Equipment

2243 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 388
    Names
    Loading...
  • 125
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 98
    Additional
    Loading...
View:
2243 products
General purpose exhaust cabinet LAB-PRO SHV 150.74.230 TR
General purpose exhaust cabinet LAB-PRO SHV 150.74.230 TR
BASIC EQUIPMENT Working box guide racks – aluminum profile painted with powder paint (RAL 7035/RAL 5023)in the right rack there are a light switch and 2 splash–proof sockets with a 3.2kW cover (IP54) the front anti-spill side is acid-resistant polished stainless steel AISI 304 side panels – tempered glass 2 dependent lifting screens – tempered glass in aluminum frames, lifting 0-780mm, do not change the dimensions of the cabinet when lifting the upper fixed screen – metal painted with powder paint (RAL 5023) with the texture of shagreen leather back and top panels – polypropylene LED lamp dust- and moisture-proof (22W IP65) switching box with automatic emergency power off 16A flange d=250mm (the distance from the rear panel to the center of the flange is 170mm) easily removable exhaust visors 3 exhaust levels (lower, side and front) counterweights are placed in the front pylon racks and are easily serviced Frame base collapsible frame made of rectangular metal profile painted with powder paint (RAL 7035) with the texture of shagreen leather service panel – metal box painted with powder paint (RAL 5023) with the texture of shagreen leather: adjustable supports
LOIP
Saint Petersburg
Produced in: Saint Petersburg
ZVPlE-500 Flat Electric Vacuum Shutter
ZVPlE-500 Flat Electric Vacuum Shutter
The ZVPlE-500 shutter consists of a housing with connecting flanges, a shutter mechanism, a lip seal to ensure the tightness of the drive element, cover, and electric drive. The shutter mechanism consists of a carriage, an upper and lower flap, which are pulled together by springs and balls. The carriage moves along the housing guides on bearings. The ZVPlE-500 shutter is opened and closed both by electric drive and manually using a flywheel. To switch to manual control mode, there is a switching device on the electric drive. The manual drive is used to adjust and regulate the shutter. ZVPlE-500 valves are manufactured in climatic versions UHL (i.e. for moderate and cold climate) and O (i.e. general) 4 according to GOST standard 15150-69.
Produced in: Kazan
Digital oscilloscope S8-56
Digital oscilloscope S8-56
The oscilloscope is capable of operating both autonomously and as part of automated measuring systems with interfaces such as USB, RS-232, ETHERNET, IE-488 (CPC). Technical specifications Number of channels 2 The input impedance of the channels is 50 ohms and 1 mOhm Channel bandwidth at an input impedance of 50 ohms from 0 to 350 MHz Channel bandwidth at an input impedance of 1 mOhm from 0 to 200 MHz Sampling rate 1600 MHz The ADC bit rate is 9 BITS Deviation coefficients from 1 mV/div to 50 V/div Scan coefficients from 1 ns/div to 10 s/div Startup modes automatic, standby, single Synchronization internal and external The basic error of measuring the amplitude is ± 3% The basic error of measuring time intervals is ± (0.3 – 20)% Operating temperature range from 5 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 75 VA Overall dimensions, mm 420x213x181 Weight, not more than 7 kg
Produced in: Moscow
Smart submersible reinforced probe L = 300 mm SZPGU.300P with built-in flash memory
Smart submersible reinforced probe L = 300 mm SZPGU.300P with built-in flash memory
from 12 972 ₽
Smart submersible reinforced probe L = 300 mm SZPGU.The 300P with built-in flash memory is designed to measure the temperature of various materials by directly contacting the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor, Android program installed. Operating conditions of the SZPGU.300P smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the SZPGU.300P smart probe Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor, Android program installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect external power. Possibility of calibration.
Produced in: Kolomna, Moscow region
Dosimeter-radiometer ISS-15D "Bullfinch"
Dosimeter-radiometer ISS-15D "Bullfinch"
Dosimeter is a gamma-beta radiation radiometer for working in "dirty" conditions. Allows you to switch modes and take measurements in conditions of radioactive contamination. Measurement of the beta radiation flux density is carried out with automatic subtraction of the gamma radiation background. Purpose: measurement of the ambient dose equivalent of H*(10) gamma radiation; measurement of ambient dose equivalent of H*(10) gamma radiation; measurement of beta particle flux density; estimation of the counting rate with combined measurements of gamma and beta radiation.
