Metrology

528 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 23
    Applying
    Loading...
  • 196
    Names
    Loading...
  • 54
    Manufacturer
    Loading...
  • 33
    Made in
    Loading...
  • 50
    Additional
    Loading...
View:
528 products
Search and diagnostic complex for finding cable damage by acoustic and induction method Athlete KAI-2.1001
Search and diagnostic complex for finding cable damage by acoustic and induction method Athlete KAI-2.1001
Appointment Athlete KAI-2.1001 • Determination of the type of damage and the distance to the place of damage to the cable. • Tracing a cable line up to 10 km. • Determination of cable depth up to 6 m. • Troubleshooting of cable lines by induction method. • Troubleshooting of cable lines by acoustic method. • Cable insulation testing.
Produced in: Kolomna, Moscow region
VD-3.6×1.8
VD-3.6×1.8
A flexible waveguide is a piece of high-quality dielectric, which ends with transitions to standard waveguides with flanges. For ease of operation, the waveguide is protected by an elastic shell. Basic properties Manufacturability of the connection; Small losses and VSWR; Economy. Operating conditions Operating temperature range from 5 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 3.6×1.8 Flange type according to GOST RV 51914-2002 Frequency range, GHz 53.57-78.33 VSWR 1.25 Losses, 2.5 dB Length, mm* 500
Produced in: Moscow
 Electronic Stopwatch-Meter IVPR-53SCH
Electronic Stopwatch-Meter IVPR-53SCH
from 40 940 ₽
The electronic stopwatch - time parameter meter IVPR-53SCH is a panel device for monitoring and measuring the time parameters of relays, switches and switches of electrical equipment, relay protection, automation and telemechanics.
NPP "ELEKTRONNYE PRIBORY"
Naberezhnye Chelny
Produced in: Tatarstan, Naberezhnye Chelny
MI-10X Magnetic Indicator
MI-10X Magnetic Indicator
from 17 000 ₽
Distinctive features. Compactness Autonomy Maximum ease of handling Energy saving mode Technical specifications Indication of induction levels, MT,: weak magnetization 0...2 average magnetization 2...10 strong magnetization more than 10 Power supply 1 accumulator unit or PP3 battery Current consumption, mA, no more than 8 Operating temperature range, °C -30...+50 Dimensions of the electronic unit, mm 90x50x32 Dimensions of the converter, mm 14x50
Produced in: Moscow
Wireless set for measuring the temperature of ferrous metal melts with logging function
Wireless set for measuring the temperature of ferrous metal melts with logging function
from 86 400 ₽
The kit is designed to measure the temperature of ferrous metal melts. It consists of a digital contact thermometer TK-5.27 complete with a submersible high-temperature probe, designed to measure the temperature of metal melts in the range of +600 ° C ... +1800 ° C. The digital contact thermometer TK-5.27 is equipped with the function of recording measurements in the device's memory, followed by transferring data to a computer and providing reports in the form of tables and graphs. To measure the temperatures of metal melts, disposable thermocouples of the PPR (B) type with a protective tube length of no more than 900 mm are used. The kit is adapted to the replacement blocks of EVRAZTEMP ET-V-09-00. •
Produced in: Moscow
Atmas Dust Analyzer
Atmas Dust Analyzer
from 258 900 ₽
during the control of maximum permissible concentrations in atmospheric air, in the air of the working area, during technological control of air purity of objects for various purposes, in the air of the sanitary protection zone, industrial emissions, emissions into the atmosphere.For measurements at low temperatures, an isothermal (thermo) bag can be included in the standard package at the request of the Customer for an additional fee.
Produced in: Moscow
Digital oscilloscope S8-52
Digital oscilloscope S8-52
Designed to study and measure the parameters of electrical signals in the frequency band from 0 to 120 MHz. Technical specifications: Number of channels 2 120 MHz bandwidth Sampling rate 250 MHz Equivalent sampling rate of 10 GHz Rise time of PH <= 2.9 ns Input active resistance (1±0.02) Mom Input capacitance <= 25 pF 120 MHz bandwidth 2 channels, external synchronization input Vertical sensitivity 2 mV/div Sampling rate up to 250 Mbps, in real time Recording length up to 16K counts in each channel Color LCD screen with LED backlight Cursor and automatic measurements USB and RS-232 interface
MNIPI
Minsk
Produced in: Belarus, Minsk
Measuring antenna P6-61
Measuring antenna P6-61
Technical specifications: Frequency range (26.0 - 300) MHz SWR < 2 The limit of permissible error of the antenna coefficient, not more than ± 2.0 dB Orthogonal polarization signal level -20 dB Ambient air temperature from - 50 to + 60 Relative humidity of 95 % at + 35 ° C Overall dimensions (HxWxD) 145x75x1720 mm Weight 0.7 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
HUMAN RADIATION SPECTROMETERS SKG‑AT1322, SKG‑AT1322/1
HUMAN RADIATION SPECTROMETERS SKG‑AT1322, SKG‑AT1322/1
Flexible software control of the spectrometer functions, the formation of a database and a report on the results of the survey Express control capacity - 15 people per hour The possibility of sharing AT1316(AT1316A) and AT1322(AT1322/1) The possibility of accommodation in a minibus as part of a mobile radiation control laboratory
Produced in: Belarus, Minsk
High-frequency signal generator G4-227
High-frequency signal generator G4-227
The generator is capable of operating both independently and as part of automated measuring systems with USB and IEEE-488 (CPC) interfaces. Technical specifications Frequency range from 9 kHz to 6 GHz Frequency tuning discreteness of 1 Hz The main error of the frequency setting is ± 3x10-7 Hz The range of setting the output signal power level at the main output is from minus 10 to 13 dBm The basic error of setting the reference power level is ± (0.5 – 1.0) dB Instability of the output signal power level for any 15-minute time interval of no more than 0.1 dB Metrological characteristics of the generator in the FM operation mode: - frequency range of the modulating signal from 1 to 100 kHz - frequency deviation setting range (taking into account the carrier frequency value) from 12.5 to 4000 kHz - the main error of the frequency deviation setting is ± (20 – 25)% Metrological characteristics of the generator in AM operation mode: - frequency range of the modulating signal from 0.05 to 5.0 kHz - the range of setting the amplitude modulation coefficient from 1 to 100 % - the basic error of setting the amplitude modulation coefficient ± (0.25 M + 0.2)% Metrological characteristics of the generator in the IM operation mode: - the duration range of modulating pulses from 300 ns to 20 s - the range of the modulating pulse repetition period from 340 ns to 30 s - the difference in the duration of the output RF pulses from the duration of the modulating pulses ± 200 ns Operating temperature range from minus 10 to 40 °C AC power supply 220 V, 50 Hz Power consumption, not more than 100 VA Overall dimensions, mm 498x136x487 Weight, not more than 13 kg
Produced in: Moscow
Dosimeter-radiometer ISS-15D "Bullfinch"
Dosimeter-radiometer ISS-15D "Bullfinch"
Dosimeter is a gamma-beta radiation radiometer for working in "dirty" conditions. Allows you to switch modes and take measurements in conditions of radioactive contamination. Measurement of the beta radiation flux density is carried out with automatic subtraction of the gamma radiation background. Purpose: measurement of the ambient dose equivalent of H*(10) gamma radiation; measurement of ambient dose equivalent of H*(10) gamma radiation; measurement of beta particle flux density; estimation of the counting rate with combined measurements of gamma and beta radiation.
Doza
Zelenograd
Produced in: Moscow