Equipment

2224 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 385
    Item names
    Loading...
  • 125
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 99
    Additional
    Loading...
View:
2224 products
Frequency comparator CHK7-51
Frequency comparator CHK7-51
Mathematical processing of the measurement makes it possible to determine and display on the indicator board the relative systematic change in frequency, the average relative value of the frequency difference, the RMS relative frequency deviation, the RMS relative two-sample frequency deviation.
NNPO im. M.V.Frunze
Nizhny Novgorod
Produced in: Nizhny Novgorod
Cryothermostat liquid FT-311-80
Cryothermostat liquid FT-311-80
Technical specifications: Operating temperature range, °C -80...+100 Accuracy of temperature maintenance, °C ± 0.1 The discreteness of the temperature display, ° C 0.1 Cooling capacity at 20°C, W 510 Pump capacity in the discharge (suction) circuit, not less than, l/min 8 Volume of working fluid, l 11 Open part of the bath/depth, mm 175x135/200 Power supply, V/Hz 220/50 Power consumption, no more than 4.4 kW Overall dimensions, mm 535x555x985 Weight without working fluid, kg 80
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Vacuum drying cabinet with automatic adjustment SNVS-40/5
Vacuum drying cabinet with automatic adjustment SNVS-40/5
for carrying out heat treatment according to pre-created programs. The presence of remote control and a number of software options allows you to use the product for long-term heat treatment modes. Vacuum drying cabinets can be used for: - gentle drying of thermo- and oxygen-sensitive substances, such as food, medicinal, cosmetic products; - complete removal of residual moisture from heat-sensitive components with a complex shape, such as components of electronic equipment, jewelry, watches and other precision mechanics; - removal of air when filling the molds with a compound, followed by solidification at a given temperature; - removing air from the product and replacing it with another necessary gas medium; - tempering, annealing or aging of metals with the appropriate processing temperature in a vacuum or protective environment; - drying of products after washing in flammable solvents (special version); - testing of devices under low pressure conditions under various temperature conditions.
Produced in: Tula
Tracing generator AG-105
Tracing generator AG-105
from 100 740 ₽
The automatic tracing pulse generator AG-105 is designed to create propagating signals (vibrations) in the routes of hidden communications with the active method of tracerouting. The device creates an alternating sinusoidal current in the studied communication (constantly or in short-term parcels) necessary to determine its location. The features of the AG-105 generator Extremely high power output and battery life, for a compact battery pack ("Type C" × 8) and such small overall dimensions. Universal power supply allows you to reach an output power of over 20 watts. With autonomous power supply, the "life cycle" depends on the quality of the "type C" batteries used. For example, with an initial output power of 7 watts in continuous generation mode, the "life cycle" is ≈ 5 hours, and with an initial output power of 15 watts in intermittent modulation mode, the "life cycle" is ≈ 25 hours (using standard new "fresh" batteries, for example, "Energizer C"). When using "ultra-high-capacity" batteries (for example, "Duracell ULTRA" or "COSMOS"), the battery life can be increased by 20-30%. When connecting an external "12V" battery (for example, a car), the operating time is determined by the capacity of this battery. When connecting an external mains power supply "15 V", the operating time is not limited. The dimensions of the portable device in the case are 216x180x105 mm, and the weight does not exceed 2 kg. These features are provided by the use of an ultra-efficient unique modification of the circuit technology for building CLASS D power amplifiers. The pulse output amplifier reaches an efficiency of 85%, which is especially important for "energy-consuming" devices with autonomous power supply.
Produced in: Kolomna, Moscow region
Circulation thermostat LT-316a
Circulation thermostat LT-316a
Technical specifications: Temperature range: without external cooling, °C Current+10 ... +150 with tap water cooling °C Tvods+5 ...+150 Accuracy of temperature maintenance, °C ± 0.1 The error of setting the set temperature, no more than ° C ± 0.2 Heater power, W 2000 Pump: max. flow rate, l/min 8,0 pressure, 0.25 bar Bath volume, l 16 Working fluid water, water-glycerin mixtures, silicone oil The open part of the bath / depth, mm 190x296/200 Overall dimensions, mm 355x335x400 Weight, kg 12.8
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Leakage detector Success AT-207
Leakage detector Success AT-207
from 99 360 ₽
The kit of the portable acoustic leakage detector "Success AT-207" is designed to detect depressurization sites of underground pipelines of heat and water supply systems located at a depth of up to 3 m in channel and channel-free laying. The search for damage sites is carried out by the acoustic method. •
Produced in: Kolomna, Moscow region
GAS PANEL
GAS PANEL
The gas distribution panel (hereinafter referred to as the panel) is designed to connect gas nodes and blocks of various analytical instruments, including chromatographs to shop gas lines. technical specifications Inlet pressure, not more than 0.8 MPa. The output pressure is from 0 to 0.4 MPa. Gas flow rate through each channel, not less than — 1000 cm3/min.
