Equipment

2246 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 388
    Names
    Loading...
  • 125
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 98
    Additional
    Loading...
View:
2246 products
Electronic milk viscometer "Expert Somatos - 01"
Electronic milk viscometer "Expert Somatos - 01"
from 69 000 ₽
1 supp.
Electronic milk viscometer (analyzer of the number of somatic cells in milk) Expert Somatos is a novelty of 2020! Modern, designed taking into account all the wishes of our customers over the past 12 years! The most accurate and most reliable! It fully complies with GOST 23453-2014 (Raw milk. Methods for the determination of somatic cells. Section 6: Method for determining the number of somatic cells using a viscometer) as amended on 01.01.2016, including the length and diameter of the capillary! The analyzer is included in the state register of the Russian Federation as a measuring instrument! Exclusive benefits: • version with one or two flasks, which allows up to 60 measurements per hour • optionally equipped with an integrated or external printer • thanks to the new verification method developed from scratch, it can be trusted in any standardization and metrology center As a rule, it is used: • Dairy farms — for the timely prevention and treatment of mastitis in cows, which ensures stable supplies of high-grade milk (accordingly increases the cost of products). • Veterinary laboratories, SBBS, points for receiving farm milk from the population to determine the grade and calculate the cost of raw milk. • In the laboratories of milk processing enterprises to control incoming raw milk.
LABORATORIKA
Krasnoobsk
Produced in: Novosibirsk region
Smart submersible probe  L=300 mm SZPG.300
Smart submersible probe L=300 mm SZPG.300
from 11 454 ₽
The smart submersible probe L=300 mm SZPG.300 is designed to measure the temperature of various materials by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor, Android program installed. Operating conditions of the SZPG.300 smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the SZPG.300 smart probe Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor, Android program installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
"Home officer" Plus Kit
"Home officer" Plus Kit
from 61 620 ₽
Designed for: – measurement and registration of air temperature, temperature of hot water supply, surface of heating devices; – measurement and registration of relative humidity; – saving data to a memory card with subsequent transfer to a PC for generating reports; – measurement accuracy from ± 0.2 ° C.
Produced in: Moscow
High-frequency signal generator G4-230
High-frequency signal generator G4-230
The generator is capable of operating both autonomously and as part of automated measuring systems with USB and IEEE-488 (CPC) interfaces. Technical specifications Frequency range from 5 to 17.85 GHz Frequency tuning discreteness 0.001 Hz The main error of the frequency setting is ± 3x10-7 Hz The range of setting the output signal power level at the main output is from minus 110 to 13 dBm The basic error of setting the reference power level is ± 1.0 dB Instability of the output signal power level for any 15-minute time interval of no more than 0.1 dB Metrological characteristics of the generator in the FM operation mode: - frequency range of the modulating signal: low frequency from 1 Hz to 20 kHz RFM from 10 to 100 kHz - frequency deviation setting range (taking into account the carrier frequency value): low frequency from 1 Hz to 100 kHz RFM from 50 to 10000 kHz - the main error of the frequency deviation setting is ± (3 – 18)% Metrological characteristics of the generator in AM operation mode: - frequency range of the modulating signal from 0.05 to 5.0 kHz - the range of setting the amplitude modulation coefficient from 1 to 50 % - the main error in setting the amplitude modulation coefficient: Internal ± (0.15M + 0.2)% External ± (0.20M + 0.5)% Metrological characteristics of the generator in the IM operation mode: - the duration range of modulating pulses from 100 ns to 20 s - the range of the modulating pulse repetition period from 140 ns to 30 s - the difference in the duration of the output RF pulses from the duration of the modulating pulses ± 100 ns Operating temperature range from minus 10 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 150 VA Overall dimensions, mm 498x136x487 Weight, not more than 15 kg
Produced in: Moscow
Smart submersible probe L=150 mm SZPG.150P with built-in flash memory
Smart submersible probe L=150 mm SZPG.150P with built-in flash memory
from 9 960 ₽
The smart submersible probe L=150 mm SZPG.150P with built-in flash memory is designed to measure the temperature of various materials by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor, Android program installed. Operating conditions of the SZPG.150P smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the SZPG.150P smart probe Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmission of data about measured physical quantities via Bluetooth to a device with the ThermoMonitor, Android program installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect external power. Possibility of calibration.
