Circulation thermostat LT-117a
Circulation thermostat LT-117a
The LOIP LT-117a modification device consists of an immersion thermostat-circulator LOIP LT-100 and a working bath with a flat removable lid. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +100 with tap water cooling °C Tvods+5 ...+100 Accuracy of temperature maintenance, °C ± 0.1 The error of setting the set temperature, no more than ° C ± 0.2 Heater power, W 1900 Pump: max. flow rate, l/min 7.5 pressure, 0.17 bar Bath volume, l 17 The working fluid is water, water-glycerin mixture. Open part of the bath / depth, mm 360x296/150 Overall dimensions, mm 535x335x370 Weight, kg 13
LOIP
Saint Petersburg
Produced in: Saint Petersburg
ITAN pH meter/ionometer
ITAN pH meter/ionometer
ITAN pH meter/ionometer is a representative of a new generation of universal laboratory pH meters/ionometers with a touch control panel and unique functionality. A magnetic stirrer and a tripod with a foot for installing electrodes and a thermal sensor are built into the pH meter/ionometer housing.
Produced in: Tomsk
Pure hydrogen generator GVCH-25A
Pure hydrogen generator GVCH-25A
from 402 000 ₽
The characteristics of the device are similar to the GVCH-12A model. The difference is the generator capacity of 25 liters / hour, the purity of the produced hydrogen is lower (99.9995% vol). Technical specifications Purity of hydrogen in terms of dry gas шы about 99.9995% Concentration of water vapor at 20OC and 3 atm is no more than 7 ppm Total hydrogen capacity reduced to normal conditions is 25 l/h The range of the specified output pressure of hydrogen is from 3.0 to 6.1 ati Stability of the output pressure of hydrogen is not worse than ± 0.02 ati The time of setting the operating mode, with the output turned off is no more than 30 min Volume of distilled water to be poured is 1.0 l Distilled water consumption is no more than 0.04 l/h Water consumption is 1.6 g/l of hydrogen The average life of a replaceable deionization filter cartridge (at maximum performance and single-shift operation) is at least 0.5 years Average pump life (for single-shift operation) is at least 0.5 years Power consumption: in stationary mode is no more than 250 VA maximum (at startup) is no more than 280 VA Overall dimensions of the generator, (width x depth x height) is not more than 230x470x450 mm The mass of the generator is. not more than 18 kg Operating conditions: ambient temperature, °C, from +10 to +35 powered by single-phase AC voltage, V, 220 (+10 -15)% and frequency, Hz, 50 +1 The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Circulation thermostat LT-412a
Circulation thermostat LT-412a
The LOIP LT-412a modification device consists of an immersion thermostat-circulator LOIP LT-400 and a working bath with a flat removable lid. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +200 with tap water cooling °C Tvods+5 ...+200 Accuracy of temperature maintenance, °C ± 0.01 The error of setting the set temperature, no more, °C ±0.02 Heater power, W 2200 Pump: max. flow rate, l/min 6...12 pressure, 0.4 bar Bath volume, l 12 The working fluid is water, silicone oil. The open part of the bath / depth, mm 190x296/150 Overall dimensions, mm 355x335x350 Weight, kg 11.8
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Vacuum trap of condenser type FVC-1/15C
Vacuum trap of condenser type FVC-1/15C
from 152 553 ₽
The vacuum trap of the condenser type FVC-1/15C with a capacity of 1 liter is designed for condensation and trapping of pumped vapors of epoxy resins and other substances that turn into a solid state during condensation, followed by removal of accumulated filtrate by washing with solvents or mechanical cleaning of a replaceable cartridge.
