Search

3941 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 550
    Item names
    Loading...
  • 132
    Manufacturer
    Loading...
  • 59
    Made in
    Loading...
  • 109
    Additional
    Loading...
View:
3941 products
Vacuum drying cabinet SNVS-145/3,5
Vacuum drying cabinet SNVS-145/3,5
They are designed for carrying out various technological processes at temperatures from 40 to 500 oC, in vacuum up to 1x10−3 mmHg, or in an inert gas of high purity. They are used for drying, light annealing, aging, low and medium tempering in an oxidizing environment, degassing of ferrous and non-ferrous metals (including copper and copper alloys), or any other materials processed under similar conditions. The program setting of heat treatment modes including vacuuming, high purity inert gas intake with repeated vacuuming allows heating in an oxidizing environment with high purity of the surfaces of the processed parts, without scale formation and oxidation
Produced in: Tula
Second Mark Shaper Module
Second Mark Shaper Module
Pulse duration: ......10-15 microseconds The duration of the leading edge of the pulse:......no more than 20 ns Pulse amplitude: ...... at least 3V at a load of 50 ohms
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
Wall-mounted high table LAB-PRO SPKv 150.80.90 KG
Wall-mounted high table LAB-PRO SPKv 150.80.90 KG
Combined work surface: main countertop - KG (porcelain stoneware), 650 mm deep / auxiliary countertop made of TRESPA material with a depth of 150 mm Length, mm: 1500 Depth, mm: 800 Height, mm: 900 BASIC EQUIPMENT The base is a collapsible frame made of rectangular steel profile, painted with powder paint (RAL 7035) with the texture of shagreen leather Hidden fasteners Two easily removable rear screens (RAL 7035) and one non-removable (RAL 5023) Rear side boxes Adjustable supports (0-40 mm)
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Island high table LAB-PRO SOKv 180.150.90 KG-ESS
Island high table LAB-PRO SOKv 180.150.90 KG-ESS
Island table Combined work surface: main table top KG-ESS 650mm deep / auxiliary table top made of TRESPA material 200 mm deep / main table top KG-ESS 650mm deep Length, mm: 1800 Depth, mm: 1500 Height, mm: 900 BASIC EQUIPMENT The base is a collapsible metal frame made of rectangular steel profile, painted with powder paint (RAL 7035) with the texture of shagreen leather Four easily removable screens (RAL 7035) and two non-removable (RAL 5023) Hidden fasteners Adjustable supports (0-40 mm) A set of end boxes-plugs
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Wall-mounted table LAB-1200 PFM
Wall-mounted table LAB-1200 PFM
EQUIPMENT rack support racks – aluminum profile painted with powder paint (RAL 1001) top panel with a depth of 190mm – metal painted with powder paint (RAL 1001)
LOIP
Saint Petersburg
Produced in: Saint Petersburg
NV-800 SCb Anti-vibration table for centrifuge (860×860×750)
NV-800 SCb Anti-vibration table for centrifuge (860×860×750)
from 19 476 ₽
The NV-800 SCb is a large specialized laboratory table with a damping concrete slab on a sand cushion. It is designed to accommodate centrifuges, sieves and other devices that vibrate strongly during operation. Dimensions when assembled: 860×860×750 mm. The table has a reinforced metal frame. The main countertop has a built-in drawer open from above, which contains a sand cushion. It is closed with a heavy concrete slab, which is attached to a second, smaller countertop. The sand cushion and the concrete base of the second countertop provide good protection against vibrations. The size of the anti-vibration countertop: 660×660 mm. Like the main countertop, it is made of chipboard, and visually they do not differ from each other. The table has a metal frame painted with white powder paint. The side laminated panels (chipboard with a thickness of 16 mm) are edged with a durable PVC edge with a thickness of 2 mm, which increases their impact resistance and mechanical strength. The legs of the table are adjustable in height within two centimeters, allowing you to place it even on a rather uneven floor.
NV LAB
Moscow
Produced in: Moscow, Moscow region
KRP-UR Mobile radiographic cabinet (Fluorograph)
KRP-UR Mobile radiographic cabinet (Fluorograph)
The cabinet is designed for operation at outdoor air temperatures from minus 40°C to plus 40°C.