Produced in: Kolomna, Moscow region
Exhaust cabinet with integrated glass-ceramic hob LAB-PRO SHVVP 150.84.230 VI
Exhaust cabinet with integrated glass-ceramic hob LAB-PRO SHVVP 150.84.230 VI
BASIC EQUIPMENT Working box front guide posts – aluminum profile painted with powder paint (RAL 7035/RAL 5023), in the right rack there are a light switch and 2 splash–proof sockets with a 3.2kW cover (IP54) the front anti-spill side is acid-resistant polished stainless steel. steel (AISI 316) rear, upper, side panels – metal painted with powder paint (RAL 7035) with the texture of shagreen leather inner capsule made of polypropylene lined with ceramic plates of the rear and side panels to a height of 380mm 2 dependent lifting screens – tempered glass in aluminum frames, lifting 0-780mm, do not change the dimensions of the cabinet when lifting the upper fixed screen – polypropylene on the upper panel: LED dust– and moisture-proof lamp 2x22 W (IP65) is separated from the working space by tempered glass with a thickness of 4mm flange d=250mm (distance from the back panel to the center of the flange - 170mm) switching box with automatic emergency power off 16A 3 extraction levels easily removable exhaust canopies the glass ceramic heating platform is located on the left side of the countertop size 640*500mm (working area 580*430mm, 2 independent heating zones) power up to 5.7kW heating up to 400 ° C counterweights are placed in the front pylon racks and are easily serviced The frame base is a collapsible frame made of a rectangular metal profile painted with powder paint (RAL 7035) with the texture of shagreen leather the service panel is an aluminum profile painted with powder paint (RAL 5023) with the texture of shagreen leather adjustable supports.
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Dosimeter SUR-1TS
Dosimeter SUR-1TS
The possibility of a qualitative assessment of the current radiation situation - continuously and under any conditions. You can put the device in your pocket, purse, etc. and forget about it. If you get into the zone of radioactive exposure, the alarm will immediately remind you of yourself and let you know about the danger with light and sound signals; The presence of light and sound alarms about the emergency level of radiation hazard; Durable body is made of cast duralumin; Protected by the copyright certificate, the original power supply circuit, which provides low current consumption, allows you to keep the device constantly on and instantly determine whether it enters the zone of radioactive danger; The possibility to operate the device without replacing the battery for a year or more.
NPP "ELEKTRONNYE PRIBORY"
Naberezhnye Chelny
Produced in: Tatarstan, Naberezhnye Chelny
Verification module PM-9
Verification module PM-9
The composition of the PM-9 calibration module: Universal voltmeter calibrator H4-12 (2 pcs.); Variable voltage calibrator H5-5A; A measure of the stress ratio H4-8; AC voltage voltmeter VK3-78A; Generator-calibrator of harmonic signals SK6-122; The meter-calibrator of the harmonic coefficient SK6-20A; AC power source B2-7 (2 pcs.); The measure of DC electrical resistance is multi-valued MS3070-2; The measure of DC electrical resistance is multi-valued MS3055; Decadal high-resistance resistance magazine M-109R; Single-digit electrical resistance measures MS3080 (0.001; 0.01; 0.1 ohms); Electrical resistance measures unambiguous MS3050M (1, 10, 100, 1000, 10000, 100000 Om); The measure of electrical resistance is unambiguous P4013; The measure of electrical resistance is unambiguous P4023; The measure of electrical resistance is unambiguous P4033; PC, printer; Basic load-bearing structures (BNC). Technical specifications Measuring ranges of electrical quantities: Constant electrical voltage DC from 1 MV to 1000 V AC alternating electric voltage in the frequency range of 10 Hz ... 