Equipment

2321 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 396
    Names
    Loading...
  • 121
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 90
    Additional
    Loading...
View:
2321 products
Second Mark Shaper Module
Second Mark Shaper Module
Pulse duration: ......10-15 microseconds The duration of the leading edge of the pulse:......no more than 20 ns Pulse amplitude: ...... at least 3V at a load of 50 ohms
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
X-RAY DOSIMETER DKR‑AT1103M
X-RAY DOSIMETER DKR‑AT1103M
A unique highly sensitive device for monitoring dose loads on the lens, mucous membranes and skin Spectrum display mode when connected to a PC It is not intended for measuring the natural radiation background
Produced in: Belarus, Minsk
Universal measuring complex UIM-MD
Universal measuring complex UIM-MD
Stationary complex for monitoring various parameters of the radiation situation, depending on the type of connected detection units: - continuous monitoring of gamma and neutron radiation in rooms and workplaces; - assessment of alpha and beta and gamma contamination of surfaces of objects, personnel clothing and small items. Purpose: measurement: ambient dose equivalent power of photon and neutron radiation; alpha and beta radiation flux densities; surface activity of Pu-239 and Sr-90+Y-90 radionuclides; alarm about exceeding the set thresholds.
Doza
Zelenograd
Produced in: Moscow
Exhaust cabinet for working with acids LAB-PRO SHVK 180.84.230 VI
Exhaust cabinet for working with acids LAB-PRO SHVK 180.84.230 VI
BASIC EQUIPMENT: Working box front guide posts – aluminum profile painted with powder paint (RAL 7035/RAL 5023), in the right rack there are a light switch and 2 splash–proof sockets with a 3.2kW cover (IP54) the front anti-spill side is acid-resistant polished stainless steel. AISI 316 steel rear, upper, side panels – metal painted with powder paint (RAL 7035) with the texture of shagreen leather inner capsule made of polypropylene lined with ceramic plates of the rear and side panels to a height of 380mm 2 dependent lifting screens – tempered glass in aluminum frames, lifting 0-780mm, do not change the dimensions of the cabinet when lifting the upper fixed screen – polypropylene on the upper panel: the LED lamp is dust- and moisture-proof 2x22 W (IP65) is separated from the workspace by tempered glass with a thickness of 4mm flange d=250mm (distance from the back panel to the center of the flange – 170mm) switching box with automatic emergency power off 16A 3 exhaust levels easily removable exhaust visors counterweights are placed in the front pylon racks and are easily serviced Frame base collapsible frame made of rectangular metal profile painted with powder paint (RAL 7035) with the texture of shagreen leather service panel - aluminum profile painted with powder paint (RAL 5023) with the texture of shagreen leather adjustable supports
LOIP
Saint Petersburg
Produced in: Saint Petersburg
2ZVE-100 Electromechanical Vacuum shutter
2ZVE-100 Electromechanical Vacuum shutter
The 2ZVE-100 vacuum shutter with electromechanical drive equipped with conditional passages of 100 mm is designed to overlap vacuum systems in the range of operating pressures from 1x10-6 to 1.07x105 Pa (0.75 x10–8 to 800 mm Hg). Type of shutter 2ZVE-100 pendulum. The 23VE-100 shutter is manufactured in the climatic version of UHL (i.e. for moderate and cold climate) and O (i.e. general) 4 according to GOST 15150-69. The working environment is air and non–aggressive gases and. It is not intended for use in fire and explosive hazardous industries. The 23VE-100 shutter meets the requirements of technical specifications TU 3648-040-00218526-2003. According to the method of protecting a person from electric shock, the gate belongs to Class I electrical equipment according to GOST 12.2.007.0-75.
Produced in: Kazan
HUMAN RADIATION SPECTROMETER SKG‑AT1316
HUMAN RADIATION SPECTROMETER SKG‑AT1316
Calculation of the expected effective dose of internal radiation per year from incorporated 137Cs and 134Cs Flexible software control of the spectrometer functions, the formation of a database and a report on the results of the survey Express control capacity - 15 people per hour The possibility of sharing AT1316(AT1316A) and AT1322(AT1322/1) The possibility of accommodation in a minibus as part of a mobile radiation control laboratory
Produced in: Belarus, Minsk
DOSIMETER‑RADIOMETER MKS‑AT1117M WITH DETECTION UNIT BDKN‑06 AND A SET OF RETARDER SPHERES
DOSIMETER‑RADIOMETER MKS‑AT1117M WITH DETECTION UNIT BDKN‑06 AND A SET OF RETARDER SPHERES
The result of determining the energy distribution of the neutron radiation flux density is used to calculate such quantities as: - integral neutron flux density; - the average energy of neutron radiation in the spectrum; - the average neutron radiation energy by dose; - dose equivalent per unit flow density; - dose equivalent; - effective dose. ▪ Methodological support of measurements ▪ It is possible to supply an expanded set of polyethylene retarder spheres with diameters: 3,5”; 4,5”; 5”; 7”; 9”; 9,5”
Produced in: Belarus, Minsk
Search and diagnostic complex for finding cable damage by acoustic and induction method Athlete KAI-2.1001
Search and diagnostic complex for finding cable damage by acoustic and induction method Athlete KAI-2.1001
Appointment Athlete KAI-2.1001 • Determination of the type of damage and the distance to the place of damage to the cable. • Tracing a cable line up to 10 km. • Determination of cable depth up to 6 m. • Troubleshooting of cable lines by induction method. • Troubleshooting of cable lines by acoustic method. • Cable insulation testing.
Produced in: Kolomna, Moscow region
 Electronic Stopwatch-Meter IVPR-53SCH
Electronic Stopwatch-Meter IVPR-53SCH
from 40 940 ₽
The electronic stopwatch - time parameter meter IVPR-53SCH is a panel device for monitoring and measuring the time parameters of relays, switches and switches of electrical equipment, relay protection, automation and telemechanics.
NPP "ELEKTRONNYE PRIBORY"
Naberezhnye Chelny
Produced in: Tatarstan, Naberezhnye Chelny
MI-10X Magnetic Indicator
MI-10X Magnetic Indicator
from 17 000 ₽
Distinctive features. Compactness Autonomy Maximum ease of handling Energy saving mode Technical specifications Indication of induction levels, MT,: weak magnetization 0...2 average magnetization 2...10 strong magnetization more than 10 Power supply 1 accumulator unit or PP3 battery Current consumption, mA, no more than 8 Operating temperature range, °C -30...+50 Dimensions of the electronic unit, mm 90x50x32 Dimensions of the converter, mm 14x50
Produced in: Moscow
Wireless set for measuring the temperature of ferrous metal melts with logging function
Wireless set for measuring the temperature of ferrous metal melts with logging function
from 86 400 ₽
The kit is designed to measure the temperature of ferrous metal melts. It consists of a digital contact thermometer TK-5.27 complete with a submersible high-temperature probe, designed to measure the temperature of metal melts in the range of +600 ° C ... +1800 ° C. The digital contact thermometer TK-5.27 is equipped with the function of recording measurements in the device's memory, followed by transferring data to a computer and providing reports in the form of tables and graphs. To measure the temperatures of metal melts, disposable thermocouples of the PPR (B) type with a protective tube length of no more than 900 mm are used. The kit is adapted to the replacement blocks of EVRAZTEMP ET-V-09-00. •
Produced in: Moscow