Produced in: Yoshkar-Ola, Mari El
High pressure gas flow regulator RRG-VD
High pressure gas flow regulator RRG-VD
It can be used as a primary source of carrier gas, since it is equipped with an additional gas purification system. This device is especially relevant when, for some reason, helium is not available to the consumer (for example, when working with a thermal conductivity detector - an accident). Due to the high thermal conductivity of hydrogen, TTP operates with significantly greater sensitivity than helium.
Produced in: Yoshkar-Ola, Mari El
METANATOR
METANATOR
To analyze small concentrations of carbon monoxide (CO) and carbon dioxide (CO2), instead of the usual catarometer for these gases, a more sensitive PID is used, while carbon oxides are converted into methane (CH4) using reaction chromatography. The device implementing the conversion reaction is called a methanator, i.e. a device with a special catalyst that converts CO, CO2 into methane in a hydrogen current, while the latter is either a carrier gas itself, or is blown together with the carrier gas into the methanator through a tee. The methanator provides a highly efficient conversion reaction, while the detection limit of carbon oxides reaches 0.1 ppm. technical specifications Metanation temperature — 330 °C The coefficient of metanation is not less than 95 % The effective volume of the methanator is 1 ml.
Produced in: Yoshkar-Ola, Mari El
CRYOCONCENTRATION DEVICES
CRYOCONCENTRATION DEVICES
To determine small concentrations of substances, in some cases it is impossible to do without their concentration in special traps. An example of the need for such concentration is the determination of impurities in permanent gases (Ne, He, H2, Ar, O2, N2, Kr, Xe), the concentration of impurities is less than 1 ppm. Considering that these impurities can be not only hydrocarbons, but also permanent gases themselves, the use of direct detection of impurities by a catarometer is impossible. It is also not always possible to use highly sensitive but expensive detectors (GID, EDD, etc.). TECHNICAL CHARACTERISTICS The volume of the trap is 5 ml. The volume of the Dewar vessel (serial metal thermos) is 1200 ml. The concentration temperature range is from minus 88.6 (ethane) to minus 269 °C (helium). The ability to calibrate the chromatograph from the cylinder without disturbing the gas circuit. The possibility, simultaneously with concentration, to purify the gas intended for purging the trap from impurities (in a similar trap). Overall dimensions, no more than — 290 ×470 × 615 mm. Weight, not more than — 8 kg.
Produced in: Yoshkar-Ola, Mari El
GEYSER-2A DEVICE
GEYSER-2A DEVICE
The Geyser –2A measuring and computing complex is designed to determine the dynamic characteristics and energy efficiency (caloric content) of various substances, including special products (gunpowder, explosives). The device also allows you to determine the chemical resistance of substances by the delay of the ignition time. The analysis is carried out in a given volume in the isothermal mode or in the temperature programming mode. technical specifications Operating temperature range in the reactor, from +50 to +600 ° C. The programming speed of the thermostat temperature in the operating temperature range, no more than 10 ° C. The limit of the permissible absolute error of setting the temperature of temperature control, no more than ± 2 ° C. Instability of maintaining the set temperature in the thermostat for 10 minutes, no more than ± 0.1 ° C. Sampling rate of the optical recording system, at least 25kHz The range of measurement of the ignition delay time in the isothermal mode, from 0 to 600 seconds. The measurement range of dynamic characteristics in the temperature programming mode, from 0 to 3600 sec. The continuous operation time of the device is at least 24 hours. The time for the device to enter the mode from the moment it is turned on, no more than 0.2 hours. The device is powered by AC 220V,+10/-15%,(50±1) Hz. The power consumption of the device, no more than 200 watts. The weight of the device without packaging, no more than 7 kg. Overall dimensions (width × depth × height), no more than 330×265×170 mm.
Produced in: Yoshkar-Ola, Mari El
CRYOSTATING DEVICES
CRYOSTATING DEVICES
The separation of some substances (the classic case is the separation of oxygen and argon) requires negative temperatures of the thermostat of chromatographic columns. technical specifications The lower temperature limit of the thermostat of columns with a cooling device based on an air conditioner is minus 5 °C. The error in maintaining the temperature of the thermostat of columns with a cooling device based on an air conditioner is + 0.05 °C. The power consumption of the cooling device based on an air conditioner, no more than — 640 VA. Overall dimensions of the cooling device based on the air conditioner, (width × depth × height), no more than — 620×480× 410 mm. The weight of the cooling device based on the air conditioner, no more than 32 kg. The lower limit of the temperature of the thermostat of columns with a liquid nitrogen cryoclap is minus 100 °C. The error of maintaining the temperature of the thermostat of columns with a liquid nitrogen cryoclave (in the temperature range less than 25 °C) + 0.1 °C. The power consumption of a cooling device with a liquid nitrogen cryoclave, no more than — 10 VA. Consumption of liquid nitrogen, not more than 0.1 l/h.
Produced in: Yoshkar-Ola, Mari El