Produced in: Tula
DOSIMETER‑RADIOMETER MKS‑AT1117M (WITH DETECTION UNIT BDPS‑02)
DOSIMETER‑RADIOMETER MKS‑AT1117M (WITH DETECTION UNIT BDPS‑02)
General monitoring of contamination of various objects with radioactive substances in the counting rate mode, with the possibility of separate measurement of the alpha particle flux density and beta particle flux density, as well as the gamma radiation dose rate A wide range of measurements The possibility of using an extension rod
Produced in: Belarus, Minsk
Modular liquid cooling unit VCHV-10
Modular liquid cooling unit VCHV-10
from 253 905 ₽
Designation VCHV-10 Cooling capacity at Two.water= +15C, Tcond=+45C, Current.cp.=+30C, kW 10 Required pump capacity, m3/h 2,2 Pressure loss in the heat exchanger, kRa 40
Produced in: Tula
Cable Finder Success KBI-211
Cable Finder Success KBI-211
from 48 600 ₽
An accessible tracer without a display with an audible indication in the operator's headphones. Extremely easy to use and in a compact, lightweight case. Purpose of the cable finder Success KBI-211 • – Search for live electrical cable lines. • – Search for places where the pipeline and cable intersect. • – Determination of the occurrence of underground utilities at a depth of up to 6 m. Features of the AP-004 receiver • – Analog traceroute receiver. • – Audio indication in the operator's headphones, the real sound is 50 Hz. • – Frost-resistant, working at temperatures up to -30 °C. • – Lightweight, compact housing.
Produced in: Kolomna, Moscow region
Explosion-proof vacuum electric furnace START-25
Explosion-proof vacuum electric furnace START-25
Vacuum resistance furnaces are necessary for heating products before pressure treatment, for sintering, degassing, quenching, annealing, soldering and chemical-technological processes. Such furnaces among all the variety of thermal equipment are considered the most environmentally friendly – heat treatment is carried out at t up to +2500 ° C in a purified vacuum. Under certain conditions, vacuum furnaces are used to work with neutral gases. The outer part of the furnace is made of stainless steel and is cooled by liquid. The inner part of the working chamber, where the heat treatment of materials is carried out, is made of an alloy of molybdenum and tungsten. The components are characterized by a low inertia force, reduced gas separation. The settings are available on the control panel, where the instruments, automatic and manual control switches are located. At every enterprise of the electronic industry, nuclear power, an explosion-proof vacuum resistance furnace is needed. The same applies to areas where various products undergo heat treatment at the stage of production and preparation for use.
Produced in: Tula
Furnace for heating in a protective environment CHO (3)-6/11
Furnace for heating in a protective environment CHO (3)-6/11
from 1 420 750 ₽
Designation SNO(H)-6/11 Power, kW, no more than 8 Supply network voltage, V 380 Frequency, Hz 50
Produced in: Tula
VL-220M comparator scales
VL-220M comparator scales
from 274 990 ₽
Technical specifications NIP, g82/220 Discreteness, g0,00001/0,0001 Self-calibration Diameter of the scale bowl, mm80 The smallest weighing limit, g0,001 The price of the calibration scale division, mg1 The limits of permissible error in the weighing intervals during verification, mgot 0.001g to 50g incl. ± 0.5; sv. 50g to 200g incl. ± 1.0; sv. 200g to 220g incl. ± 1.5 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * from 1mg to 10mg ± 0.2; from 10mg to 82g ± 0.1; sv. 82g ± 0.3 The setting time, seconds, no more - fast mode - 8/3; - standard mode - 10/6 Overall dimensions of the scales (LxWxH), mm356x220x338 7 years warranty Weight of the scales, kg, not more than 7.6 The weight adjustment is built-in
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Automatic Rapid Analysis device for turbidity/solidification temperature of petroleum products TPZ-LAB-12
Automatic Rapid Analysis device for turbidity/solidification temperature of petroleum products TPZ-LAB-12
TPZ-LAB-12 belongs to the latest generation of equipment of JSC "LOIP". The device is designed taking into account all the requirements of the standards for testing. A unique feature of TPZ-LAB-12 is a built–in cooling unit capable of cooling the test cell to -85 °C without the use of external cooling systems. The device automatically sets and maintains the temperature of the cooling bath, conducts tests to determine the temperature of turbidity and solidification, creates and stores test reports in memory. Technical specifications: The volume of the analyzed sample is 4.5 ml Temperature range of the test cell -85...+51°C Accuracy of temperature maintenance ± 0.5 °C Maintaining the temperature of the cooling bath Integrated cooling system Built-in memory of at least 1000 protocols Color LCD display with touch screen Supply voltage 220 V Power consumption 250 W Overall dimensions 315x470x405 mm Weight 15 kg
LOIP
Saint Petersburg
Produced in: Saint Petersburg