Portable Electrical Laboratory for testing and searching for cable damage by acoustic and induction method Athlete KAI-2.501
Portable Electrical Laboratory for testing and searching for cable damage by acoustic and induction method Athlete KAI-2.501
• Appointment Athlete KAI-2.501 o Search for a live cable. o Detection of the passage of hidden communications (metal pipelines, cable lines). o Preliminary detection of the distance to the place of damage. o Search for places of cable damage by acoustic method. o Search for places of cable damage by electromagnetic means. o Cable insulation test. o The presence of the "Friend-Foe" mode.
Produced in: Kolomna, Moscow region
"Homeofficer" Optimal kit
"Homeofficer" Optimal kit
from 48 981 ₽
It is designed to measure the temperature and humidity of indoor air, the surface of heating devices, water temperature in heating and hot water supply systems. •
Produced in: Moscow
Picoammeter A2-4
Picoammeter A2-4
System meter of small currents. The device allows to make measurements in almost the entire range of currents. The picoammeter is characterized by high performance, which is important for its use as part of automated measuring systems. Technical specifications: Current measuring range 1x10-14 - 1x10-2 A Error for the range 10-11, 10-10 ±[0.5+0.025(lk/lx-1)]% for the range 10-9, 10-8 ±[0.25+0.01(lk/lx-1)]% for the range 10-7, 10-6,10-5, 10-4,10-3, 10-2 ±[0,1+0,01( lk/lx-1)]% The time of setting the readings is 2x10-2 - 2x10-5 s Supply voltage 230 (±20) V, frequency 50 (± 0.5) Hz Power consumption 10 VA Overall dimensions (HxWxD) 105x284x366 mm Weight 3.5 kg Operating temperature 5 - 40 °C Humidity 80% at 25 °C
MNIPI
Minsk
Produced in: Belarus, Minsk
Immitance Broadband Analyzer E7-28
Immitance Broadband Analyzer E7-28
Technical specifications: Extended frequency range 25 Hz–10 MHz The basic error is ±0.1 % The level of the measuring signal is 5 mV – 1 V S.K.z. Offset voltage (0 – 40) V The discreteness of the operating frequency setting is 1 Hz Graphical analysis of measured values in a given frequency range USB 2.0 interface
MNIPI
Minsk
Produced in: Belarus, Minsk
Measuring antenna P6-62
Measuring antenna P6-62
1 supp.
Technical specifications: Frequency range (300-1000) MHz SWR < 2 The limit of permissible error of the antenna coefficient, not more than ± 2.0 dB Orthogonal polarization signal level -20 dB Ambient air temperature from - 50 to + 60 Relative humidity of 95 % at + 35 ° C Overall dimensions (HxWxD) 400x145x150 mm Weight 1 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
X‑RAY AND GAMMA RADIATION DOSIMETERS DKS‑AT1121, DKS‑AT1123
X‑RAY AND GAMMA RADIATION DOSIMETERS DKS‑AT1121, DKS‑AT1123
Measurements in wide ranges of capacities doses and energies Measurement of dose rate and duration of exposure during short-term radiation from 0.03 s Measurement of the average dose rate of pulsed radiation with a pulse duration of 10 ns (AT1123) The possibility of remote measurements using a remote control The possibility of stationary location with external audible and visual alarms with "dry" contacts for controlling actuators The possibility to connect to a PC for organizing a continuous monitoring system with a documentation function
Produced in: Belarus, Minsk
High-frequency signal generator G4-229
High-frequency signal generator G4-229
The generator is capable of operating both independently and as part of automated measuring systems with USB and IEEE-488 (CPC) interfaces. Technical specifications Frequency range (RF output) from 9 kHz to 6 GHz Frequency range (LF outputs) from 0.001 Hz to 30 MHz Frequency tuning discreteness (RF output) 1 Hz Frequency tuning discreteness (LF outputs) 0.001 Hz The main error of the frequency setting is ± 3x10-7 Hz The range of setting the output signal power level at the main RF output is from minus 120 to 13 dBm The range of setting the signal amplitude at a load of 50 ohms (LF outputs) from 0.01 to 5 V The basic error of setting the reference power level (RF output) ± (0.5 – 1.0) dB The basic error of setting the amplitude of sinusoidal signals (LF outputs) ± (3 – 15)% Instability of the signal power level for any 15-minute time interval (RF output) no more than 0.1 dB Metrological characteristics of the generator in the FM operation mode: - frequency range of the modulating signal from 1 to 100 kHz - frequency deviation setting range (taking into account the carrier frequency value) from 12.5 to 4000 kHz - the basic error of setting the frequency deviation ± (10 – 20)% Metrological characteristics of the generator in AM operation mode: - frequency range of the modulating signal from 0.05 to 5.0 kHz - the range of setting the amplitude modulation coefficient from 1 to 100 % - the basic error of setting the amplitude modulation coefficient (when operating from an internal signal source) ± (0.15 M + 0.2)% Metrological characteristics of the generator in the IM operation mode: - the duration range of modulating pulses from 100 ns to 20 s - the range of the modulating pulse repetition period from 140 ns to 30 s - the difference in the duration of the output RF pulses from the duration of the modulating pulses ± 100 ns Operating temperature range from minus 10 to 40 °C AC power supply 220 V, 50 Hz Power consumption, not more than 100 VA Overall dimensions, mm 498x136x487 Weight, not more than 15 kg