1 MHz from 10 mV to 1000 V Alternating electric voltage high-frequency VRF in the frequency range of 10 Hz ... 2000 MHz from 10 mV to 100 V Harmonic coefficient in the frequency range of 10 Hz ... 200 kHz from 0.001 to 100 % Ranges of reproduction of electrical quantities: Constant electrical voltage DC from 1 nV to 1000 V AC alternating electric voltage in the frequency range of 10 Hz ... 1 MHz from 3 MV to 1000 V Alternating electric voltage high-frequency VRF in the frequency range of 1 MHz ... 2000 MHz from 3 MV to 3 V DC electric current from 1 µA to 20 A The power of alternating electric current in the frequency range from 0.1 Hz to 10 kHz from 1 µA to 20 A Electrical resistance from 0.001 ohms to 11 ohms Harmonic coefficient in the frequency range from 10 Hz to 200 kHz from 0.001 to 100 % Measurement errors of electrical quantities: Constant electrical voltage DC ± (0.0011 ... 4.0) % AC alternating electric voltage, in the frequency range 10 Hz ... 1 MHz ± (0.0055 ... 1.2) % Alternating electric voltage high-frequency VRF in the frequency range 1 MHz ... 2000 MHz ± (0.2 ... 6.0) % Harmonic coefficient in the frequency range from 10 Hz to 200 kHz ± (0.0008 ... 2.0) % Errors in the reproduction of electrical quantities: Constant electrical voltage DC ± (0.0011 ... 4.0) % AC alternating electric voltage in the frequency range 10 Hz ... 1 MHz ± (0.0055 ... 4.0) % Alternating electric voltage high-frequency VRF in the frequency range 1 MHz ... 2000 MHz ± (0.6 ... 10.0) % DC power ± (0.0033 ... 0.5) % The power of alternating electric current in the frequency range from 10 Hz to 10 kHz ± (0.055 ... 1.0) % Electrical resistance ± (0.001 ... 1.0) % Harmonic coefficient in the frequency range from 10 Hz to 200 kHz ± (0.006 ... 2.0) % General technical characteristics: The area occupied by the module is 6-12 m2 Weight, not more than 430 kg Power supply voltage from 198 to 242 V with a frequency of (50 ± 0.5) Hz Power consumption, no more than 2000 VA
Produced in: Moscow
EVRAZOXY For high oxidation
EVRAZOXY For high oxidation
Purpose: Measurement of oxygen activity in molten steel Scope of application: Oxygen converters, electric arc furnaces, induction furnaces, blast furnaces, casting buckets Measurement range: from 50 to 2000 ppm O2 - metal oxidation from 1000 to 1800 °C - metal temperature from 0.010 to 0.200% - carbon content Accuracy: 0 + 3°C at 1554°C; (from 5 to 10) mV (depending on the level of oxygen activity) Measurement time: 8 sec Tube Length: from 100 to 1500 mm (other lengths are available on request) Slag Cap: Steel, cardboard Type of NSH: B, S, R
Produced in: Lipetsk
MKS‑AT6101DR SPECTROMETER (STATIONARY VERSION)
MKS‑AT6101DR SPECTROMETER (STATIONARY VERSION)
▪ Measurements without sampling in geometry 4π ▪ Intelligent detection unit in an airtight container ▪ The possibility of further detailed processing of the measured data using specialized software
Produced in: Belarus, Minsk
MF-23IM Flaw detection magnetometer
MF-23IM Flaw detection magnetometer
from 193 200 ₽
The MF-23IM flaw detection magnetometer allows you to determine the compliance of the ratio of the tangential and normal components of the magnetic field strength during magnetic particle testing using both the applied field method (AFM) and the remanent magnetization method (RMM) in accordance with the requirements of current regulatory documentation. The MF-23IM flaw detection magnetometer meets the requirements in the field of non-destructive testing for the main industries: nuclear, energy, oil and gas complex, general and special engineering, railway transport, aerospace industry, elevator and crane facilities.