Produced in: Podolsk
Profile gasket without support ring
Profile gasket without support ring
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
Produced in: Kazan
LB63 Laboratory bath
LB63 Laboratory bath
It is intended for thermostating samples in glasses, flasks and other laboratory utensils in cases where high accuracy of temperature maintenance is not required and good uniformity of the temperature field in the working volume is not needed. The operating temperature range is +5...+200 °C. Six workstations with a diameter of 110 mm with five steel O-rings. Stamped steel tub with a volume of 25 liters and a depth of 160 mm. The volume of the bath is 25 liters Overall dimensions 560x370x460 mm The open part of the bath is 500x290 mm Bath depth 160 mm Weight 16 kg Power consumption 2.5 kW
Produced in: Tomsk
AC voltage source B2-7
AC voltage source B2-7
The AC voltage source B2-7 is intended to provide devices and equipment with a stabilized AC voltage during the development, production, operation and repair of electronic devices. Main properties: Provides protection against overload and short circuits at the output. Has a light indication: - overload and short circuit protection tripping; - incorrect connection of the power supply line to B2-7. Technical specifications The nominal value of the output voltage (SKZ) 220 V The nominal value of the input and output voltage frequency is 50 Hz Output electrical power, not less than 1000 VA The main error in setting the output voltage is ± 2.2 V Additional error in setting the output voltage caused by a deviation of the input voltage by ± 10% from the nominal value of 220 V ± 1.0 V Additional error in setting the output voltage caused by a change in the load current from the maximum value to zero ± 2.0 V Instability of the output voltage for any 10 minutes during 8 hours of continuous operation, no more than ± 2.0 V Operating temperature range from -10 to 50 °C AC power supply 220 V, 50 Hz Power consumption, no more than 1200 VA Overall dimensions, mm 240x128x349 Weight, not more than 6.5 kg
Produced in: Moscow
Electronic explosion-proof thermometer ExT-01/2-6
Electronic explosion-proof thermometer ExT-01/2-6
The thermometer sensor ExT-01/2-6 is made in the form of a fully submersible probe with a cable length of 6 meters. The thermometer has an explosion protection marking 0Ex ia IIB T4 Ga X and can be used in explosive zones 0, 1 and 2 of any classes of premises and outdoor installations in which the formation of explosive mixtures of categories IIA, IIB is possible. • Measurement range -50...+130 °C Minimum sensor immersion depth full immersion Overall dimensions of the electronic unit 135x65x40 mm Electronic unit weight 0.3 kg
Produced in: Tomsk
Metolab 202 Rockwell Hardness Tester
Metolab 202 Rockwell Hardness Tester
METOLAB 202 is a stationary automatic hardness tester designed to measure the hardness parameters of various materials and products on the A, B, C Rockwell scales and the HR15N, HR30N, HR30T, HR45N Super-Rockwell scales. The device has a large and bright display, which displays all the necessary service information, and is also equipped with a built-in mini-printer, so that it is possible to quickly print out the information received on paper. Other features of the METOLAB 202 hardness tester include a fully Russified menu, a wide range of measured values, as well as full compliance of measurements with current standards, including BS.EN 10109 and ISO716. The stationary METOLAB 202 hardness tester allows you to apply a loading force in 15, 30, 45, 60, 100, 150 kgf and preload 3 kgf, 10 kgf. The device is entered in the State Register of Measuring Instruments of the Russian Federation (GRSI) under the number 65128-16 and comes with a certificate of primary verification (on request). Regulatory and technical documents establishing requirements for the METOLAB 202 hardness tester: GOST 8.064-94 GSI. State verification scheme for hardness measuring instruments on the Rockwell and Super-Rockwell scales; GOST 9013-59 Metals and alloys. Rockwell hardness measurement method. Scales A, B, C; GOST 22975-78 Metals and alloys. Rockwell hardness measurement method at low loads (Super-Rockwell); GOST 23677-79 Hardness testers for metals. General technical requirements. Distinctive features of the stationary METOLAB 202 hardness tester: All measurements take place in fully automatic mode; The ability to set the upper and lower measurement limits, audible alarm when the results exceed the set values; Opportunity to process statistical data – calculation of minimum/average/maximum values, as well as other functions; Conversion of the obtained results into the Vickers, Brinell and Super-Rockwell scales; Correction for curvature of cylindrical and spherical parts; Simple and intuitive interface in Russian. Basic package of delivery: Stationary Metolab 202 Rockwell hardness tester; Indenter with a ball (1.5875 mm) - 1 pc.; Conical diamond indenter (120°) - 1 pc.; Flat table SP1 (60 mm); V-shaped prismatic table SRP1 (40 mm); Rockwell and Super-Rockwell Hardness Measures; User Manual.
Metolab
Moscow
Produced in: Moscow