2ZVE-630/400R Electromechanical Vacuum shutter with gearbox
2ZVE-630/400R Electromechanical Vacuum shutter with gearbox
The 2ZVE-630/400R vacuum shutter with electromechanical drive equipped with 630 / 400mm conditional passages is designed to overlap vacuum systems in the range of operating pressures from 1x10-6do 1,07x105Pa (0,75x10–8do 800 mm Hg). The 2ZVE-630/400R shutter is pendulum-type. The 23VE-630/400R shutter is manufactured in climatic versions UHL (i.e. for moderate and cold climate) and O (i.e. general) 4 according to GOST standard 15150-69. The working environment is air or non–aggressive gases. It is not intended for use in fire hazardous and explosive industries. The 23VE-630/400R shutter meets the requirements of technical specifications TU 3648-040-00218526-2003. According to the method of protecting a person from electric shock, it belongs to Class I electrical equipment according to GOST 12.2.007.0-75.
Produced in: Kazan
Verification module PM-10
Verification module PM-10
The composition of the PM-10 verification module: Wattmeter of passing power M2-35; Complex transmission and reflection coefficients meter "OBZOR-804/1"; Universal voltmeter V7-81 (2 pcs.); High-frequency signal generator G4-229; High-frequency signal generator G4-230; DC power supply B5-79/1 (2 pcs.); AC power source B2-7 (2 pcs.); The measure of DC electrical resistance is multi-valued MS3070-3, CT 0.005; The measure of DC electrical resistance is multi-valued MS3055, CT 0.02; Single-digit electrical resistance measures MS3080 (0.1; 1 ohm, CT 0.005); Thermoelectric voltage converter 0.5 V; Kit for measuring coaxial connectors KISK-7M; PC, printer; Basic load-bearing structures (BNC). Technical specifications Measuring ranges of electrical and radio engineering quantities: Operating frequency range from 0.03 to 17.85 GHz Passing microwave power from 0.01 to 10 MW VSWR of the microwave tract from 1.05 to 3 Constant electrical voltage from 10 MV to 1000 V Alternating electric voltage from 1 mV to 750 V Thermoelectric voltage comparison from 0.1 to 0.5 V Ranges of reproduction of electrical quantities: Constant electrical voltage from 1 to 120 V Resistance to direct electric current from 0.01 to 122222.21 ohms Measurement errors of electrical and radio engineering quantities: Passing microwave power ± (1.5 - 2.3) % VSWR of the microwave path ± (4,15 – 10) % Constant electrical voltage ± (0.003 – 20) % Alternating electric voltage ± (0.09 - 15) % Thermoelectric voltage comparison ± (0.01 – 0.1) % Errors in the reproduction of electrical quantities: Constant electrical voltage ± (100 – 200) mV Resistance to direct electric current CT 0.005; 0.02 General technical characteristics: The area occupied by the module is 4 – 8 m2 Weight, not more than 340 kg Power supply voltage from 198 to 242 V with a frequency of (50 ± 0.5) Hz Power consumption, not more than 2000 VA
Produced in: Moscow
Laboratory table low Mod. -900 SLL n "Laminate"
Laboratory table low Mod. -900 SLL n "Laminate"
from 17 660.87 ₽
The table is based on a reinforced O-shaped, collapsible metal frame made of shaped tube, rectangular and square cross-sections. The back wall is covered with a metal shield. The table is mounted on adjustable screw bearings, allowing the table to be installed horizontally, regarding the floor unevenness. Frame cover, high-quality powder-polymer paint, perfectly protects the base of the table from the effects of any aggressive liquids. The cover of the frame is easily cleaned with disinfectant solutions. The working surface of the Laminate table is a waterproof chipboard plate covered with chemically resistant and heat-resistant plastic.
Produced in: Saint Petersburg
IPA-01 Wearable Sampler
IPA-01 Wearable Sampler
from 20 000 ₽
Determination of the integral concentration of radioactive aerosols in the personnel breathing area (exposure time 8 hours) by radon (thoron) daughter products and long-lived radionuclides in accordance with the requirements of NRB-99 and OSPORB-99. Automatic stabilization of the air sampling rate. (It is possible to supply additional consumables to IPA - 01)
Produced in: Moscow
IRI-04M Individual Logger-indicator
IRI-04M Individual Logger-indicator
from 87 000 ₽
It is intended for registration and indication of electromagnetic factors and conditions that create a potential spark threat caused by the "human factor", natural phenomena and man-made failures of equipment and power grids, in order to prevent technical operations with gas and oil products.