Doza
Zelenograd
Produced in: Moscow
Generator of test pulses G9-1A
Generator of test pulses G9-1A
The generator is capable of operating both autonomously and as part of automated measuring systems with interfaces such as RS-232 and ITHERNET. Technical specifications The range of setting the pulse duration at the outputs: - τ1 from 100 ns to 10 s - t2 from 101 ns to 10.1 s - t3 from 10 ns to 3600 s The range of setting the time interval between the pulse fronts at outputs t1 and t2 (∆tx) is from 0 to 3600 s The main error in setting the pulse duration at outputs t1 and t2 ± (δ0 • t1,2 + 1•10-8 c) The basic error of setting the pulse duration at the output is τ3 ± (δ0 •τ3 + 2 •10-9 s) The main error in setting the duration of the time interval (∆tx): ∆tx from 0 to 1000 s ± (δ0 •∆tx + 2•10-10 s) ∆tx from 1000 to 3600 s ± (δ0 •∆tx + 2•10-9 s) Pulse amplitude at outputs τ1 , τ2 and τ3 at a load of 50 ohms, not less than 1.2 V The nominal frequency value of the reference quartz oscillator is 10 MHz Relative error in the frequency of the quartz oscillator (δ0 ), no more than ± 2x10-7 in 24 months The pulse repetition frequency setting range at outputs τ4 and τ5 is from 0.1 Hz to 300 MHz The main error in setting the pulse repetition frequency at outputs τ4 and τ5 ± δ0 •F = τ4.5 Pulse amplitude setting range at outputs τ4 and τ5 from 0.05 to 1 V The main error in setting the pulse amplitude at outputs τ4 and τ5 ± 20% Fixed values of pulse durations at the output of τ6 1 and 5 microseconds The basic error of setting the pulse duration at the output is τ6 ± (0.2•τ6 + 3 •10-7 s) The nominal value of the pulse repetition frequency at the output is τ6 100 kHz The main error in setting the pulse repetition frequency at the output is τ6 ± δ0 •F = τ6 Fixed values of the pulse amplitude at the output of τ6 minus 10 V; minus 2.5 V; 2.5 V; 10 V The main error in setting the pulse amplitude at the output is τ6 ± 20% Operating temperature range from 5°C to 40 °C AC power supply 220 V, 50 Hz Power consumption, not more than 100 VA Overall dimensions, mm 442x160x452 Weight, not more than 10 kg
Produced in: Moscow
Low-frequency signal generator G3-132
Low-frequency signal generator G3-132
Technical specifications: The waveform is sinusoidal, rectangular (TTL) Frequency range from 0.1 Hz to 10 MHz Frequency setting error ±0.02% Frequency instability ±0.01% in 15 min Signal amplitude ± 2.5 V at 50 ohm load ±5 V without load Limits of adjustment of the output signal level from 2 mV to 1.85 V (skz) at a load of 50 ohms from 4 mV to 3.75 V (scz) without load Signal level unevenness ± 5% at frequencies from 0.1 to 10 Hz relative to 1 kHz ± 2% at frequencies from 10 Hz to 1 MHz ±10% at frequencies from 1 to 10 MHz Harmonic coefficient ± 0.2% at frequencies from 10 to 100 Hz ±0.07% at frequencies from 100 Hz to 20 kHz ± 0.2% at frequencies from 20 to 120 kHz ±1% at frequencies from 120 kHz to 1 MHz ±4% at frequencies from 1 to 10 MHz Parameters of the rectangular (TTL) signal form log. "1" 3 2.4 V; log. "0" ≤ 0.4 V In the frequency range from 0.1 Hz to 2 MHz, the duration of the front, the cutoff is not more than 100 ns Operating temperature range from minus 10 °C to + 40 °C Power supply ~230 V, 50 Hz; 10 V×A Dimensions; weight 210×71×255 mm; 2 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Installation of pollution control of personnel RZBA-07D
Installation of pollution control of personnel RZBA-07D
Purpose: measuring the level of contamination of hands, feet (shoes) and clothing of personnel with beta-active substances and signaling when exceeding permissible levels monitoring the level of contamination with alpha-emitting radionuclides monitoring the contamination of personnel at nuclear power plants, nuclear fuel cycle enterprises (NFC), radiological laboratories, other enterprises and institutions using radioactive substances.
Doza
Zelenograd
Produced in: Moscow
Central Heating Unit Medium (CHU-M) Kit
Central Heating Unit Medium (CHU-M) Kit
The kit is designed to control the temperature and pressure at the points of water sampling of hot water and HVAC systems, archiving the measured results for the purpose of their further documentation and analysis. The TSTP-M kit allows you to record changes in temperature and pressure directly at the points of water intake of hot water and HVAC, for a long period. With the subsequent transfer of data recorded in the device's memory to a computer, for printing a report, graph, etc. Features of the CHU-M kit The CHU-M kit allows you to control the pressure and temperature at the hot water and HVAC disassembly points. The kit consists of a four-channel meter recorder, which allows you to store 15,000 values in memory, for each channel with an interval of 5 seconds. up to several hours, which allows you to take measurements and store data for up to 1 year.
Produced in: Kolomna, Moscow region
Digital two-channel contact thermometer TK-5.27 with logging function
Digital two-channel contact thermometer TK-5.27 with logging function
from 28 704 ₽
The digital contact thermometer TK-5.27 is designed to measure the temperature of liquid, bulk, gaseous materials by immersion of measuring probes of thermometers into the medium (immersion measurements), contact measurements of temperatures of surfaces of solids (surface measurements), measurement of relative humidity of gaseous non-aggressive materials, measurement of atmospheric pressure, measurement of air flow velocity, as well as for measuring the luminous flux incident on a small area of the surface to its area. The contact thermometer TK-5.27, depending on the order, is equipped with replaceable probes for various purposes. Two probes of any type can be connected to the TK-5.27 thermometer at the same time. Thermometers TK-5.27 have the function of automatically determining the type of connected probe.
Produced in: Moscow
SPECTROMETERS MKS‑AT6102, MKS‑AT6102A, MKS‑AT6102B
SPECTROMETERS MKS‑AT6102, MKS‑AT6102A, MKS‑AT6102B
Monoblock design Multifunctionality A built-in GPS module Audible, vibration and visual alarms The possibility of connecting external detection units Battery life 25 h (AT6102A,V),18 h (AT6102)
Produced in: Belarus, Minsk
Electronic explosion-proof thermometer ExT-01/3-20
Electronic explosion-proof thermometer ExT-01/3-20
The thermometer sensor ExT-01/3-20 is made in the form of a fully submersible probe with a cable length of 20 meters and has a device for winding it. The thermometer has an explosion protection marking 0Ex ia IIB T4 Ga X and can be used in explosive zones 0, 1 and 2 of any classes of premises and outdoor installations in which the formation of explosive mixtures of categories IIA, IIB is possible. • Measurement range -50...+130 °C Minimum sensor immersion depth full immersion Overall dimensions of the electronic unit 135x65x40 mm Electronic unit weight 0.3 kg
Produced in: Tomsk