Metrology

527 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 23
    Applying
    Loading...
  • 196
    Names
    Loading...
  • 54
    Manufacturer
    Loading...
  • 33
    Made in
    Loading...
  • 50
    Additional
    Loading...
View:
527 products
Smart submersible probe  L=300 mm SZPG.300
Smart submersible probe L=300 mm SZPG.300
from 11 454 ₽
The smart submersible probe L=300 mm SZPG.300 is designed to measure the temperature of various materials by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor, Android program installed. Operating conditions of the SZPG.300 smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the SZPG.300 smart probe Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor, Android program installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
Electronic milk viscometer "Expert Somatos - 01"
Electronic milk viscometer "Expert Somatos - 01"
from 69 000 ₽
1 supp.
Electronic milk viscometer (analyzer of the number of somatic cells in milk) Expert Somatos is a novelty of 2020! Modern, designed taking into account all the wishes of our customers over the past 12 years! The most accurate and most reliable! It fully complies with GOST 23453-2014 (Raw milk. Methods for the determination of somatic cells. Section 6: Method for determining the number of somatic cells using a viscometer) as amended on 01.01.2016, including the length and diameter of the capillary! The analyzer is included in the state register of the Russian Federation as a measuring instrument! Exclusive benefits: • version with one or two flasks, which allows up to 60 measurements per hour • optionally equipped with an integrated or external printer • thanks to the new verification method developed from scratch, it can be trusted in any standardization and metrology center As a rule, it is used: • Dairy farms — for the timely prevention and treatment of mastitis in cows, which ensures stable supplies of high-grade milk (accordingly increases the cost of products). • Veterinary laboratories, SBBS, points for receiving farm milk from the population to determine the grade and calculate the cost of raw milk. • In the laboratories of milk processing enterprises to control incoming raw milk.
LABORATORIKA
Krasnoobsk
Produced in: Novosibirsk region
AD-42IP Acoustic Flaw Detector
AD-42IP Acoustic Flaw Detector
from 383 500 ₽
It is especially effective for use in products made of composite materials (including with honeycomb filler). Distinctive features: The AD-42 IP is a compact acoustic system sensitive to changes in mechanical impedance caused by product defects. The indication of the device indicates that there are voids, non-adhesives, delaminations or changes in the structure of composite materials (including with honeycomb filler and laminated plastics) under the sensor. The device is used to monitor various materials and their combinations. The energy consumption of the unit is low because the converter is switched on when the sensor is placed on the monitored product. Being light enough, the device allows you to perform monitoring in hard-to-reach places or in confined spaces. The results of the control can be stored in the built-in non-volatile memory and transferred to a PC. Converters Options: - 3 types of converters for various tasks Emitters: - 1 or 2 on each converter Switching-on: - The converters are switched on when they are placed on a controlled object. Technical characteristics: Weight, kg: 0.73 Dimensions, mm: 210x150x70 Power supply: 4 AA batteries Work without recharging the battery, h: 8 Battery discharge visual indication The defect alarm is visual on the converter and audible on the instrument panel (or) in headphones.
Produced in: Moscow
Smart microclimate wall-mounted probe (measurements of atmospheric pressure, temperature and humidity) SPM
Smart microclimate wall-mounted probe (measurements of atmospheric pressure, temperature and humidity) SPM
from 16 698 ₽
Wall-mounted microclimate smart probe (measurement of atmospheric pressure, temperature and humidity) The SPM is designed to measure the temperature of gaseous materials without mechanical impurities and aggressive vapors, relative humidity, atmospheric pressure by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the installed ThermoMonitor based on the Android program. Operating conditions of the SPM smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the SPM smart probe Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor. The Android program is installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
eLajt03 Luxmeter
eLajt03 Luxmeter
from 26 900 ₽
Certified luxmeter sensor with pulse meter and brightness meter functions for connection to a PC (via USB), BOI-01, BOI-02 and Ecofizika units.
Eco-E
Москва
Produced in: Moscow
Portable Electrical Laboratory for testing and searching for cable damage by acoustic and induction method Athlete KAI-2.501
Portable Electrical Laboratory for testing and searching for cable damage by acoustic and induction method Athlete KAI-2.501
• Appointment Athlete KAI-2.501 o Search for a live cable. o Detection of the passage of hidden communications (metal pipelines, cable lines). o Preliminary detection of the distance to the place of damage. o Search for places of cable damage by acoustic method. o Search for places of cable damage by electromagnetic means. o Cable insulation test. o The presence of the "Friend-Foe" mode.
