Equipment

2285 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 394
    Names
    Loading...
  • 124
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 91
    Additional
    Loading...
View:
2285 products
Hydraulic press GP 200-13
Hydraulic press GP 200-13
Designed for the preparation of samples in the form of compressed tablets with a diameter of up to 13 mm, consisting of the test substance in a mixture with microcrystalline potassium bromide (KBr). - the principle of operation of the press is based on the injection of pressure in the hydraulic system by swinging the lever. - to control the working pressure, the press is equipped with a pressure gauge - complete with a press, molds with a diameter of 13 mm and 3.5 mm can be used - for the study of finished samples on a Fourier spectrometer, a KBr tablet holder and D13mm substrate windows or a microfocusing attachment (for 3.5 mm tablets) is used
SIMEKS
Novosibirsk
Produced in: Novosibirsk
Smart air probe L=1000 mm SSV.1000
Smart air probe L=1000 mm SSV.1000
from 11 520 ₽
Designed to measure the temperature of various materials by direct contact of the probe with the measuring object The smart air probe L=1000 mm SSV.1000 is designed to measure the temperature of various materials by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor. Android program is installed. Operating conditions of the SZV.1000 smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the smart probe SSV.1000 Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor. Android program is installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
High-temperature smart surface probe L=300 mm SZPVV.300P with built-in flash memory
High-temperature smart surface probe L=300 mm SZPVV.300P with built-in flash memory
from 15 663 ₽
High-temperature smart surface probe L=300 mm SZPVV.The 300P with built-in flash memory is designed to measure the temperature of various materials by directly contacting the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor, Android program installed. Operating conditions of the SZPVV smart probe.300P Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the SZPVV smart probe.300P Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor, Android program installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
Consistometer ZM-1003M
Consistometer ZM-1003M
The consistometer can be used in laboratories of grouting offices, drilling departments and oil-producing associations, as well as in laboratories of research organizations engaged in the development of formulations and research of grouting cements, mixtures and solutions for cementing wells. The consistometer can be transported to the place of testing cement mortars in compliance with the rules of transportation specified in the passport of the device, while no additional calibration is required. The consistometer works in conjunction with a personal computer, as well as in offline mode under the control of a microprocessor system. The pressure is set by a manual high-pressure pump by the operator. In the dialog mode, the operator sets the parameters necessary for testing grouting solutions. The test results can be transmitted via the USB interface to a personal computer for printing, archiving or processing by user programs. Technical specifications The range of determination of consistency is from 0 to 100 units of consistency (1e.k. = 1 Bc, Bc is a unit of consistency of Burden). The limit of the permissible reduced error in determining the consistency is ± 5% of the measurement range (100 E.K. = 100 Bc). The rotational speed of the measuring frame in cement mortar is (150 ±1) rpm. The heating range of the tested solutions is from the current temperature to 200 ° C. The limit of the permissible reduced error in determining the temperature is ± 1%. The range of the tested pressure is from the current, atmospheric, to 100 MPa. The limit of the permissible reduced error in determining the pressure in the autoclave is ± 2.5%. Operating conditions: ambient temperature – from +10 to +35 ° C; relative humidity up to 65% at 20 ° C and up to 80% at 27 ° C. The electrical insulation resistance between the electrical circuits and the housing at ambient temperature (20 ± 5) ° C and relative humidity (80 ± 3)% is not less than 20 mOhm. The electrical insulation between the electrical circuits and the housing under the conditions of clause 2.7. must withstand an alternating current voltage of 1.5 kV of a sinusoidal shape with a frequency of 50 Hz. Power supply of the installation: voltage: ≈ 220 V ±10%; the frequency of the supply network is 50 Hz; power consumption, no more than - 3 kW. Overall dimensions, not more than, mm: 750x400x1000; The average service life is at least 10 years. The mass of the consistometer is no more than 145 kg.
Produced in: Krasnodar
Electromagnetic flow meter Volga EM
Electromagnetic flow meter Volga EM
from 300 000 ₽
The Volga EM electromagnetic flowmeter is designed to measure the volumetric flow rate of drinking, natural, purified and waste water in pressure and non-pressure water pipelines. The device is designed specifically for use as part of commercial metering units and meets all the requirements for measuring equipment used for financial settlements of economic entities. The flow meter can be equipped with connecting fittings that allow the measuring sensor to be installed in a water duct with a non-pressure flow mode, for example, in a sewer collector (the so-called "L-system"). Secondary converter It is available in both stationary (~220 V) and portable versions with autonomous power supply. Primary converters PP – full-pass primary converter PPM is a full–pass primary converter for low costs and installation in L-systems BP – mortise rod primary converter Pipe sizes Du, mm: 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300 mm
Produced in: Moscow
Measuring antenna P6-62
Measuring antenna P6-62
1 supp.
Technical specifications: Frequency range (300-1000) MHz SWR < 2 The limit of permissible error of the antenna coefficient, not more than ± 2.0 dB Orthogonal polarization signal level -20 dB Ambient air temperature from - 50 to + 60 Relative humidity of 95 % at + 35 ° C Overall dimensions (HxWxD) 400x145x150 mm Weight 1 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Immitance Broadband Analyzer E7-29
Immitance Broadband Analyzer E7-29
Technical specifications: Extended frequency range 50 kHz–15 MHz The basic error is ±0.2 % The level of the measuring signal is 40 mV – 1 V s.c . Offset voltage (0 – 40) V The discreteness of the operating frequency setting is 1 Hz Graphical analysis of measured values in a given frequency range USB 2.0 interface -100 C to 400 C; humidity 90% at 300 C Dimensions, weight: 270x134x320 mm, 5 kg Power supply ~230 V, 20 VA
MNIPI
Minsk
Produced in: Belarus, Minsk
Gas radiometer UDG-03D
Gas radiometer UDG-03D
Installation for continuous measurement and transmission over the information network of the value of the volumetric activity of beta-emitting gases (argon, krypton, xenon). It is used in gas-aerosol control systems at nuclear power and fuel cycle facilities. Purpose: measurement of the volumetric activity of beta-emitting gases (argon, krypton, xenon).
Doza
Zelenograd
Produced in: Moscow
50M URS special manual vacuum angle valve
50M URS special manual vacuum angle valve
The body of the 50M URS valve is of welded construction and consists of a shell, a seat, side and lower nozzles. The lower branch pipe of the 50M URS valve is connected to the vacuum system using welding. The smooth part of the stem serves as a visual indicator of the "open" or “closed” valve positions. The casing is designed to protect the valve from accidental openings, and also serves as additional protection against precipitation, sand, dust entering the inner cavity of the valve. The valve opens when the flywheel rotates counterclockwise. The valve closes when the flywheel rotates clockwise.
Produced in: Kazan