The flaw detection magnetometer is included in the State Register of Measuring Instruments (GRSI) under No. 20106-00. The magnetometer (milliteslameter) is also included in the register of measuring instruments, testing equipment and measurement methods used at JSC Russian Railways. The flaw detection magnetometer MF-23IM from the manufacturer is used to measure the parameters of constant, variable (industrial frequency) and pulsed magnetic fields when testing ferromagnetic products using the magnetic particle method, as well as to control the level of industrial interference. Specifications.
Magnetic field induction (strength) measurement range: - constant and variable (amplitude and average values) 0.5…1000 mT (4…8000 A/cm) - pulsed (amplitude value) 2…1000 mT (18…8000 A/cm) Indication of measurement results digital or digital + graphic Indicator liquid crystal display Power supply from 1 PP3 battery Current consumption, mA, no more than 15 Memory capacity for storing results 4080 Communication with a computer via infrared channel Dimensions of the electronic unit, mm, no more than 120x60x25 Weight of the electronic unit with battery, g 150

The minimum dimensions of the Hall transducer for the MF-23IM magnetometer make it possible to measure the induction and magnetic field strength in grooves, grooves, corner transitions, i.e. in those areas of the controlled product that are stress concentrators and the most dangerous from the point of view of crack formation; · Measurement of pulsed magnetizing field with pulse duration from 0.5 ms; · Small measurement error (see technical specifications table) · Compact size and low power consumption;

· The magnetometer has 2 modes for displaying measurement results – digital and graphic). The MF-23IM magnetometer in graphical display mode allows you to detect a demagnetizing pulse by displaying its shape and amplitude on a graphic display, as a result of which changes can be made to the magnetization circuit in a timely manner. · The software of the MF-23IM magnetometer allows you to flexibly configure not only the response thresholds, but also the time base, which allows you to tune out false indications caused by reverse emissions of the magnetic field or electromagnetic interference from operating power equipment (magnetizing devices or magnetic particle flaw detectors).

· Determination of the effective magnetization region, within which the tangential component of the magnetic field strength is sufficient for magnetic particle testing, and the ratio of the normal and tangential components of the magnetic field strength is less than or equal to 3. · Checking the mode of magnetization/demagnetization of test objects for compliance with the methodology/technological instructions for magnetic particle testing for a given object.

BASIC SET: Electronic unit Converter 1 Converter 2 Caliber PP3 battery CD with program Case Flaw detection magnetometer MF-23IM. Passport
Produced in: Moscow
Metolab 502 Vickers Hardness Tester
Metolab 502 Vickers Hardness Tester
The stationary METOLAB 502 hardness tester is a modification of the METOLAB 501 series device, equipped with a display and a digital micrometer that allows you to automatically read values without the need for conversion tables. The device also automatically calculates the hardness of the samples. The METOLAB 502 microhardometer is designed to measure the hardness of various samples and products (steels, cast iron, non-ferrous metals and soft alloys) according to the Vickers (HV) and Knup (HK) scales in full compliance with GOST R ISO 6507-1-2007. The device has high accuracy, performs measurements in a wide range and with high repeatability. The stationary automatic METOLAB 502 hardness tester is included in the State Register of Measuring Instruments of the Russian Federation (GRSI) under the number 66668-17 and comes with a certificate of primary verification (on request). Distinctive features of the stationary METOLAB 502 Micro-Vickers hardness tester: Built-in digital micrometer that allows you to automatically read readings without the need for translation tables; Automatic hardness calculation; Simple and intuitive control of the device, fully Russified menu; Wide range of measured values – from 5 to 2500 HV; A wide range of applied test loads - 0.09807 N (10 g), 0.2452 N (25 g), 0.4903 N (50 g), 0.9807 N (100 g), 1.961 N (200 g), 2.942 N (300 g), 4.904 N (500 g), 9.80 N (1 kg); Large and bright LCD display. Basic delivery package: Stationary METOLAB 502 Micro-Vickers Hardness Tester; Standard hardness sample – 2 pcs.; Flat desktop; Large flat desktop; V-shaped desktop; Micrometer; Diamond indenter with an angle of 136°; User Manual.
Metolab
Moscow
Produced in: Moscow