Produced in: Kolomna, Moscow region
Central Heating Unit Kit
Central Heating Unit Kit
The kit is designed to control the temperature and pressure of the coolant and archive the measured results for further documentation and analysis. The main purpose of the kit is to control the coolant parameter, monitor the pressure and pressure drop between the supply and return pipelines, and fix hydraulic shocks. Features of the CTP kit The CTP kit allows you to control the parameters of the coolant supply, temperature and pressure. The kit consists of a four-channel meter-recorder, which allows you to store 15,000 values in memory for each channel with an interval of 5 seconds. up to several hours, which allows you to take measurements and store data for up to 1 year. The CTP kit allows you to monitor temperature and pressure around the clock throughout the year, and if necessary, for a longer period. With the help of the CTP kit, we see all the dynamics of the development of the situation of changes in temperature and pressure of the coolant, including weekends (crimping, stopping, starting the heating network, operating modes). The kit allows you to increase the responsibility of personnel for compliance with technological regimes. There is a real-time indication that allows personnel to monitor the parameters of the supplied coolant. A set of TTP is usually installed at the border of responsibility, i.e. at the point where, according to the contract, the supplier is obliged to supply a certain amount of coolant with a specific temperature and pressure parameters.
Produced in: Kolomna, Moscow region
Immitance Broadband Analyzer E7-28
Immitance Broadband Analyzer E7-28
Technical specifications: Extended frequency range 25 Hz–10 MHz The basic error is ±0.1 % The level of the measuring signal is 5 mV – 1 V S.K.z. Offset voltage (0 – 40) V The discreteness of the operating frequency setting is 1 Hz Graphical analysis of measured values in a given frequency range USB 2.0 interface
MNIPI
Minsk
Produced in: Belarus, Minsk
Verification module PM-3
Verification module PM-3
The composition of the PM-3 verification module: Frequency comparator CHK7-1011; Universal frequency meter Ch3-86A; Universal voltmeter V7-79; Absorbed power wattmeter M3-108-2; High-frequency signal generator G4-229; High-frequency signal generator G4-230; Generator of test pulses G9-1A; Oscilloscope S1-177; DC power supply B5-79/1; Electronic switchboard of RF signals; AC power source B2-7 (2 pcs.); PC, printer; Basic load-bearing structures (BNC). Technical specifications Measurement ranges of time-frequency parameters of signals: Continuous oscillation frequency from 0.005 Hz to 17.85 GHz Pulse repetition rate from 0.01 Hz to 100 MHz The carrier frequency of the IM signal is from 100 MHz to 17.85 GHz Pulse duration from 10 ns to 1000 s Time interval from 0 to 1000 s Nominal values of the frequency of the studied signals are 2,048; 5,0; 10,0; 10,24 MHz Measurement errors of time-frequency parameters of signals: Frequency of continuous oscillations ± (2,4·10-10 - 4·10-3) Pulse repetition rate ± (2·10-7 - 2·10-3) The carrier frequency of the IM signal is ± 2·10-7 Pulse duration ± (1 - 200) ns Time interval ± (1 - 200) ns The relative deviation of the frequency of the studied signal from the reference frequency ± (5·10-13 - 2·10-12) Frequency of continuous oscillations ± (3·10-11 – 1,1·10-5) Pulse repetition rate ± (2·10-11 – 6·10-5) Carrier frequency of the IM signal ± (3·10-11 – 1,1·10-5) Pulse duration ± (1·10-8 – 7,2·10-4) Time interval ± (2·10-10 – 7,2·10-4) Nominal values of the reference signal frequency ± (2·10-11 – 2,4·10-10) General technical characteristics: The area occupied by the module is 8-12 m2 Weight, not more than 327 kg Power supply voltage from 198 to 242 V frequency (50 ± 0.5) Hz Power consumption, no more than 2400 VA
Produced in: Moscow
Installation of pollution control of personnel RZBA-07D
Installation of pollution control of personnel RZBA-07D
Purpose: measuring the level of contamination of hands, feet (shoes) and clothing of personnel with beta-active substances and signaling when exceeding permissible levels monitoring the level of contamination with alpha-emitting radionuclides monitoring the contamination of personnel at nuclear power plants, nuclear fuel cycle enterprises (NFC), radiological laboratories, other enterprises and institutions using radioactive substances.
Doza
Zelenograd
Produced in: Moscow
Voltage converter V9-26
Voltage converter V9-26
Together with the conversion unit, a network AC-DC adapter module is supplied, as well as an intermediate power supply module.
NNPO im. M.V.Frunze
Nizhny Novgorod
Produced in: Nizhny Novgorod