Allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 9 to 16 mm.
The design of the holder eliminates damage to glass thermometers.
It is designed for calibration thermostats THERMOTEST-100 and THERMOTEST-300.
It is intended for placing vessels with samples in the working baths of the BNTI 05 04 bath when determining the low-temperature properties of petroleum products, if appropriate test vessels are available.
Suitable for placing vessels with samples for the State Standard 20287 (Method A), EN 23015 or ASTM D97.
It is intended for placement in the BF bath and is used in determining the mass fraction of paraffins in oil in accordance with the method A of the State Standard 11851.
A set of devices is used to determine the oil content in oil paraffins in accordance with the State Standard 9090 and is intended for placement in a liquid bath BNTI 05 04.
If you are going to use an electronic thermometer LT 300, LT or LTA not in the laboratory, but in the non-laboratory condiditions, this durable case with a lid will protect the sensor from damage.
The size of the case is determined by the length of of your thermometer.
It is designed for simultaneous polishing of four copper plates measuring 75×12.5×2 mm used in determining the corrosive effect of fuels in accordance with GOST ISO 2160, GOST 32329, GOST 6321, GOST 2917 and ASTM D130.
The spring holder for LT 300 or LT electronic thermometers allows you to simply and securely mount the temperature sensor on the walls of laboratory utensils so that it does not touch either its bottom or the wall.
This allows temperature measurements to be carried out not only conveniently, but also correctly.
The holder with flat steel springs allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 9 to 16 mm.
It is designed for THERMOTEST 05 and THERMOTEST-05-1 thermostats.
It is used for determining the low-temperature characteristics of petroleum products in accordance with the State Standard 20287 (Method A), EN 23015 and ASTM D97
It is used in determining the density of petroleum products, resins, plasticizers and other chemical products by hydrometers in stainless steel cylinders with a height of 300 mm and internal diameters of 60.5 and 73 mm.
The holder with flat steel springs allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 16 to 20 mm.
It is designed for calibration thermostats THERMOTEST-100 and THERMOTEST-300.
It is used in determining the flow temperature of petroleum products in accordance with GOST 20287 (method A).
For testing, additional sets of devices BNTI 05 04 K and BNTI 05 04 3K are required
It is used in determining the low-temperature characteristics of petroleum products and organic chemical products in accordance with the State Standard 5066 (Method B) and GOST 18995.5.
Allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 9 to 16 mm.
The design of the holder eliminates damage to glass thermometers.
It is designed for calibration thermostats THERMOTEST-100 and THERMOTEST-300.
It provides convenience in measurements, allowing you to install viscometers at eye level.
The wheels make it easy to move heavy thermostats when needed.
Overall dimensions 650x450x550 mm
It is intended for placing vessels with samples in the working baths of the BNTI 05 04 bath when determining the low-temperature properties of petroleum products, if appropriate test vessels are available.
Suitable for placing vessels with samples for the State Standard 20287 (Method A), EN 23015 or ASTM D97.
ConFlat (CF) standard connections are used еo ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
It is designed to accommodate thermostatically controlled objects in the inner bath of the T40 liquid thermostat.
A basket with a height-adjustable bottom allows objects to be immersed in the coolant to the required depth.
Overall dimensions 305x305x390 mm
Internal dimensions 260x250mm
Weight 2.8 kg
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
It is intended for placement in the BF bath and is used in determining the mass fraction of paraffins in oil in accordance with the method A of the State Standard 11851.
It is intended for placement in the inner bath of the liquid thermostat VT25 or VT25-2 forms with samples when testing grouting cements in accordance with the State Standard 26798.2.
Ventilation openings are nedeed for better convection of the coolant.
Internal dimensions 290x250x140 mm
Weight 2.5 kg
It is designed to improve short-term temperature stability during verification and calibration of electronic thermometers LT 300 (except LT-300-F), LT and ExT-01/1 in calibration thermostats TERMOTEST 100, TERMOTEST-100-40, TERMOTEST 05 and TERMOTEST-05-1.
The stainless steel stand is designed for installation and storage of pressure gauges MTIf 100, MTIf 160 and MTIf 400 in the process of determining the absolute vapor pressure of volatile crude oil and volatile non-viscous petroleum products.
Overall dimensions 170x95x105 mm
Weight 0.5 kg
Gas-tight containers "GPK-10.0,9/9" are intended for use as part of the shaft furnaces "SSHO-10.5.22/10" for heat treatment in an oxidizing environment.
Optionally, the gas supply and mixing system "SPSG" is supplied.