Produced in: Moscow
 VD-41P Eddy Current Flaw Detector
VD-41P Eddy Current Flaw Detector
Scope of application The VD-41P eddy current flaw detector is designed to work as part of automated quality control lines at pipe-rolling and metal-rolling enterprises with continuous output control of products together with other auxiliary devices: a paint meter, a path sensor, an object presence sensor, an automatic sorter, a demagnetizer. The device can also be used for input control at machine-building enterprises of the automotive, aviation, oil and gas, and agricultural industries. Technical specifications: Control frequencies: 1.0 – 100 kHz. Control speed (line speed): 0.5 - 5 m/s. The high-frequency filter is automatically adjustable depending on the speed. Signal phase adjustment: 0 - 359° . Converter current adjustment: 50 – 500mA. Automatic monitoring of the operability of the measuring converter. Data processing: - Software adjustable filter. - Signal evaluation using signal masks: - circular mask, - sector masks. - Sorting by control results. Display: 10.2” (26 cm) touch LCD (800x600). Operating system used: WINDOWS® 7. Dialog language: Russian, other languages (optional). Applicable eddy current converters: overhead type, through type, sector type. Interfaces: - Connector for the converter unit. - External automation control connector. - 4 outputs with delay adjustment - "dry contact". - 2 external information inputs. - VGA interface for connecting an external monitor. - USB 2.0. - Network: Ethernet (TCP/IP). - Other interfaces on special order. Power supply: 220 V, 50 Hz. Operating temperature range: 0 to +40°C. Type of climatic performance - UHL 4 (i.e. for moderate and cold climate). Enclosure protection degree: IP 53. Dimensions, w/h/d: 471 x 285 x 460 mm / can be built in a 19” rack/cabinet. Weight: approx. 20 kg.
Produced in: Moscow
X-ray Radiation Dosimeters Clinical DRC
X-ray Radiation Dosimeters Clinical DRC
X–ray radiation dosimeters clinical DRC, depending on the modification, are designed for: measuring the product of the kerma (absorbed dose) in the air by the cross-sectional area of the X-ray beam (hereinafter referred to as the product of the kerma in the air by the area) when using the DRC-1, DRC-1E, DRC-1M Outline, DRC-1M dosimeters with the DRC measuring console-1M-E03, DRC-1M-E04, DRC-1M-E05, DRC-1M-E06; measurements of the product of the kerma power (absorbed dose) in the air per area (hereinafter referred to as the product of the kerma power in the air per area) using the DRK–1E and DRK-1M dosimeters equipped with the DRK-1M-E06 measuring console; measurements of the product of the kerma (absorbed dose) in the air along the length (hereinafter referred to as the product of the kerma in the air along the length) using DRK-1M-CT dosimeters; measurements of kerma (absorbed dose) in the air; measurements of the kerma power (absorbed dose) in the air when using DRK-1M dosimeters.
Doza
Zelenograd
Produced in: Moscow
Supply and exhaust cabinet with drainage system for working with fuming acids LAB-PRO SHPVK 180.86.230 PP
Supply and exhaust cabinet with drainage system for working with fuming acids LAB-PRO SHPVK 180.86.230 PP
BASIC EQUIPMENT Working box front guide posts – aluminum profile painted with powder paint (RAL 7035/RAL 5023), in the right rack there are a light switch and 2 splash–proof sockets with a 3.2kW cover (IP54) front anti–spill side - polypropylene working surface - polypropylene 15mm thick removable plate 600*600mm with a ceramic granite work surface for placement heating plates (2 pcs.) 2 dependent lifting screens filled with transparent PVC, 5mm thick in a polypropylene frame in the lower screen – sliding doors made of transparent PVC with a thickness of 5mm lifting 0-780mm, does not change the dimensions of the cabinet when lifting the counterweights are placed in the front pillars-pylons and are easily serviced upper fixed screen – polypropylene inner part the working box is a fully sealed polypropylene capsule with a back wall washing system, a drainage channel and a polypropylene pipe for cold water 3 levels of hoods easily removable polypropylene exhaust canopies polypropylene drain sink on the top panel are placed: LED dust- and moisture-proof lamp (2X22W IP65) separated from the workspace by transparent PVC switching box with automatic emergency power off 16A flange with damper plug for air inflow d=200mm flange with aspiration collector for air outflow d=250mm (distance from the rear panels up to the center of the flange – 155mm) cabinet ventilation system
LOIP
Saint Petersburg
Produced in: Saint Petersburg