Device for automatic isolation of nucleic acids COLIBRI
Device for automatic isolation of nucleic acids COLIBRI
from 2 840 000 ₽
1 supp.
The open system allows you to work with reagents and laboratory plastics from various manufacturers Russian-language software Modifications: - COLIBRI 24 - the ability to select from 1 to 24 samples - COLIBRI 48 - the ability to select from 1 to 48 samples - COLIBRI 96 - the ability to select from 1 to 96 samples Range of working volumes: - COLIBRI 24 - 200 – 5000 mkl - COLIBRI 48 - 30 – 1000 mkl - COLIBRI 96 - 20 – 1000 mkl A unique format of consumable plastic - 8-hole strips and combs Two built-in thermostats The accuracy of temperature maintenance is ± 1 °C Heating/cooling - up to 100 °C / up to 35 °C Universal Thermostat Tube Unit Built-in computer Ready-made allocation protocols The time of one extraction cycle is from 11 minutes Built-in bactericidal UV lamp for interior treatment
SYNTOL
Москва
Produced in: Moscow
Exhaust cabinet for working with LVZH LAB-PRO SHVLVZH-D 120.84.230 KG
Exhaust cabinet for working with LVZH LAB-PRO SHVLVZH-D 120.84.230 KG
BASIC EQUIPMENT Working box front guide posts – aluminum profile painted with powder paint (RAL 7035/RAL 5023), in the right rack there are a light switch and 2 splash–proof sockets with a 3.2kW cover (IP54) the front anti-spill side is acid-resistant polished stainless steel. AISI 304 steel back, top, side panels – metal painted with powder paint (RAL 7035) with the texture of shagreen leather 2 dependent lifting screens – tempered glass in aluminum frames, lifting 0-780mm, do not change the dimensions of the cabinet when lifting the upper fixed screen – tempered glass in an aluminum frame on the upper panel: 4 anti-explosion valves LED lamp dust- and moisture-proof 2x10 W (IP65) is separated from the workspace by tempered glass thickness of 4mm flange d=250mm (distance from the back panel to the center of the flange – 170mm) 3 exhaust levels on the rear panel: 4 holes d =22mm with plugs made of stainless steel for the installation of additional pipes or taps technological hole d=50mm with a plastic plug counterweights are placed in the front pillars-pylons and are easily serviced Frame base collapsible frame made of rectangular metal profile painted with powder paint (RAL 7035) with the texture of shagreen leather service panel - aluminum profile painted with powder paint (RAL 5023) with the texture of shagreen leather module with two drawers
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Laboratory electronic thermometer LT-300-N
Laboratory electronic thermometer LT-300-N
The measurement range is -50...+300 °C. Up to +200 °C resolution 0.01 °C, error ±0.05 °C (Class C according to ASTM E2877). The minimum immersion depth of the sensor is 75 mm Overall dimensions of the electronic unit 75x80x35 mm Weight 0.2 kg
Produced in: Tomsk
Generator G6-46
Generator G6-46
Technical specifications: Frequency range, from 0.1 Hz to 1 Frequency range, from 0.1 Hz to 1 MHz Frequency setting error, ± 1 % Signal amplitude: - at a load of 600 ohms - without load, not less than 5 V (10 V span) not less than 10 V (20 V span)Smooth signal attenuation, at least 20 dB Frequency stability in 15 minutes, no more than 0.5% Hz Frequency setting error, ± 1 % Signal amplitude: - at a load of 600 ohms - without load, not less than 5 V (10 V span) not less than 10 V (20 V span) Smooth signal attenuation, at least 20 dB Frequency instability in 15 minutes, no more than 0.5 %
MNIPI
Minsk
Produced in: Belarus, Minsk