture- and dust-proof case.
Produced in: Moscow
Circulation thermostat LT-224a
Circulation thermostat LT-224a
The LOIP LT-224a modification device consists of an immersion thermostat-circulator LOIP LT-200 and a working bath with a flat removable lid. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +200 with tap water cooling °C Tvods+5 ...+200 Accuracy of temperature maintenance, °C ± 0.1 The error of setting the set temperature, no more than ° C ± 0.2 Heater power, W 2000 Pump: max. flow rate, l/min 10.5 pressure, 0.27 bar Bath volume, l 24 The working fluid is water, water-glycerin mixture, silicone oil. Open part of the bath / depth, mm 360x296/200 Overall dimensions, mm 535x335x420 Weight, kg 14.2
LOIP
Saint Petersburg
Produced in: Saint Petersburg