Produced in: Moscow
Two-channel portable gas chromatograph FGH-1-2
Two-channel portable gas chromatograph FGH-1-2
from 1 030 000 ₽
The FGH-1-2 chromatographs have retained the main advantages of the FGH-1 model – mobility and ease of operation and maintenance. At the same time, FGH-1-2 has all the advantages of a modern multichannel chromatograph – the ability to reliably identify and accurately determine the concentrations of various pollutants of environmental objects. The additional use of automatic identification in the processing of chromatograms simultaneously through both channels makes FGH-1-2, in fact, a universal selective gas analyzer of organic substances using the chromatographic separation method. In FGH-1-2, as well as in FGH-1, all methodological problems have been solved: all measurement methods (MI) used are certified, the devices are equipped with sampling devices prescribed in MI, the devices are graded according to the required substances, independent control of the stability of calibration characteristics and measurement errors is provided.
EKAN
Moscow
Produced in: Moscow
Pulse DC power supply B5-71/5-PRO
Pulse DC power supply B5-71/5-PRO
1 supp.
Regulated switching power supplies with highly stable output characteristics Digital display of set and actual value, voltage and current (4 digits, LED) Electronic load switching on/off Protection against overload, short circuit, overheating and reverse polarity Low ripple output voltage less than 2mV Low ripple output current less than 5mA Minimum discreteness of setting output voltage and current 0.007/0.005 Operating modes: stabilization U and I, dynamic load RS-232 interface
DIPAUL
Saint Petersburg
Produced in: Saint Petersburg
Vibrating liquid density meter VIP-2MR
Vibrating liquid density meter VIP-2MR
The operation of the density meter is based on measuring the oscillation period of a hollow tube of the original configuration filled with the liquid under study, and then calculating the value of its density using the results of preliminary calibration for two substances of known density, for example, air and water. • Maximum viscosity of the measured liquid at ambient temperature 300 mm2/s The nominal volume of the measuring cell is 1.5 ml Measurement time of 2 channels 20 s • Temperature range of the built-in thermostat +15...+60 °C • • Overall dimensions 205x225x80 mm Weight 3 kg Power consumption 15 W
Produced in: Tomsk
Supply and exhaust cabinet with drainage system for working with fuming acids LAB-PRO SHPVK 120.86.230 PP
Supply and exhaust cabinet with drainage system for working with fuming acids LAB-PRO SHPVK 120.86.230 PP
BASIC EQUIPMENT Working box front guide posts – aluminum profile painted with powder paint (RAL 7035/RAL 5023), in the right rack there are a light switch and 2 splash–proof sockets with a 3.2kW cover (IP54) front anti–spill side - polypropylene working surface - polypropylene 15mm thick removable plate 600*600mm with a ceramic granite work surface for placement heating plates (1 pc.) 2 dependent lifting screens filled with transparent PVC, 5mm thick in a polypropylene frame in the lower screen – sliding doors made of transparent PVC with a thickness of 5mm lifting 0-780mm, does not change the dimensions of the cabinet when lifting counterweights are placed in the front pillars-pylons and are easily serviced upper fixed screen – polypropylene inner part the working box is a fully sealed polypropylene capsule with a back wall washing system, a drainage channel and a polypropylene pipe for cold water 3 levels of hoods easily removable polypropylene exhaust canopies polypropylene drain sink on the top panel are placed: LED dust- and moisture-proof lamp (2x10W IP65) separated from the workspace by transparent PVC switching box with automatic emergency power off 16A flange with damper plug for air inflow d=200mm flange with aspiration collector for air outflow d=250mm (distance from the rear panels up to the center of the flange – 155mm) cabinet ventilation system
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Laboratory electronic thermometer LT-300-T
Laboratory electronic thermometer LT-300-T
The measurement range is -50...+300 °C. Up to +200 °C resolution 0.01 °C, error ±0.05 °C (Class C according to ASTM E2877). The minimum immersion depth of the sensor is 75 mm Overall dimensions of the electronic unit 75x80x35 mm Weight 0.2 kg
Produced in: Tomsk
 INDIVIDUAL DOSIMETERS DKG‑AT2503V, DKG‑AT2503V/1, DKG‑AT2503V/2
INDIVIDUAL DOSIMETERS DKG‑AT2503V, DKG‑AT2503V/1, DKG‑AT2503V/2
Control of individual radiation doses from X-ray and gamma radiation. Together with the reader and software, they form an effective system for automated control of dose loads on personnel. ▪ Simultaneous measurement of the power of the individual dose equivalent and the dose of gamma radiation ▪ Automatic compensation of the detector's own background ▪ The mode of signaling the presence of pulsed radiation with a duration of 10 ns (optional)
Produced in: Belarus, Minsk